TEP kyčle Plasmacup-Bicontact: výsledky s minimálně 10letým sledováním
[Cementless Plasmacup-Bicontact total hip arthroplasty. Results of a minimum of ten-year follow-up]

J. Špička, L. Radová, J. Gallo

. 2012 ; 79 (4) : 317-323.

Jazyk čeština Země Česko

Perzistentní odkaz   https://www.medvik.cz/link/bmc12029600

Digitální knihovna NLK
Zdroj

E-zdroje Online

NLK Free Medical Journals od 2006

PURPOSE OF THE STUDY The aim of the study was to analyse the long-term clinical and radiographic results of total hip arthroplasty (THA) with the Bicontact-Plasmacup prosthesis. MATERIAL AND METHODS In this retrospective observational study, 34 consecutive patients undergoing Bicontact-Plasmacup THA between August 1998 and July 2000 were evaluated. The group included 15 women and 19 men with an average age of 56 years (30 to 67 years). The mean ? SD of follow-up was 132 ? 9 months (122 to 149 months). Patients' satisfaction with the treatment outcome and selected clinical and radiographic features were evaluated. The data were analysed using the concordance test, Spearman's correlation coefficient and chi-square test. RESULTS At the final follow-up, 94% of the interviewed patients reported satisfaction with the surgery outcome. The mean Harris score was 93 (67 to 98) points, with excellent or very good results in 91% of the patients. Compared with the post-operative radiographs, the mean ? SD value for vertical migration of the acetabular cup was 2.43 ? 3.21 mm (0 to 12 mm) and that for horizontal migration was 0.35 ? 1.0 mm (0 to 4.3 mm). The mean stem subsidence was by 3.87 mm (range, 0.36 to 21.11 mm; SD 4.03). At the final follow-up, all implants showed radiographic stability and absence of radiolucent lines. Early acetabular osteolysis was detected in two patients (5.9 %). In 19 patients (56%) a change in bone architecture, similar to alterations due to weight-bearing adaptation, was seen around the cup following surgery. The stress shielding effect of the femoral component was recorded in 79%, bypass phenomenon in 41 % and pedestal formation under the apex of the stem in 18% of the patients. The mean rate of polyethylene wear measured by the Dorr and Wan method was 0.106 mm per year (range, 0.00 to 0.267 mm) or it was 0.078 mm per year (0.00 to 0.19 mm) when assessed by a modification of the method described by Kang et al. DISCUSSION The clinical and radiographic findings presented here are in accordance with the relevant literature data. This implant design is associated with a relatively infrequent osteolysis around the cup probably due to a low wear rate of polyethylene and a stable polyethylene liner-metal cup interface. Based on this work and some other studies it can be concluded that a post-operative migration of several millimetres is compatible with a long-term, stable cementless THA. CONCLUSIONS The Bicontact-Plasmacup THA meets the National Institute for Health and Clinical Excellence (NICE) criteria for a very good implant (ten-year survival rate of over 90%). At 10 years after surgery, however, the first signs of complaints about surgery outcome // dissatisfaction with surgery outcomes were recorded. This may, at least partly, be related to aseptic loosening which is one of the symptoms of particle disease.

Cementless Plasmacup-Bicontact total hip arthroplasty. Results of a minimum of ten-year follow-up

Obsahuje 5 tabulek

Bibliografie atd.

Literatura

000      
00000naa a2200000 a 4500
001      
bmc12029600
003      
CZ-PrNML
005      
20121024153217.0
007      
ta
008      
120912s2012 xr fod f 000 0cze||
009      
AR
024    7_
$2 doi $a 10.55095/achot2012/045
040    __
$a ABA008 $d ABA008 $e AACR2 $b cze
041    0_
$a cze $b eng
044    __
$a xr
100    1_
$a Špička, Jan $7 xx0096849 $u Ortopedická klinika, LF UP a FN, Olomouc
245    10
$a TEP kyčle Plasmacup-Bicontact: výsledky s minimálně 10letým sledováním / $c J. Špička, L. Radová, J. Gallo
246    31
$a Cementless Plasmacup-Bicontact total hip arthroplasty. Results of a minimum of ten-year follow-up
500    __
$a Obsahuje 5 tabulek
504    __
$a Literatura $b 29
520    9_
$a PURPOSE OF THE STUDY The aim of the study was to analyse the long-term clinical and radiographic results of total hip arthroplasty (THA) with the Bicontact-Plasmacup prosthesis. MATERIAL AND METHODS In this retrospective observational study, 34 consecutive patients undergoing Bicontact-Plasmacup THA between August 1998 and July 2000 were evaluated. The group included 15 women and 19 men with an average age of 56 years (30 to 67 years). The mean ? SD of follow-up was 132 ? 9 months (122 to 149 months). Patients' satisfaction with the treatment outcome and selected clinical and radiographic features were evaluated. The data were analysed using the concordance test, Spearman's correlation coefficient and chi-square test. RESULTS At the final follow-up, 94% of the interviewed patients reported satisfaction with the surgery outcome. The mean Harris score was 93 (67 to 98) points, with excellent or very good results in 91% of the patients. Compared with the post-operative radiographs, the mean ? SD value for vertical migration of the acetabular cup was 2.43 ? 3.21 mm (0 to 12 mm) and that for horizontal migration was 0.35 ? 1.0 mm (0 to 4.3 mm). The mean stem subsidence was by 3.87 mm (range, 0.36 to 21.11 mm; SD 4.03). At the final follow-up, all implants showed radiographic stability and absence of radiolucent lines. Early acetabular osteolysis was detected in two patients (5.9 %). In 19 patients (56%) a change in bone architecture, similar to alterations due to weight-bearing adaptation, was seen around the cup following surgery. The stress shielding effect of the femoral component was recorded in 79%, bypass phenomenon in 41 % and pedestal formation under the apex of the stem in 18% of the patients. The mean rate of polyethylene wear measured by the Dorr and Wan method was 0.106 mm per year (range, 0.00 to 0.267 mm) or it was 0.078 mm per year (0.00 to 0.19 mm) when assessed by a modification of the method described by Kang et al. DISCUSSION The clinical and radiographic findings presented here are in accordance with the relevant literature data. This implant design is associated with a relatively infrequent osteolysis around the cup probably due to a low wear rate of polyethylene and a stable polyethylene liner-metal cup interface. Based on this work and some other studies it can be concluded that a post-operative migration of several millimetres is compatible with a long-term, stable cementless THA. CONCLUSIONS The Bicontact-Plasmacup THA meets the National Institute for Health and Clinical Excellence (NICE) criteria for a very good implant (ten-year survival rate of over 90%). At 10 years after surgery, however, the first signs of complaints about surgery outcome // dissatisfaction with surgery outcomes were recorded. This may, at least partly, be related to aseptic loosening which is one of the symptoms of particle disease.
650    _2
$a retrospektivní studie $7 D012189
650    _2
$a následné studie $7 D005500
650    _2
$a financování organizované $7 D005381
650    _2
$a náhrada kyčelního kloubu $7 D019644
650    _2
$a kyčelní protézy $x statistika a číselné údaje $x využití $7 D006622
650    _2
$a průzkumy a dotazníky $7 D011795
650    _2
$a mužské pohlaví $7 D008297
650    _2
$a ženské pohlaví $7 D005260
650    _2
$a lidé $7 D006801
650    _2
$a dospělí $7 D000328
650    _2
$a lidé středního věku $7 D008875
650    _2
$a senioři $7 D000368
650    _2
$a radiografie $7 D011859
650    _2
$a výsledek terapie $7 D016896
650    _2
$a spokojenost pacientů $7 D017060
650    _2
$a výsledky a postupy - zhodnocení (zdravotní péče) $x klasifikace $x statistika a číselné údaje $7 D010043
650    _2
$a interpretace statistických dat $7 D003627
650    _2
$a protézy a implantáty $x klasifikace $x statistika a číselné údaje $x využití $7 D019736
653    00
$a Plasmacup-Bicontact
700    1_
$a Radová, Lenka $7 xx0092752 $u Laboratoř experimentální medicíny, Ústav molekulární a translační medicíny, LF UP a FN, Olomouc
700    1_
$a Gallo, Jiří $7 xx0019005 $u Ortopedická klinika, LF UP a FN, Olomouc
773    0_
$t Acta chirurgiae orthopaedicae et traumatologiae čechoslovaca $x 0001-5415 $g Roč. 79, č. 4 (2012), s. 317-323 $w MED00011021
910    __
$a ABA008 $b A 8 $c 507 $y 2
990    __
$a 20120912072544 $b ABA008
991    __
$a 20121024153418 $b ABA008
999    __
$a ok $b bmc $g 951839 $s 786978
BAS    __
$a 3
BMC    __
$a 2012 $b 79 $c 4 $d 317-323 $i 0001-5415 $m Acta chirurgiae orthopaedicae et traumatologiae Čechoslovaca $n Acta chir. orthop. traumatol. Čechoslovaca $x MED00011021
LZP    __
$c NLK183 $d 20121024 $a 2012-40/ipeh

Najít záznam

Citační ukazatele

Nahrávání dat ...

Možnosti archivace

Nahrávání dat ...