Comparative analysis of clinical outcomes obtained with a new diffractive multifocal toric intraocular lens implanted through two types of corneal incision

P. Mojzis, DP. Piñero, P. Studeny, J. Tomás, V. Korda, AB. Plaza, JL. Alió,

. 2011 ; 27 (9) : 648-57. [pub] 20110520

Jazyk angličtina Země Spojené státy americké

Typ dokumentu srovnávací studie, časopisecké články, multicentrická studie, práce podpořená grantem

Perzistentní odkaz   https://www.medvik.cz/link/bmc12028309

PURPOSE: To analyze and compare the clinical outcomes obtained after cataract surgery with the implantation of a new multifocal toric intraocular lens (IOL) using two different types of corneal incision. METHODS: Retrospective study including 64 eyes of 35 patients who underwent surgery with implantation of the AT LISA 909M multifocal toric IOL (Carl Zeiss Meditec) in 2 different ophthalmologic centers using different criteria for corneal incision size: sub-1.8 mm (micro-incision surgery [MICS] group) and 2.2 mm (mini-incision group). Visual, refractive, and corneal topographic outcomes were evaluated during 6-month follow-up. Additionally, refractive astigmatic changes were analyzed using the Alpins vectorial method. RESULTS: Significant reductions of refractive sphere and cylinder were observed postoperatively (P<.03), with associated visual improvements for near and distance (P<.01) in both groups. Mean postoperative magnitudes of difference vector, torque, and magnitude of error in the overall sample were 0.52±0.36 diopters (D), 0.36 ± 0.36 D, and 0.08 ± 0.38 D, respectively. A mean overcorrection of 4% in refractive astigmatism was found. Mean angle of error was 0.37± 5.50° and -4.51±13.16° for the MICS and mini-incision groups, respectively (P=.09). Significant positive correlations were found between the magnitudes of torque and difference vector (r=0.78, P<.01) as well as between the magnitude of torque and absolute angle of error (r=0.76, P<.01). CONCLUSIONS: Implantation of the AT LISA toric IOL using corneal incisions <2.2 mm provides excellent predictability for astigmatic correction.

Citace poskytuje Crossref.org

000      
00000naa a2200000 a 4500
001      
bmc12028309
003      
CZ-PrNML
005      
20121207122821.0
007      
ta
008      
120817e20110520xxu f 000 0#eng||
009      
AR
024    7_
$a 10.3928/1081597x-20110506-01 $2 doi
035    __
$a (PubMed)21598872
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a xxu
100    1_
$a Mojzis, Peter $u Eye Department, Regional Hospital, Havlickuv Brod, Czech Republic.
245    10
$a Comparative analysis of clinical outcomes obtained with a new diffractive multifocal toric intraocular lens implanted through two types of corneal incision / $c P. Mojzis, DP. Piñero, P. Studeny, J. Tomás, V. Korda, AB. Plaza, JL. Alió,
520    9_
$a PURPOSE: To analyze and compare the clinical outcomes obtained after cataract surgery with the implantation of a new multifocal toric intraocular lens (IOL) using two different types of corneal incision. METHODS: Retrospective study including 64 eyes of 35 patients who underwent surgery with implantation of the AT LISA 909M multifocal toric IOL (Carl Zeiss Meditec) in 2 different ophthalmologic centers using different criteria for corneal incision size: sub-1.8 mm (micro-incision surgery [MICS] group) and 2.2 mm (mini-incision group). Visual, refractive, and corneal topographic outcomes were evaluated during 6-month follow-up. Additionally, refractive astigmatic changes were analyzed using the Alpins vectorial method. RESULTS: Significant reductions of refractive sphere and cylinder were observed postoperatively (P<.03), with associated visual improvements for near and distance (P<.01) in both groups. Mean postoperative magnitudes of difference vector, torque, and magnitude of error in the overall sample were 0.52±0.36 diopters (D), 0.36 ± 0.36 D, and 0.08 ± 0.38 D, respectively. A mean overcorrection of 4% in refractive astigmatism was found. Mean angle of error was 0.37± 5.50° and -4.51±13.16° for the MICS and mini-incision groups, respectively (P=.09). Significant positive correlations were found between the magnitudes of torque and difference vector (r=0.78, P<.01) as well as between the magnitude of torque and absolute angle of error (r=0.76, P<.01). CONCLUSIONS: Implantation of the AT LISA toric IOL using corneal incisions <2.2 mm provides excellent predictability for astigmatic correction.
650    _2
$a dospělí $7 D000328
650    _2
$a astigmatismus $x patofyziologie $7 D001251
650    _2
$a rohovka $x chirurgie $7 D003315
650    _2
$a rohovková topografie $7 D019781
650    _2
$a ženské pohlaví $7 D005260
650    _2
$a následné studie $7 D005500
650    _2
$a lidé $7 D006801
650    _2
$a implantace nitrooční čočky $7 D019654
650    _2
$a nitrooční čočky $7 D007910
650    _2
$a mužské pohlaví $7 D008297
650    _2
$a mikrochirurgie $x metody $7 D008866
650    _2
$a lidé středního věku $7 D008875
650    _2
$a fakoemulzifikace $x metody $7 D018918
650    _2
$a protézy - design $7 D011474
650    _2
$a refrakce oka $x fyziologie $7 D012029
650    _2
$a retrospektivní studie $7 D012189
650    _2
$a výsledek terapie $7 D016896
650    _2
$a zraková ostrost $x fyziologie $7 D014792
650    _2
$a mladý dospělý $7 D055815
655    _2
$a srovnávací studie $7 D003160
655    _2
$a časopisecké články $7 D016428
655    _2
$a multicentrická studie $7 D016448
655    _2
$a práce podpořená grantem $7 D013485
700    1_
$a Piñero, David P
700    1_
$a Studeny, Pavel
700    1_
$a Tomás, Javier
700    1_
$a Korda, Vladimir
700    1_
$a Plaza, Ana B
700    1_
$a Alió, Jorge L $7 gn_A_00004283
773    0_
$w MED00002927 $t Journal of refractive surgery (Thorofare, N.J. : 1995) $x 1081-597X $g Roč. 27, č. 9 (20110520), s. 648-57
856    41
$u https://pubmed.ncbi.nlm.nih.gov/21598872 $y Pubmed
910    __
$a ABA008 $b sig $c sign $y m
990    __
$a 20120817 $b ABA008
991    __
$a 20121207122856 $b ABA008
999    __
$a ok $b bmc $g 950351 $s 785655
BAS    __
$a 3
BAS    __
$a PreBMC
BMC    __
$a 2011 $b 27 $c 9 $d 648-57 $e 20110520 $i 1081-597X $m Journal of refractive surgery $n J Refract Surg $x MED00002927
LZP    __
$a Pubmed-20120817/11/04

Najít záznam

Citační ukazatele

Pouze přihlášení uživatelé

Možnosti archivace

Nahrávání dat ...