-
Something wrong with this record ?
Strip-based immunoassay for rapid detection of thiabendazole
M. Blazková, P. Rauch, L. Fukal,
Language English Country England, Great Britain
Document type Comparative Study, Evaluation Study, Journal Article, Research Support, Non-U.S. Gov't
- MeSH
- Biosensing Techniques instrumentation standards statistics & numerical data MeSH
- Enzyme-Linked Immunosorbent Assay MeSH
- Immunoassay instrumentation standards statistics & numerical data MeSH
- Colloids MeSH
- Food Contamination analysis MeSH
- Humans MeSH
- Maximum Allowable Concentration MeSH
- Beverages analysis MeSH
- Fruit chemistry MeSH
- Antibodies MeSH
- Pesticide Residues analysis immunology MeSH
- Thiabendazole analysis immunology MeSH
- Carbon MeSH
- Animals MeSH
- Check Tag
- Humans MeSH
- Animals MeSH
- Publication type
- Journal Article MeSH
- Evaluation Study MeSH
- Research Support, Non-U.S. Gov't MeSH
- Comparative Study MeSH
There is increased interest in the investigation and implementation of rapid screening methods for detection of pesticide residues. This study reports development of an immunostrip test for thiabendazole detection based on indirect competitive principle using carbon particles as a label. Nitrocellulose membrane strip was coated with a thiabendazole-protein conjugate in the defined test zone. In flow of an antibody-carbon complex and thiabendazole along the strip, the intensity of black colour formed in the test line reflected the thiabendazole concentration and semi-quantitative estimation could be carried out visually. The optimized test was accomplished within 10 min and the visual detection limit was achieved 0.25 ng mL(-1) of standard sample. Moreover, immunostrip was evaluated quantitatively using scanning densitometry. Based on standard curve, the detection limit of the proposed test was as low as 0.08+/-0.03 ng mL(-1) with an IC(50) value of 0.60+/-0.08 ng mL(-1) and a linear working range of 0.11-4.13 ng mL(-1). Results of testing precision, stability, and specificity demonstrated that the assay provided a reliable performance. This immunostrip was applied to analysis of spiked fruit juices in range of 0.05-5 mg L(-1). Matrix interferences were avoided by simple dilution of samples. Both visual and instrumental evaluations indicated a good agreement with results obtained by ELISA. Recoveries from juices were from 81.9 to 123.6% and relative standard deviations ranged from 9.9 to 19.3%. The developed strip offers potential as a useful rapid and simple method for screening of thiabendazole in fruit juices at levels far below the maximum residue limits.
References provided by Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc12025866
- 003
- CZ-PrNML
- 005
- 20121206120813.0
- 007
- ta
- 008
- 120817e20100224enk f 000 0#eng||
- 009
- AR
- 024 7_
- $a 10.1016/j.bios.2010.02.011 $2 doi
- 035 __
- $a (PubMed)20236817
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a enk
- 100 1_
- $a Krausová, Martina, $d 1979- $7 ntk20181014587 $u Department of Biochemistry and Microbiology, Faculty of Food and Biochemical Technology, Institute of Chemical Technology, Technická 3, 16628 Prague, Czech Republic.
- 245 10
- $a Strip-based immunoassay for rapid detection of thiabendazole / $c M. Blazková, P. Rauch, L. Fukal,
- 520 9_
- $a There is increased interest in the investigation and implementation of rapid screening methods for detection of pesticide residues. This study reports development of an immunostrip test for thiabendazole detection based on indirect competitive principle using carbon particles as a label. Nitrocellulose membrane strip was coated with a thiabendazole-protein conjugate in the defined test zone. In flow of an antibody-carbon complex and thiabendazole along the strip, the intensity of black colour formed in the test line reflected the thiabendazole concentration and semi-quantitative estimation could be carried out visually. The optimized test was accomplished within 10 min and the visual detection limit was achieved 0.25 ng mL(-1) of standard sample. Moreover, immunostrip was evaluated quantitatively using scanning densitometry. Based on standard curve, the detection limit of the proposed test was as low as 0.08+/-0.03 ng mL(-1) with an IC(50) value of 0.60+/-0.08 ng mL(-1) and a linear working range of 0.11-4.13 ng mL(-1). Results of testing precision, stability, and specificity demonstrated that the assay provided a reliable performance. This immunostrip was applied to analysis of spiked fruit juices in range of 0.05-5 mg L(-1). Matrix interferences were avoided by simple dilution of samples. Both visual and instrumental evaluations indicated a good agreement with results obtained by ELISA. Recoveries from juices were from 81.9 to 123.6% and relative standard deviations ranged from 9.9 to 19.3%. The developed strip offers potential as a useful rapid and simple method for screening of thiabendazole in fruit juices at levels far below the maximum residue limits.
- 650 _2
- $a zvířata $7 D000818
- 650 _2
- $a protilátky $7 D000906
- 650 _2
- $a nápoje $x analýza $7 D001628
- 650 _2
- $a biosenzitivní techniky $x přístrojové vybavení $x normy $x statistika a číselné údaje $7 D015374
- 650 _2
- $a uhlík $7 D002244
- 650 _2
- $a koloidy $7 D003102
- 650 _2
- $a ELISA $7 D004797
- 650 _2
- $a kontaminace potravin $x analýza $7 D005506
- 650 _2
- $a ovoce $x chemie $7 D005638
- 650 _2
- $a lidé $7 D006801
- 650 _2
- $a imunoanalýza $x přístrojové vybavení $x normy $x statistika a číselné údaje $7 D007118
- 650 _2
- $a maximální přípustná koncentrace $7 D008452
- 650 _2
- $a rezidua pesticidů $x analýza $x imunologie $7 D010573
- 650 _2
- $a thiabendazol $x analýza $x imunologie $7 D013827
- 655 _2
- $a srovnávací studie $7 D003160
- 655 _2
- $a hodnotící studie $7 D023362
- 655 _2
- $a časopisecké články $7 D016428
- 655 _2
- $a práce podpořená grantem $7 D013485
- 700 1_
- $a Rauch, Pavel, $d 1941- $7 nlk20030128619
- 700 1#
- $a Fukal, Ladislav. $7 _AN047149
- 773 0_
- $w MED00006627 $t Biosensors & bioelectronics $x 1873-4235 $g Roč. 25, č. 9 (20100224), s. 2122-8
- 856 41
- $u https://pubmed.ncbi.nlm.nih.gov/20236817 $y Pubmed
- 910 __
- $a ABA008 $b sig $c sign $y m
- 990 __
- $a 20120817 $b ABA008
- 991 __
- $a 20121206120847 $b ABA008
- 999 __
- $a ok $b bmc $g 947908 $s 783212
- BAS __
- $a 3
- BAS __
- $a PreBMC
- BMC __
- $a 2010 $b 25 $c 9 $d 2122-8 $e 20100224 $i 1873-4235 $m Biosensors & bioelectronics $n Biosens Bioelectron $x MED00006627
- LZP __
- $a Pubmed-20120817/10/03