A simple sample pretreatment device with supported liquid membrane for direct injection of untreated body fluids and in-line coupling to a commercial CE instrument

P. Pantůčková, P. Kubáň, P. Boček,

. 2013 ; 34 (2) : 289-96.

Language English Country Germany

Document type Journal Article, Research Support, Non-U.S. Gov't

A simple sample pretreatment device was developed employing extractions across supported liquid membranes (SLMs) and in-line coupling to a commercial CE instrument. The device consisted of two polypropylene conical units interspaced with a polypropylene planar SLM, which were impregnated with 1-ethyl-2-nitrobenzene. The two units and the SLM were pressed against each other, donor unit was filled with 40 μL of an untreated body fluid and acceptor unit with 40 μL of DI water. The device was then placed into conventional CE vial fitted with a soft spring, which was depressed during injection into CE capillary and ensured that the SLM was not ruptured. Position of separation capillary injection end and high-voltage electrode in the CE instrument was optimized in order to ensure efficient injection of pretreated body fluids. The device can be easily assembled/disassembled and SLMs can be replaced after each extraction thus minimizing sample carry-over, avoiding tedious SLM regeneration, and reducing total pretreatment time and costs. The pretreatment device was examined by direct injection of human urine and serum spiked with nortriptyline, haloperidol, and loperamide. The basic drugs were diffusionaly transported across the SLM within 10 min and were injected into the separation capillary directly from the SLM surface in the acceptor unit, whereas matrix components were retained by the SLM. The in-line SLM-CE method showed good repeatability of peak areas (3.8-11.0%) and migration times (below 1.4%), linear relationship (r(2) = 0.990-0.999), and low LODs (12-100 μg/L).

References provided by Crossref.org

000      
00000naa a2200000 a 4500
001      
bmc13024144
003      
CZ-PrNML
005      
20130703125347.0
007      
ta
008      
130703s2013 gw f 000 0|eng||
009      
AR
024    7_
$a 10.1002/elps.201200369 $2 doi
035    __
$a (PubMed)23161384
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a gw
100    1_
$a Pantůčková, Pavla $u Institute of Analytical Chemistry, Academy of Sciences of the Czech Republic, v. v. i., Brno, Czech Republic.
245    12
$a A simple sample pretreatment device with supported liquid membrane for direct injection of untreated body fluids and in-line coupling to a commercial CE instrument / $c P. Pantůčková, P. Kubáň, P. Boček,
520    9_
$a A simple sample pretreatment device was developed employing extractions across supported liquid membranes (SLMs) and in-line coupling to a commercial CE instrument. The device consisted of two polypropylene conical units interspaced with a polypropylene planar SLM, which were impregnated with 1-ethyl-2-nitrobenzene. The two units and the SLM were pressed against each other, donor unit was filled with 40 μL of an untreated body fluid and acceptor unit with 40 μL of DI water. The device was then placed into conventional CE vial fitted with a soft spring, which was depressed during injection into CE capillary and ensured that the SLM was not ruptured. Position of separation capillary injection end and high-voltage electrode in the CE instrument was optimized in order to ensure efficient injection of pretreated body fluids. The device can be easily assembled/disassembled and SLMs can be replaced after each extraction thus minimizing sample carry-over, avoiding tedious SLM regeneration, and reducing total pretreatment time and costs. The pretreatment device was examined by direct injection of human urine and serum spiked with nortriptyline, haloperidol, and loperamide. The basic drugs were diffusionaly transported across the SLM within 10 min and were injected into the separation capillary directly from the SLM surface in the acceptor unit, whereas matrix components were retained by the SLM. The in-line SLM-CE method showed good repeatability of peak areas (3.8-11.0%) and migration times (below 1.4%), linear relationship (r(2) = 0.990-0.999), and low LODs (12-100 μg/L).
650    _2
$a elektroforéza kapilární $x přístrojové vybavení $x metody $7 D019075
650    _2
$a design vybavení $7 D004867
650    _2
$a lidé $7 D006801
650    12
$a membrány umělé $7 D008567
650    _2
$a léčivé přípravky $x krev $x izolace a purifikace $x moč $7 D004364
650    _2
$a reprodukovatelnost výsledků $7 D015203
655    _2
$a časopisecké články $7 D016428
655    _2
$a práce podpořená grantem $7 D013485
700    1_
$a Kubáň, Pavel $u -
700    1_
$a Boček, Petr $u -
773    0_
$w MED00001508 $t Electrophoresis $x 1522-2683 $g Roč. 34, č. 2 (2013), s. 289-96
856    41
$u https://pubmed.ncbi.nlm.nih.gov/23161384 $y Pubmed
910    __
$a ABA008 $b sig $c sign $y a $z 0
990    __
$a 20130703 $b ABA008
991    __
$a 20130703125805 $b ABA008
999    __
$a ok $b bmc $g 987824 $s 822524
BAS    __
$a 3
BAS    __
$a PreBMC
BMC    __
$a 2013 $b 34 $c 2 $d 289-96 $i 1522-2683 $m Electrophoresis $n Electrophoresis $x MED00001508
LZP    __
$a Pubmed-20130703

Find record

Citation metrics

Loading data ...

Archiving options

Loading data ...