Je něco špatně v tomto záznamu ?
Hydrosilated silica-based columns: the effects of mobile phase and temperature on dual hydrophilic-reversed-phase separation mechanism of phenolic acids
J. Soukup, P. Jandera,
Jazyk angličtina Země Nizozemsko
Typ dokumentu časopisecké články, práce podpořená grantem
- MeSH
- acetonitrily chemie MeSH
- cholesterol chemie MeSH
- chromatografie kapalinová přístrojové vybavení metody MeSH
- chromatografie s reverzní fází MeSH
- hydrofobní a hydrofilní interakce MeSH
- hydroxybenzoáty izolace a purifikace MeSH
- oxid křemičitý chemie MeSH
- teplota MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH
The effects of mobile phase composition and of temperature on the retention behavior of phenolic acids were studied on 4 hydrosilated (type C silica) based columns in buffered aqueous acetonitrile, both in the aqueous normal phase (HILIC) and in the reversed-phase mobile phase range. The UDC cholesterol and the C₁₈ bidentate columns show significant reversed phase and normal-phase retention mechanisms, whereas very weak retention in the reversed-phase mode was observed on the silica hydride and the Diamond hydride columns. The concentration effects of the aqueous acetate buffer over the full mobile phase (HILIC and RP) composition range can be described by a simple four-parameter equation. At increasing temperature, the retention times and peak widths decrease both in the aqueous normal phase and in the reversed phase mobile phase range. Linear van't Hoff log k versus 1/T plots were observed, indicating a single retention mechanism predominating in the highly organic (HILIC), like in highly aqueous (RP) mobile phase ranges. Besides the type of the stationary phase, the separation selectivity of phenolic acids strongly depends on temperature and on the mobile phase composition. From among the 4 hydrosilated columns compared in this work, the UDC cholesterol column has high temperature stability (up to 100 °C) and is most suitable for selective and efficient separations of phenolic acids both in the HILIC and in the RP modes.
Citace poskytuje Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc12024410
- 003
- CZ-PrNML
- 005
- 20121207115827.0
- 007
- ta
- 008
- 120815s2012 ne f 000 0#eng||
- 009
- AR
- 024 7_
- $a 10.1016/j.chroma.2011.06.077 $2 doi
- 035 __
- $a (PubMed)21782183
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a ne
- 100 1_
- $a Soukup, Jan $u Department of Analytical Chemistry, Faculty of Chemical Technology, University of Pardubice, Studentská 573, CZ 53210 Pardubice, Czech Republic.
- 245 10
- $a Hydrosilated silica-based columns: the effects of mobile phase and temperature on dual hydrophilic-reversed-phase separation mechanism of phenolic acids / $c J. Soukup, P. Jandera,
- 520 9_
- $a The effects of mobile phase composition and of temperature on the retention behavior of phenolic acids were studied on 4 hydrosilated (type C silica) based columns in buffered aqueous acetonitrile, both in the aqueous normal phase (HILIC) and in the reversed-phase mobile phase range. The UDC cholesterol and the C₁₈ bidentate columns show significant reversed phase and normal-phase retention mechanisms, whereas very weak retention in the reversed-phase mode was observed on the silica hydride and the Diamond hydride columns. The concentration effects of the aqueous acetate buffer over the full mobile phase (HILIC and RP) composition range can be described by a simple four-parameter equation. At increasing temperature, the retention times and peak widths decrease both in the aqueous normal phase and in the reversed phase mobile phase range. Linear van't Hoff log k versus 1/T plots were observed, indicating a single retention mechanism predominating in the highly organic (HILIC), like in highly aqueous (RP) mobile phase ranges. Besides the type of the stationary phase, the separation selectivity of phenolic acids strongly depends on temperature and on the mobile phase composition. From among the 4 hydrosilated columns compared in this work, the UDC cholesterol column has high temperature stability (up to 100 °C) and is most suitable for selective and efficient separations of phenolic acids both in the HILIC and in the RP modes.
- 650 _2
- $a acetonitrily $x chemie $7 D000097
- 650 _2
- $a cholesterol $x chemie $7 D002784
- 650 _2
- $a chromatografie kapalinová $x přístrojové vybavení $x metody $7 D002853
- 650 _2
- $a chromatografie s reverzní fází $7 D056148
- 650 _2
- $a hydrofobní a hydrofilní interakce $7 D057927
- 650 _2
- $a hydroxybenzoáty $x izolace a purifikace $7 D062385
- 650 _2
- $a oxid křemičitý $x chemie $7 D012822
- 650 _2
- $a teplota $7 D013696
- 655 _2
- $a časopisecké články $7 D016428
- 655 _2
- $a práce podpořená grantem $7 D013485
- 700 1_
- $a Jandera, Pavel
- 773 0_
- $w MED00004962 $t Journal of chromatography. A $x 1873-3778 $g Roč. 1228(2012), s. 125-34
- 856 41
- $u https://pubmed.ncbi.nlm.nih.gov/21782183 $y Pubmed
- 910 __
- $a ABA008 $b sig $c sign $y m
- 990 __
- $a 20120815 $b ABA008
- 991 __
- $a 20121207115902 $b ABA008
- 999 __
- $a ok $b bmc $g 946558 $s 781738
- BAS __
- $a 3
- BAS __
- $a PreBMC
- BMC __
- $a 2012 $b 1228 $d 125-34 $i 1873-3778 $m Journal of chromatography. A, Including electrophoresis and other separation methods $n J Chromatogr A $x MED00004962
- LZP __
- $a Pubmed-20120815/12/02