Contrast-enhanced MR angiography utilizing parallel acquisition techniques in renal artery stenosis detection

M. Slanina, J. Zizka, L. Klzo, M. Lojík,

. 2010 ; 75 (1) : e46-50.

Jazyk angličtina Země Irsko

Typ dokumentu časopisecké články

Perzistentní odkaz   https://www.medvik.cz/link/bmc12026509

Significant renal artery stenosis (RAS) is a potentially curable cause of renovascular hypertension and/or renal impairment. It is caused by either atherosclerosis or fibromuscular dysplasia. Correct and timely diagnosis remains a diagnostic challenge. MR angiography (MRA) as a minimally invasive method seems to be suitable for RAS detection, however, its diagnostic value widely differs in the literature (sensitivity 62-100% and specificity 75-100%). The aim of our prospective study was to compare the diagnostic value of contrast-enhanced MRA utilizing parallel acquisition techniques in the detection of significant RAS with digital subtraction angiography (DSA). A total of 78 hypertensive subjects with suspected renal artery stenosis were examined on a 1.5 Tesla MR system using a body array coil. Bolus tracking was used to monitor the arrival of contrast agent to the abdominal aorta. The MRA sequence parameters were as follows: TR 3.7 ms; TE 1.2 ms; flip angle 25 degrees; acquisition time 18s; voxel size 1.1 mm x1.0 mm x 1.1 mm; centric k-space sampling; parallel acquisition technique with acceleration factor of 2 (GRAPPA). Renal artery stenosis of 60% and more was considered hemodynamically significant. The results of MRA were compared to digital subtraction angiography serving as a standard of reference. Sensitivity and specificity of MRA in the detection of hemodynamically significant renal artery stenosis were 90% and 96%, respectively. Prevalence of RAS was 39% in our study population. Contrast-enhanced MRA with high spatial resolution offers sufficient sensitivity and specificity for screening of RAS.

Citace poskytuje Crossref.org

000      
00000naa a2200000 a 4500
001      
bmc12026509
003      
CZ-PrNML
005      
20121029120633.0
007      
ta
008      
120817s2010 ie f 000 0#eng||
009      
AR
024    7_
$a 10.1016/j.ejrad.2009.07.010 $2 doi
035    __
$a (PubMed)19671492
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a ie
100    1_
$a Slanina, Martin $7 xx0101054 $u Department of Radiology, Charles University Prague, Medical Faculty & Teaching Hospital in Hradec Králové, Sokolská 581, Hradec Králové 500 05, Czech Republic. slaninajicin@seznam.cz
245    10
$a Contrast-enhanced MR angiography utilizing parallel acquisition techniques in renal artery stenosis detection / $c M. Slanina, J. Zizka, L. Klzo, M. Lojík,
520    9_
$a Significant renal artery stenosis (RAS) is a potentially curable cause of renovascular hypertension and/or renal impairment. It is caused by either atherosclerosis or fibromuscular dysplasia. Correct and timely diagnosis remains a diagnostic challenge. MR angiography (MRA) as a minimally invasive method seems to be suitable for RAS detection, however, its diagnostic value widely differs in the literature (sensitivity 62-100% and specificity 75-100%). The aim of our prospective study was to compare the diagnostic value of contrast-enhanced MRA utilizing parallel acquisition techniques in the detection of significant RAS with digital subtraction angiography (DSA). A total of 78 hypertensive subjects with suspected renal artery stenosis were examined on a 1.5 Tesla MR system using a body array coil. Bolus tracking was used to monitor the arrival of contrast agent to the abdominal aorta. The MRA sequence parameters were as follows: TR 3.7 ms; TE 1.2 ms; flip angle 25 degrees; acquisition time 18s; voxel size 1.1 mm x1.0 mm x 1.1 mm; centric k-space sampling; parallel acquisition technique with acceleration factor of 2 (GRAPPA). Renal artery stenosis of 60% and more was considered hemodynamically significant. The results of MRA were compared to digital subtraction angiography serving as a standard of reference. Sensitivity and specificity of MRA in the detection of hemodynamically significant renal artery stenosis were 90% and 96%, respectively. Prevalence of RAS was 39% in our study population. Contrast-enhanced MRA with high spatial resolution offers sufficient sensitivity and specificity for screening of RAS.
650    _2
$a dospělí $7 D000328
650    _2
$a senioři $7 D000368
650    _2
$a algoritmy $7 D000465
650    _2
$a kontrastní látky $7 D003287
650    _2
$a ženské pohlaví $7 D005260
650    _2
$a lidé $7 D006801
650    _2
$a vylepšení obrazu $x metody $7 D007089
650    _2
$a interpretace obrazu počítačem $x metody $7 D007090
650    _2
$a magnetická rezonanční angiografie $x metody $7 D018810
650    _2
$a mužské pohlaví $7 D008297
650    _2
$a lidé středního věku $7 D008875
650    _2
$a organokovové sloučeniny $x diagnostické užití $7 D009942
650    _2
$a obstrukce renální arterie $x diagnóza $7 D012078
650    _2
$a reprodukovatelnost výsledků $7 D015203
650    _2
$a senzitivita a specificita $7 D012680
650    _2
$a mladý dospělý $7 D055815
655    _2
$a časopisecké články $7 D016428
700    1_
$a Žižka, Jan
700    1_
$a Klzo, Ludovít $7 xx0081745
700    1_
$a Lojík, Miroslav, $d 1965- $7 xx0070973
773    0_
$w MED00009640 $t European journal of radiology $x 1872-7727 $g Roč. 75, č. 1 (2010), s. e46-50
856    41
$u https://pubmed.ncbi.nlm.nih.gov/19671492 $y Pubmed
910    __
$a ABA008 $b sig $c sign $y m
990    __
$a 20120817 $b ABA008
991    __
$a 20121029120634 $b ABA008
999    __
$a ok $b bmc $g 948551 $s 783855
BAS    __
$a 3
BAS    __
$a PreBMC
BMC    __
$a 2010 $b 75 $c 1 $d e46-50 $i 1872-7727 $m European journal of radiology $n Eur J Radiol $x MED00009640
LZP    __
$a Pubmed-20120817/10/04

Najít záznam

Citační ukazatele

Nahrávání dat ...

Možnosti archivace

Nahrávání dat ...