Detail
Článek
Článek online
FT
Medvik - BMČ
  • Je něco špatně v tomto záznamu ?

EuroFlow standardization of flow cytometer instrument settings and immunophenotyping protocols

T. Kalina, J. Flores-Montero, VH. van der Velden, M. Martin-Ayuso, S. Böttcher, M. Ritgen, J. Almeida, L. Lhermitte, V. Asnafi, A. Mendonça, R. de Tute, M. Cullen, L. Sedek, MB. Vidriales, JJ. Pérez, JG. te Marvelde, E. Mejstrikova, O. Hrusak, T....

. 2012 ; 26 (9) : 1986-2010.

Jazyk angličtina Země Anglie, Velká Británie

Typ dokumentu časopisecké články, práce podpořená grantem, přehledy

Perzistentní odkaz   https://www.medvik.cz/link/bmc13000593

Grantová podpora
NT12425 MZ0 CEP - Centrální evidence projektů

Digitální knihovna NLK
Plný text - Článek
Zdroj

E-zdroje Online Plný text

NLK ProQuest Central od 2000-01-01 do Před 1 rokem
Open Access Digital Library od 1997-01-01
Medline Complete (EBSCOhost) od 1997-01-01 do 2015-11-30
Nursing & Allied Health Database (ProQuest) od 2000-01-01 do Před 1 rokem
Health & Medicine (ProQuest) od 2000-01-01 do Před 1 rokem
Public Health Database (ProQuest) od 2000-01-01 do Před 1 rokem

The EU-supported EuroFlow Consortium aimed at innovation and standardization of immunophenotyping for diagnosis and classification of hematological malignancies by introducing 8-color flow cytometry with fully standardized laboratory procedures and antibody panels in order to achieve maximally comparable results among different laboratories. This required the selection of optimal combinations of compatible fluorochromes and the design and evaluation of adequate standard operating procedures (SOPs) for instrument setup, fluorescence compensation and sample preparation. Additionally, we developed software tools for the evaluation of individual antibody reagents and antibody panels. Each section describes what has been evaluated experimentally versus adopted based on existing data and experience. Multicentric evaluation demonstrated high levels of reproducibility based on strict implementation of the EuroFlow SOPs and antibody panels. Overall, the 6 years of extensive collaborative experiments and the analysis of hundreds of cell samples of patients and healthy controls in the EuroFlow centers have provided for the first time laboratory protocols and software tools for fully standardized 8-color flow cytometric immunophenotyping of normal and malignant leukocytes in bone marrow and blood; this has yielded highly comparable data sets, which can be integrated in a single database.

Citace poskytuje Crossref.org

000      
00000naa a2200000 a 4500
001      
bmc13000593
003      
CZ-PrNML
005      
20250108115617.0
007      
ta
008      
130108s2012 enk f 000 0|eng||
009      
AR
024    7_
$a 10.1038/leu.2012.122 $2 doi
035    __
$a (PubMed)22948490
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a enk
100    1_
$a Kalina, Tomáš, $u Department of Pediatric Hematology and Oncology, 2nd Faculty of Medicine, Charles University (DPH/O), Prague, Czech Republic. $d 1975 říjen 11.- $7 xx0060125
245    10
$a EuroFlow standardization of flow cytometer instrument settings and immunophenotyping protocols / $c T. Kalina, J. Flores-Montero, VH. van der Velden, M. Martin-Ayuso, S. Böttcher, M. Ritgen, J. Almeida, L. Lhermitte, V. Asnafi, A. Mendonça, R. de Tute, M. Cullen, L. Sedek, MB. Vidriales, JJ. Pérez, JG. te Marvelde, E. Mejstrikova, O. Hrusak, T. Szczepański, JJ. van Dongen, A. Orfao, . ,
520    9_
$a The EU-supported EuroFlow Consortium aimed at innovation and standardization of immunophenotyping for diagnosis and classification of hematological malignancies by introducing 8-color flow cytometry with fully standardized laboratory procedures and antibody panels in order to achieve maximally comparable results among different laboratories. This required the selection of optimal combinations of compatible fluorochromes and the design and evaluation of adequate standard operating procedures (SOPs) for instrument setup, fluorescence compensation and sample preparation. Additionally, we developed software tools for the evaluation of individual antibody reagents and antibody panels. Each section describes what has been evaluated experimentally versus adopted based on existing data and experience. Multicentric evaluation demonstrated high levels of reproducibility based on strict implementation of the EuroFlow SOPs and antibody panels. Overall, the 6 years of extensive collaborative experiments and the analysis of hundreds of cell samples of patients and healthy controls in the EuroFlow centers have provided for the first time laboratory protocols and software tools for fully standardized 8-color flow cytometric immunophenotyping of normal and malignant leukocytes in bone marrow and blood; this has yielded highly comparable data sets, which can be integrated in a single database.
650    _2
$a monoklonální protilátky $x diagnostické užití $7 D000911
650    _2
$a průtoková cytometrie $x přístrojové vybavení $x metody $x normy $7 D005434
650    _2
$a hematologické nádory $x diagnóza $x imunologie $7 D019337
650    _2
$a lidé $7 D006801
650    _2
$a imunofenotypizace $x normy $7 D016130
650    _2
$a laboratoře $x normy $7 D007753
650    _2
$a prognóza $7 D011379
650    _2
$a nádorové biomarkery $x imunologie $7 D014408
651    _2
$a Evropa $7 D005060
655    _2
$a časopisecké články $7 D016428
655    _2
$a práce podpořená grantem $7 D013485
655    _2
$a přehledy $7 D016454
700    1_
$a Flores-Montero, J
700    1_
$a van der Velden, V H J
700    1_
$a Martin-Ayuso, M
700    1_
$a Böttcher, Sebastian, $d 1971- $7 xx0327357
700    1_
$a Ritgen, M
700    1_
$a Almeida, J $7 gn_A_00004623
700    1_
$a Lhermitte, L
700    1_
$a Asnafi, V $7 gn_A_00009462
700    1_
$a Mendonça, A
700    1_
$a de Tute, R
700    1_
$a Cullen, M
700    1_
$a Sedek, L
700    1_
$a Vidriales, M B
700    1_
$a Pérez, J J
700    1_
$a te Marvelde, J G
700    1_
$a Mejstříková, Ester, $d 1977- $7 xx0105223
700    1_
$a Hrušák, Ondřej, $d 1965- $7 xx0036691
700    1_
$a Szczepański, T
700    1_
$a van Dongen, J J M
700    1_
$a Orfao, A
700    1_
$a ,
773    0_
$w MED00003138 $t Leukemia $x 1476-5551 $g Roč. 26, č. 9 (2012), s. 1986-2010
856    41
$u https://pubmed.ncbi.nlm.nih.gov/22948490 $y Pubmed
910    __
$a ABA008 $b sig $c sign $y a $z 0
990    __
$a 20130108 $b ABA008
991    __
$a 20250108115612 $b ABA008
999    __
$a ok $b bmc $g 963375 $s 798757
BAS    __
$a 3
BAS    __
$a PreBMC
BMC    __
$a 2012 $b 26 $c 9 $d 1986-2010 $i 1476-5551 $m Leukemia $n Leukemia $x MED00003138
GRA    __
$a NT12425 $p MZ0
LZP    __
$a Pubmed-20130108

Najít záznam

Citační ukazatele

Nahrávání dat ...

Možnosti archivace

Nahrávání dat ...