Je něco špatně v tomto záznamu ?
Dual-phase dual-energy CT in patients with lung cancer: assessment of the additional value of iodine quantification in lymph node therapy response
J. Baxa, A. Vondráková, T. Matoušková, O. Růžičková, B. Schmidt, T. Flohr, M. Sedlmair, J. Ferda,
Jazyk angličtina Země Německo
Typ dokumentu časopisecké články, práce podpořená grantem
NLK
ProQuest Central
od 1997-01-01 do 2017-12-31
CINAHL Plus with Full Text (EBSCOhost)
od 2008-01-01 do Před 1 rokem
Medline Complete (EBSCOhost)
od 2000-01-01 do Před 1 rokem
Nursing & Allied Health Database (ProQuest)
od 1997-01-01 do 2017-12-31
Health & Medicine (ProQuest)
od 1997-01-01 do 2017-12-31
- MeSH
- dospělí MeSH
- jod diagnostické užití farmakokinetika MeSH
- kontrastní látky diagnostické užití farmakokinetika MeSH
- lidé středního věku MeSH
- lidé MeSH
- lymfadenektomie MeSH
- lymfatické uzliny patologie chirurgie MeSH
- mediastinum MeSH
- multidetektorová počítačová tomografie metody MeSH
- nádory plic metabolismus patologie radiografie MeSH
- nemalobuněčný karcinom plic radiografie sekundární MeSH
- reprodukovatelnost výsledků MeSH
- retrospektivní studie MeSH
- senioři MeSH
- staging nádorů metody MeSH
- Check Tag
- dospělí MeSH
- lidé středního věku MeSH
- lidé MeSH
- mužské pohlaví MeSH
- senioři MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH
OBJECTIVES: To investigate the potential contribution of iodine uptake calculation from dual-phase dual-energy CT (DE-CT) for lymph node staging and therapy response monitoring in lung cancer patients. METHODS: Retrospective analysis of 27 patients with non-small cell lung carcinoma (NSCLC), who underwent dual-phase DE-CT before and after chemotherapy, was performed. Iodine uptake (mg/mL) and total iodine uptake (mg) were calculated using prototype software in the early (arterial) and late (venous) post-contrast circulatory phase in 110 mediastinal lymph nodes. The arterial enhancement fraction (AEF) was calculated and compared with lymph node size and response to chemotherapy. RESULTS: A significant difference of AEF was observed between enlarged (90.4%; 32.3-238.5%) and non-enlarged (72.7%; -37.5-237.5%) lymph nodes (p = 0.044) before treatment onset. A significantly different change of AEF in responding (decrease of 26.3%; p = 0.022) and non-responding (increase of 43.0%; p = 0.031) lymph nodes was demonstrated. A higher value of AEF before treatment was observed in lymph nodes with subsequent favourable response (88.6% vs. 77.7%; p = 0.122), but this difference did not reach statistical significance. CONCLUSIONS: The dual-phase DE-CT examination with quantification of ratio of early and late post-contrast iodine uptake is a feasible and promising method for the functional evaluation of mediastinal lymph nodes including therapy response assessment. KEY POINTS: • Dual-phase DE-CT is beneficial for mediastinal lymph node assessment in NSCLC. • Arterial to venous iodine uptake ratio was higher in enlarged lymph nodes. • Change of arterial enhancement fraction correlated to therapy response.
Citace poskytuje Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc15023353
- 003
- CZ-PrNML
- 005
- 20161125083716.0
- 007
- ta
- 008
- 150709s2014 gw f 000 0|eng||
- 009
- AR
- 024 7_
- $a 10.1007/s00330-014-3223-9 $2 doi
- 035 __
- $a (PubMed)24895031
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a gw
- 100 1_
- $a Baxa, Jan $u Department of Imaging Methods, Charles University Teaching Hospital Plzen, alej Svobody 80, 306 40, Plzen, Czech Republic, baxaj@fnplzen.cz.
- 245 10
- $a Dual-phase dual-energy CT in patients with lung cancer: assessment of the additional value of iodine quantification in lymph node therapy response / $c J. Baxa, A. Vondráková, T. Matoušková, O. Růžičková, B. Schmidt, T. Flohr, M. Sedlmair, J. Ferda,
- 520 9_
- $a OBJECTIVES: To investigate the potential contribution of iodine uptake calculation from dual-phase dual-energy CT (DE-CT) for lymph node staging and therapy response monitoring in lung cancer patients. METHODS: Retrospective analysis of 27 patients with non-small cell lung carcinoma (NSCLC), who underwent dual-phase DE-CT before and after chemotherapy, was performed. Iodine uptake (mg/mL) and total iodine uptake (mg) were calculated using prototype software in the early (arterial) and late (venous) post-contrast circulatory phase in 110 mediastinal lymph nodes. The arterial enhancement fraction (AEF) was calculated and compared with lymph node size and response to chemotherapy. RESULTS: A significant difference of AEF was observed between enlarged (90.4%; 32.3-238.5%) and non-enlarged (72.7%; -37.5-237.5%) lymph nodes (p = 0.044) before treatment onset. A significantly different change of AEF in responding (decrease of 26.3%; p = 0.022) and non-responding (increase of 43.0%; p = 0.031) lymph nodes was demonstrated. A higher value of AEF before treatment was observed in lymph nodes with subsequent favourable response (88.6% vs. 77.7%; p = 0.122), but this difference did not reach statistical significance. CONCLUSIONS: The dual-phase DE-CT examination with quantification of ratio of early and late post-contrast iodine uptake is a feasible and promising method for the functional evaluation of mediastinal lymph nodes including therapy response assessment. KEY POINTS: • Dual-phase DE-CT is beneficial for mediastinal lymph node assessment in NSCLC. • Arterial to venous iodine uptake ratio was higher in enlarged lymph nodes. • Change of arterial enhancement fraction correlated to therapy response.
- 650 _2
- $a dospělí $7 D000328
- 650 _2
- $a senioři $7 D000368
- 650 _2
- $a nemalobuněčný karcinom plic $x radiografie $x sekundární $7 D002289
- 650 _2
- $a kontrastní látky $x diagnostické užití $x farmakokinetika $7 D003287
- 650 _2
- $a ženské pohlaví $7 D005260
- 650 _2
- $a lidé $7 D006801
- 650 _2
- $a jod $x diagnostické užití $x farmakokinetika $7 D007455
- 650 _2
- $a nádory plic $x metabolismus $x patologie $x radiografie $7 D008175
- 650 _2
- $a lymfadenektomie $7 D008197
- 650 _2
- $a lymfatické uzliny $x patologie $x radioizotopová diagnostika $x chirurgie $7 D008198
- 650 _2
- $a mužské pohlaví $7 D008297
- 650 _2
- $a mediastinum $7 D008482
- 650 _2
- $a lidé středního věku $7 D008875
- 650 _2
- $a multidetektorová počítačová tomografie $x metody $7 D061330
- 650 _2
- $a staging nádorů $x metody $7 D009367
- 650 _2
- $a reprodukovatelnost výsledků $7 D015203
- 650 _2
- $a retrospektivní studie $7 D012189
- 655 _2
- $a časopisecké články $7 D016428
- 655 _2
- $a práce podpořená grantem $7 D013485
- 700 1_
- $a Vondráková, Alena
- 700 1_
- $a Matoušková, Táňa $7 jo2012712038
- 700 1_
- $a Růžičková, Olga
- 700 1_
- $a Schmidt, Bernhard
- 700 1_
- $a Flohr, Thomas
- 700 1_
- $a Sedlmair, Martin
- 700 1_
- $a Ferda, Jiří
- 773 0_
- $w MED00009646 $t European radiology $x 1432-1084 $g Roč. 24, č. 8 (2014), s. 1981-8
- 856 41
- $u https://pubmed.ncbi.nlm.nih.gov/24895031 $y Pubmed
- 910 __
- $a ABA008 $b sig $c sign $y a $z 0
- 990 __
- $a 20150709 $b ABA008
- 991 __
- $a 20161125083712 $b ABA008
- 999 __
- $a ok $b bmc $g 1083691 $s 906346
- BAS __
- $a 3
- BAS __
- $a PreBMC
- BMC __
- $a 2014 $b 24 $c 8 $d 1981-8 $i 1432-1084 $m European radiology $n Eur Radiol $x MED00009646
- LZP __
- $a Pubmed-20150709