Strip-based immunoassay for rapid detection of thiabendazole

M. Blazková, P. Rauch, L. Fukal,

. 2010 ; 25 (9) : 2122-8. [pub] 20100224

Language English Country England, Great Britain

Document type Comparative Study, Evaluation Study, Journal Article, Research Support, Non-U.S. Gov't

There is increased interest in the investigation and implementation of rapid screening methods for detection of pesticide residues. This study reports development of an immunostrip test for thiabendazole detection based on indirect competitive principle using carbon particles as a label. Nitrocellulose membrane strip was coated with a thiabendazole-protein conjugate in the defined test zone. In flow of an antibody-carbon complex and thiabendazole along the strip, the intensity of black colour formed in the test line reflected the thiabendazole concentration and semi-quantitative estimation could be carried out visually. The optimized test was accomplished within 10 min and the visual detection limit was achieved 0.25 ng mL(-1) of standard sample. Moreover, immunostrip was evaluated quantitatively using scanning densitometry. Based on standard curve, the detection limit of the proposed test was as low as 0.08+/-0.03 ng mL(-1) with an IC(50) value of 0.60+/-0.08 ng mL(-1) and a linear working range of 0.11-4.13 ng mL(-1). Results of testing precision, stability, and specificity demonstrated that the assay provided a reliable performance. This immunostrip was applied to analysis of spiked fruit juices in range of 0.05-5 mg L(-1). Matrix interferences were avoided by simple dilution of samples. Both visual and instrumental evaluations indicated a good agreement with results obtained by ELISA. Recoveries from juices were from 81.9 to 123.6% and relative standard deviations ranged from 9.9 to 19.3%. The developed strip offers potential as a useful rapid and simple method for screening of thiabendazole in fruit juices at levels far below the maximum residue limits.

References provided by Crossref.org

000      
00000naa a2200000 a 4500
001      
bmc12025866
003      
CZ-PrNML
005      
20121206120813.0
007      
ta
008      
120817e20100224enk f 000 0#eng||
009      
AR
024    7_
$a 10.1016/j.bios.2010.02.011 $2 doi
035    __
$a (PubMed)20236817
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a enk
100    1_
$a Krausová, Martina, $d 1979- $7 ntk20181014587 $u Department of Biochemistry and Microbiology, Faculty of Food and Biochemical Technology, Institute of Chemical Technology, Technická 3, 16628 Prague, Czech Republic.
245    10
$a Strip-based immunoassay for rapid detection of thiabendazole / $c M. Blazková, P. Rauch, L. Fukal,
520    9_
$a There is increased interest in the investigation and implementation of rapid screening methods for detection of pesticide residues. This study reports development of an immunostrip test for thiabendazole detection based on indirect competitive principle using carbon particles as a label. Nitrocellulose membrane strip was coated with a thiabendazole-protein conjugate in the defined test zone. In flow of an antibody-carbon complex and thiabendazole along the strip, the intensity of black colour formed in the test line reflected the thiabendazole concentration and semi-quantitative estimation could be carried out visually. The optimized test was accomplished within 10 min and the visual detection limit was achieved 0.25 ng mL(-1) of standard sample. Moreover, immunostrip was evaluated quantitatively using scanning densitometry. Based on standard curve, the detection limit of the proposed test was as low as 0.08+/-0.03 ng mL(-1) with an IC(50) value of 0.60+/-0.08 ng mL(-1) and a linear working range of 0.11-4.13 ng mL(-1). Results of testing precision, stability, and specificity demonstrated that the assay provided a reliable performance. This immunostrip was applied to analysis of spiked fruit juices in range of 0.05-5 mg L(-1). Matrix interferences were avoided by simple dilution of samples. Both visual and instrumental evaluations indicated a good agreement with results obtained by ELISA. Recoveries from juices were from 81.9 to 123.6% and relative standard deviations ranged from 9.9 to 19.3%. The developed strip offers potential as a useful rapid and simple method for screening of thiabendazole in fruit juices at levels far below the maximum residue limits.
650    _2
$a zvířata $7 D000818
650    _2
$a protilátky $7 D000906
650    _2
$a nápoje $x analýza $7 D001628
650    _2
$a biosenzitivní techniky $x přístrojové vybavení $x normy $x statistika a číselné údaje $7 D015374
650    _2
$a uhlík $7 D002244
650    _2
$a koloidy $7 D003102
650    _2
$a ELISA $7 D004797
650    _2
$a kontaminace potravin $x analýza $7 D005506
650    _2
$a ovoce $x chemie $7 D005638
650    _2
$a lidé $7 D006801
650    _2
$a imunoanalýza $x přístrojové vybavení $x normy $x statistika a číselné údaje $7 D007118
650    _2
$a maximální přípustná koncentrace $7 D008452
650    _2
$a rezidua pesticidů $x analýza $x imunologie $7 D010573
650    _2
$a thiabendazol $x analýza $x imunologie $7 D013827
655    _2
$a srovnávací studie $7 D003160
655    _2
$a hodnotící studie $7 D023362
655    _2
$a časopisecké články $7 D016428
655    _2
$a práce podpořená grantem $7 D013485
700    1_
$a Rauch, Pavel, $d 1941- $7 nlk20030128619
700    1#
$a Fukal, Ladislav. $7 _AN047149
773    0_
$w MED00006627 $t Biosensors & bioelectronics $x 1873-4235 $g Roč. 25, č. 9 (20100224), s. 2122-8
856    41
$u https://pubmed.ncbi.nlm.nih.gov/20236817 $y Pubmed
910    __
$a ABA008 $b sig $c sign $y m
990    __
$a 20120817 $b ABA008
991    __
$a 20121206120847 $b ABA008
999    __
$a ok $b bmc $g 947908 $s 783212
BAS    __
$a 3
BAS    __
$a PreBMC
BMC    __
$a 2010 $b 25 $c 9 $d 2122-8 $e 20100224 $i 1873-4235 $m Biosensors & bioelectronics $n Biosens Bioelectron $x MED00006627
LZP    __
$a Pubmed-20120817/10/03

Find record

Citation metrics

Loading data ...

Archiving options

Loading data ...