• Je něco špatně v tomto záznamu ?

Estimation of ion competition via correlated responsivity offset in linear ion trap mass spectrometry analysis: theory and practical use in the analysis of cyanobacterial hepatotoxin microcystin-LR in extracts of food additives

J. Urban, P. Hrouzek, D. Stys, H. Martens,

. 2013 ; 2013 (-) : 414631.

Jazyk angličtina Země Spojené státy americké

Typ dokumentu časopisecké články, práce podpořená grantem

Perzistentní odkaz   https://www.medvik.cz/link/bmc14040815

Responsivity is a conversion qualification of a measurement device given by the functional dependence between the input and output quantities. A concentration-response-dependent calibration curve represents the most simple experiment for the measurement of responsivity in mass spectrometry. The cyanobacterial hepatotoxin microcystin-LR content in complex biological matrices of food additives was chosen as a model example of a typical problem. The calibration curves for pure microcystin and its mixtures with extracts of green alga and fish meat were reconstructed from the series of measurement. A novel approach for the quantitative estimation of ion competition in ESI is proposed in this paper. We define the correlated responsivity offset in the intensity values using the approximation of minimal correlation given by the matrix to the target mass values of the analyte. The estimation of the matrix influence enables the approximation of the position of a priori unknown responsivity and was easily evaluated using a simple algorithm. The method itself is directly derived from the basic attributes of the theory of measurements. There is sufficient agreement between the theoretical and experimental values. However, some theoretical issues are discussed to avoid misinterpretations and excessive expectations.

Citace poskytuje Crossref.org

000      
00000naa a2200000 a 4500
001      
bmc14040815
003      
CZ-PrNML
005      
20140110101724.0
007      
ta
008      
140107s2013 xxu f 000 0|eng||
009      
AR
024    7_
$a 10.1155/2013/414631 $2 doi
035    __
$a (PubMed)23586036
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a xxu
100    1_
$a Urban, Jan
245    10
$a Estimation of ion competition via correlated responsivity offset in linear ion trap mass spectrometry analysis: theory and practical use in the analysis of cyanobacterial hepatotoxin microcystin-LR in extracts of food additives / $c J. Urban, P. Hrouzek, D. Stys, H. Martens,
520    9_
$a Responsivity is a conversion qualification of a measurement device given by the functional dependence between the input and output quantities. A concentration-response-dependent calibration curve represents the most simple experiment for the measurement of responsivity in mass spectrometry. The cyanobacterial hepatotoxin microcystin-LR content in complex biological matrices of food additives was chosen as a model example of a typical problem. The calibration curves for pure microcystin and its mixtures with extracts of green alga and fish meat were reconstructed from the series of measurement. A novel approach for the quantitative estimation of ion competition in ESI is proposed in this paper. We define the correlated responsivity offset in the intensity values using the approximation of minimal correlation given by the matrix to the target mass values of the analyte. The estimation of the matrix influence enables the approximation of the position of a priori unknown responsivity and was easily evaluated using a simple algorithm. The method itself is directly derived from the basic attributes of the theory of measurements. There is sufficient agreement between the theoretical and experimental values. However, some theoretical issues are discussed to avoid misinterpretations and excessive expectations.
650    _2
$a sinice $x izolace a purifikace $7 D000458
650    _2
$a potravinářské přísady $x analýza $7 D005503
650    _2
$a lidé $7 D006801
650    _2
$a ionty $x chemie $x izolace a purifikace $7 D007477
650    12
$a hmotnostní spektrometrie $7 D013058
650    _2
$a mikrocystiny $x izolace a purifikace $7 D052998
650    _2
$a cyklické peptidy $x analýza $7 D010456
650    _2
$a regresní analýza $7 D012044
655    _2
$a časopisecké články $7 D016428
655    _2
$a práce podpořená grantem $7 D013485
700    1_
$a Hrouzek, Pavel $u -
700    1_
$a Stys, Dalibor $u -
700    1_
$a Martens, Harald $u -
773    0_
$w MED00182164 $t BioMed research international $x 2314-6141 $g Roč. 2013, č. - (2013), s. 414631
856    41
$u https://pubmed.ncbi.nlm.nih.gov/23586036 $y Pubmed
910    __
$a ABA008 $b sig $c sign $y a $z 0
990    __
$a 20140107 $b ABA008
991    __
$a 20140110102426 $b ABA008
999    __
$a ok $b bmc $g 1005211 $s 839327
BAS    __
$a 3
BAS    __
$a PreBMC
BMC    __
$a 2013 $b 2013 $c - $d 414631 $i 2314-6141 $m BioMed research international $n Biomed Res Int $x MED00182164
LZP    __
$a Pubmed-20140107

Najít záznam

Citační ukazatele

Nahrávání dat ...

Možnosti archivace

Nahrávání dat ...