-
Something wrong with this record ?
Electrokinetic injection across supported liquid membranes: new sample pretreatment technique for online coupling to capillary electrophoresis. Direct analysis of perchlorate in biological samples
P. Kubáň, IK. Kiplagat, P. Boček,
Language English Country Germany
Document type Journal Article, Research Support, Non-U.S. Gov't
NLK
Medline Complete (EBSCOhost)
from 2012-10-01 to 1 year ago
Wiley Online Library (archiv)
from 1999-01-01 to 2012-12-31
- MeSH
- Electrophoresis, Capillary instrumentation methods MeSH
- Hexanols chemistry MeSH
- Humans MeSH
- Limit of Detection MeSH
- Linear Models MeSH
- Membranes, Artificial MeSH
- Milk chemistry MeSH
- Perchlorates analysis blood urine MeSH
- Reproducibility of Results MeSH
- Cattle MeSH
- Wine analysis MeSH
- Environmental Exposure MeSH
- Animals MeSH
- Check Tag
- Humans MeSH
- Cattle MeSH
- Animals MeSH
- Publication type
- Journal Article MeSH
- Research Support, Non-U.S. Gov't MeSH
A simple and sensitive method for quantifying perchlorate in biological samples using CE and capacitively coupled contactless conductivity detection was developed. An online combination of a supported liquid membrane, an inert polypropylene membrane impregnated with 1-hexanol, and electrokinetic injection of perchlorate across the supported liquid membrane directly into the separation capillary reduced the need for laborious sample pretreatment procedures, resulting in a cheap and rapid method with low LODs capability. Baseline separation of perchlorate and other anions in biological samples was achieved in background electrolyte solution consisting of 15 mM nicotinic acid and 1 mM 3-(N,N-dimethylmyristylammonio)propanesulfonate at pH 3.3. The analytical method showed excellent parameters in terms of reproducibility; RSD values for peak areas and corrected migration times at a spiked concentration of 100 μg/L of perchlorate were below 10 and 0.4%, respectively. Linear calibration curves were obtained for perchlorate in the concentration range 10-1000 μg/L (r(2) >0.999) with LODs between 2 and 5 μg/L for human urine, breast milk, serum, cow's milk, and red wine. Recoveries at 25 μg/L of perchlorate were between 97 and 106% for all biological samples. The low LODs rivaling those of presently used analytical methods support the use of this method for quantification of perchlorate in biological samples in the future.
References provided by Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc13000590
- 003
- CZ-PrNML
- 005
- 20130109115514.0
- 007
- ta
- 008
- 130108s2012 gw f 000 0|eng||
- 009
- AR
- 024 7_
- $a 10.1002/elps.201200100 $2 doi
- 035 __
- $a (PubMed)22965714
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a gw
- 100 1_
- $a Kubáň, Pavel $u Institute of Analytical Chemistry of the Academy of Sciences of the Czech Republic, Brno, Czech Republic. kuban@iach.cz
- 245 10
- $a Electrokinetic injection across supported liquid membranes: new sample pretreatment technique for online coupling to capillary electrophoresis. Direct analysis of perchlorate in biological samples / $c P. Kubáň, IK. Kiplagat, P. Boček,
- 520 9_
- $a A simple and sensitive method for quantifying perchlorate in biological samples using CE and capacitively coupled contactless conductivity detection was developed. An online combination of a supported liquid membrane, an inert polypropylene membrane impregnated with 1-hexanol, and electrokinetic injection of perchlorate across the supported liquid membrane directly into the separation capillary reduced the need for laborious sample pretreatment procedures, resulting in a cheap and rapid method with low LODs capability. Baseline separation of perchlorate and other anions in biological samples was achieved in background electrolyte solution consisting of 15 mM nicotinic acid and 1 mM 3-(N,N-dimethylmyristylammonio)propanesulfonate at pH 3.3. The analytical method showed excellent parameters in terms of reproducibility; RSD values for peak areas and corrected migration times at a spiked concentration of 100 μg/L of perchlorate were below 10 and 0.4%, respectively. Linear calibration curves were obtained for perchlorate in the concentration range 10-1000 μg/L (r(2) >0.999) with LODs between 2 and 5 μg/L for human urine, breast milk, serum, cow's milk, and red wine. Recoveries at 25 μg/L of perchlorate were between 97 and 106% for all biological samples. The low LODs rivaling those of presently used analytical methods support the use of this method for quantification of perchlorate in biological samples in the future.
- 650 _2
- $a zvířata $7 D000818
- 650 _2
- $a skot $7 D002417
- 650 _2
- $a elektroforéza kapilární $x přístrojové vybavení $x metody $7 D019075
- 650 _2
- $a vystavení vlivu životního prostředí $7 D004781
- 650 _2
- $a hexanoly $x chemie $7 D000441
- 650 _2
- $a lidé $7 D006801
- 650 _2
- $a limita detekce $7 D057230
- 650 _2
- $a lineární modely $7 D016014
- 650 _2
- $a membrány umělé $7 D008567
- 650 _2
- $a mléko $x chemie $7 D008892
- 650 _2
- $a perchloráty $x analýza $x krev $x moč $7 D010472
- 650 _2
- $a reprodukovatelnost výsledků $7 D015203
- 650 _2
- $a víno $x analýza $7 D014920
- 655 _2
- $a časopisecké články $7 D016428
- 655 _2
- $a práce podpořená grantem $7 D013485
- 700 1_
- $a Kiplagat, Isaac K
- 700 1_
- $a Boček, Petr
- 773 0_
- $w MED00001508 $t Electrophoresis $x 1522-2683 $g Roč. 33, č. 17 (2012), s. 2695-702
- 856 41
- $u https://pubmed.ncbi.nlm.nih.gov/22965714 $y Pubmed
- 910 __
- $a ABA008 $b sig $c sign $y a $z 0
- 990 __
- $a 20130108 $b ABA008
- 991 __
- $a 20130109115619 $b ABA008
- 999 __
- $a ok $b bmc $g 963372 $s 798754
- BAS __
- $a 3
- BAS __
- $a PreBMC
- BMC __
- $a 2012 $b 33 $c 17 $d 2695-702 $i 1522-2683 $m Electrophoresis $n Electrophoresis $x MED00001508
- LZP __
- $a Pubmed-20130108