Detail
Article
Online article
FT
Medvik - BMC
  • Something wrong with this record ?

Fast HPLC method using ion-pair and hydrophilic interaction liquid chromatography for determination of phenylephrine in pharmaceutical formulations

M. Dousa, P. Gibala,

. 2010 ; 93 (5) : 1436-42.

Language English Country United States

Document type Journal Article

A rapid procedure based on a direct extraction and HPLC determination with fluorescence detection of phenylephrine in pharmaceutical sachets that include a large excess of paracetamol (65 + 1, w/w), ascorbic acid (5 + 1, w/w), and other excipients (aspartame and sucrose) was developed and validated. The final optimized chromatographic method for ion-pair chromatography used an XTerra RP18 column, 3 microm particle size, 50 x 3.0 mm id. The mobile phase consisted of a mixture of acetonitrile and buffer (10 mM sodium octane-1-sulfonate, adjusted with H3PO4 to pH 2.2; 200 + 800, v/v), with a constant flow rate of 0.3 mL/min. The separation was carried out at 30 degrees C, and the injection volume was 3 microL. Fluorescence detection was performed at excitation and emission wavelengths of 275 and 310 nm, respectively. The mobile phase parameters, such as the organic solvent fraction (acetonitrile) in mobile phase as an organic modifier, the concentration of sodium octane-1-sulfonate as a counter-ion, temperature, and pH of mobile phase, were studied. As an alternative to ion-pair chromatography, hydrophilic interaction liquid chromatography (HILIC) was investigated using a Luna HILIC column, 3 microm, 100 x 4.6 mm id. The mobile phase consisted of acetonitrile and buffer (5 mM potassium dihydrogen phosphate, adjusted with H3PO4 to pH 2.5; 750 + 250, v/v) at a flow rate of 0.8 mL/min. The separation was carried out at 25 degrees C, and the injection volume was 5 microL. The proposed method has an advantage of a very simple sample pretreatment, and is much faster than the currently utilized HPLC methods using gradient elution and UV detection. Commercial samples of sachets were successfully analyzed by the proposed HPLC method.

000      
00000naa a2200000 a 4500
001      
bmc12026070
003      
CZ-PrNML
005      
20121207113756.0
007      
ta
008      
120817s2010 xxu f 000 0#eng||
009      
AR
035    __
$a (PubMed)21140654
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a xxu
100    1_
$a Dousa, Michal $u Zentiva, k.s. Praha, U Kabelovny 130, 102 37 Praha 10, Czech Republic.
245    10
$a Fast HPLC method using ion-pair and hydrophilic interaction liquid chromatography for determination of phenylephrine in pharmaceutical formulations / $c M. Dousa, P. Gibala,
520    9_
$a A rapid procedure based on a direct extraction and HPLC determination with fluorescence detection of phenylephrine in pharmaceutical sachets that include a large excess of paracetamol (65 + 1, w/w), ascorbic acid (5 + 1, w/w), and other excipients (aspartame and sucrose) was developed and validated. The final optimized chromatographic method for ion-pair chromatography used an XTerra RP18 column, 3 microm particle size, 50 x 3.0 mm id. The mobile phase consisted of a mixture of acetonitrile and buffer (10 mM sodium octane-1-sulfonate, adjusted with H3PO4 to pH 2.2; 200 + 800, v/v), with a constant flow rate of 0.3 mL/min. The separation was carried out at 30 degrees C, and the injection volume was 3 microL. Fluorescence detection was performed at excitation and emission wavelengths of 275 and 310 nm, respectively. The mobile phase parameters, such as the organic solvent fraction (acetonitrile) in mobile phase as an organic modifier, the concentration of sodium octane-1-sulfonate as a counter-ion, temperature, and pH of mobile phase, were studied. As an alternative to ion-pair chromatography, hydrophilic interaction liquid chromatography (HILIC) was investigated using a Luna HILIC column, 3 microm, 100 x 4.6 mm id. The mobile phase consisted of acetonitrile and buffer (5 mM potassium dihydrogen phosphate, adjusted with H3PO4 to pH 2.5; 750 + 250, v/v) at a flow rate of 0.8 mL/min. The separation was carried out at 25 degrees C, and the injection volume was 5 microL. The proposed method has an advantage of a very simple sample pretreatment, and is much faster than the currently utilized HPLC methods using gradient elution and UV detection. Commercial samples of sachets were successfully analyzed by the proposed HPLC method.
650    _2
$a farmaceutická chemie $7 D002626
650    _2
$a vysokoúčinná kapalinová chromatografie $x metody $7 D002851
650    _2
$a stabilita léku $7 D004355
650    _2
$a limita detekce $7 D057230
650    _2
$a fenylefrin $x aplikace a dávkování $x analýza $x chemie $7 D010656
655    _2
$a časopisecké články $7 D016428
700    1_
$a Gibala, Petr
773    0_
$w MED00002515 $t Journal of AOAC International $x 1060-3271 $g Roč. 93, č. 5 (2010), s. 1436-42
856    41
$u https://pubmed.ncbi.nlm.nih.gov/21140654 $y Pubmed
910    __
$a ABA008 $b sig $c sign $y m
990    __
$a 20120817 $b ABA008
991    __
$a 20121207113830 $b ABA008
999    __
$a ok $b bmc $g 948112 $s 783416
BAS    __
$a 3
BAS    __
$a PreBMC
BMC    __
$a 2010 $b 93 $c 5 $d 1436-42 $i 1060-3271 $m Journal of AOAC International $n J AOAC Int $x MED00002515
LZP    __
$a Pubmed-20120817/10/04

Find record

Citation metrics

Loading data ...

Archiving options

Loading data ...