Detail
Článek
Článek online
FT
Medvik - BMČ
  • Je něco špatně v tomto záznamu ?

Dual-phase dual-energy CT in patients with lung cancer: assessment of the additional value of iodine quantification in lymph node therapy response

J. Baxa, A. Vondráková, T. Matoušková, O. Růžičková, B. Schmidt, T. Flohr, M. Sedlmair, J. Ferda,

. 2014 ; 24 (8) : 1981-8.

Jazyk angličtina Země Německo

Typ dokumentu časopisecké články, práce podpořená grantem

Perzistentní odkaz   https://www.medvik.cz/link/bmc15023353
E-zdroje Online Plný text

NLK ProQuest Central od 1997-01-01 do 2017-12-31
CINAHL Plus with Full Text (EBSCOhost) od 2008-01-01 do Před 1 rokem
Medline Complete (EBSCOhost) od 2000-01-01 do Před 1 rokem
Nursing & Allied Health Database (ProQuest) od 1997-01-01 do 2017-12-31
Health & Medicine (ProQuest) od 1997-01-01 do 2017-12-31

OBJECTIVES: To investigate the potential contribution of iodine uptake calculation from dual-phase dual-energy CT (DE-CT) for lymph node staging and therapy response monitoring in lung cancer patients. METHODS: Retrospective analysis of 27 patients with non-small cell lung carcinoma (NSCLC), who underwent dual-phase DE-CT before and after chemotherapy, was performed. Iodine uptake (mg/mL) and total iodine uptake (mg) were calculated using prototype software in the early (arterial) and late (venous) post-contrast circulatory phase in 110 mediastinal lymph nodes. The arterial enhancement fraction (AEF) was calculated and compared with lymph node size and response to chemotherapy. RESULTS: A significant difference of AEF was observed between enlarged (90.4%; 32.3-238.5%) and non-enlarged (72.7%; -37.5-237.5%) lymph nodes (p = 0.044) before treatment onset. A significantly different change of AEF in responding (decrease of 26.3%; p = 0.022) and non-responding (increase of 43.0%; p = 0.031) lymph nodes was demonstrated. A higher value of AEF before treatment was observed in lymph nodes with subsequent favourable response (88.6% vs. 77.7%; p = 0.122), but this difference did not reach statistical significance. CONCLUSIONS: The dual-phase DE-CT examination with quantification of ratio of early and late post-contrast iodine uptake is a feasible and promising method for the functional evaluation of mediastinal lymph nodes including therapy response assessment. KEY POINTS: • Dual-phase DE-CT is beneficial for mediastinal lymph node assessment in NSCLC. • Arterial to venous iodine uptake ratio was higher in enlarged lymph nodes. • Change of arterial enhancement fraction correlated to therapy response.

Citace poskytuje Crossref.org

000      
00000naa a2200000 a 4500
001      
bmc15023353
003      
CZ-PrNML
005      
20161125083716.0
007      
ta
008      
150709s2014 gw f 000 0|eng||
009      
AR
024    7_
$a 10.1007/s00330-014-3223-9 $2 doi
035    __
$a (PubMed)24895031
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a gw
100    1_
$a Baxa, Jan $u Department of Imaging Methods, Charles University Teaching Hospital Plzen, alej Svobody 80, 306 40, Plzen, Czech Republic, baxaj@fnplzen.cz.
245    10
$a Dual-phase dual-energy CT in patients with lung cancer: assessment of the additional value of iodine quantification in lymph node therapy response / $c J. Baxa, A. Vondráková, T. Matoušková, O. Růžičková, B. Schmidt, T. Flohr, M. Sedlmair, J. Ferda,
520    9_
$a OBJECTIVES: To investigate the potential contribution of iodine uptake calculation from dual-phase dual-energy CT (DE-CT) for lymph node staging and therapy response monitoring in lung cancer patients. METHODS: Retrospective analysis of 27 patients with non-small cell lung carcinoma (NSCLC), who underwent dual-phase DE-CT before and after chemotherapy, was performed. Iodine uptake (mg/mL) and total iodine uptake (mg) were calculated using prototype software in the early (arterial) and late (venous) post-contrast circulatory phase in 110 mediastinal lymph nodes. The arterial enhancement fraction (AEF) was calculated and compared with lymph node size and response to chemotherapy. RESULTS: A significant difference of AEF was observed between enlarged (90.4%; 32.3-238.5%) and non-enlarged (72.7%; -37.5-237.5%) lymph nodes (p = 0.044) before treatment onset. A significantly different change of AEF in responding (decrease of 26.3%; p = 0.022) and non-responding (increase of 43.0%; p = 0.031) lymph nodes was demonstrated. A higher value of AEF before treatment was observed in lymph nodes with subsequent favourable response (88.6% vs. 77.7%; p = 0.122), but this difference did not reach statistical significance. CONCLUSIONS: The dual-phase DE-CT examination with quantification of ratio of early and late post-contrast iodine uptake is a feasible and promising method for the functional evaluation of mediastinal lymph nodes including therapy response assessment. KEY POINTS: • Dual-phase DE-CT is beneficial for mediastinal lymph node assessment in NSCLC. • Arterial to venous iodine uptake ratio was higher in enlarged lymph nodes. • Change of arterial enhancement fraction correlated to therapy response.
650    _2
$a dospělí $7 D000328
650    _2
$a senioři $7 D000368
650    _2
$a nemalobuněčný karcinom plic $x radiografie $x sekundární $7 D002289
650    _2
$a kontrastní látky $x diagnostické užití $x farmakokinetika $7 D003287
650    _2
$a ženské pohlaví $7 D005260
650    _2
$a lidé $7 D006801
650    _2
$a jod $x diagnostické užití $x farmakokinetika $7 D007455
650    _2
$a nádory plic $x metabolismus $x patologie $x radiografie $7 D008175
650    _2
$a lymfadenektomie $7 D008197
650    _2
$a lymfatické uzliny $x patologie $x radioizotopová diagnostika $x chirurgie $7 D008198
650    _2
$a mužské pohlaví $7 D008297
650    _2
$a mediastinum $7 D008482
650    _2
$a lidé středního věku $7 D008875
650    _2
$a multidetektorová počítačová tomografie $x metody $7 D061330
650    _2
$a staging nádorů $x metody $7 D009367
650    _2
$a reprodukovatelnost výsledků $7 D015203
650    _2
$a retrospektivní studie $7 D012189
655    _2
$a časopisecké články $7 D016428
655    _2
$a práce podpořená grantem $7 D013485
700    1_
$a Vondráková, Alena
700    1_
$a Matoušková, Táňa $7 jo2012712038
700    1_
$a Růžičková, Olga
700    1_
$a Schmidt, Bernhard
700    1_
$a Flohr, Thomas
700    1_
$a Sedlmair, Martin
700    1_
$a Ferda, Jiří
773    0_
$w MED00009646 $t European radiology $x 1432-1084 $g Roč. 24, č. 8 (2014), s. 1981-8
856    41
$u https://pubmed.ncbi.nlm.nih.gov/24895031 $y Pubmed
910    __
$a ABA008 $b sig $c sign $y a $z 0
990    __
$a 20150709 $b ABA008
991    __
$a 20161125083712 $b ABA008
999    __
$a ok $b bmc $g 1083691 $s 906346
BAS    __
$a 3
BAS    __
$a PreBMC
BMC    __
$a 2014 $b 24 $c 8 $d 1981-8 $i 1432-1084 $m European radiology $n Eur Radiol $x MED00009646
LZP    __
$a Pubmed-20150709

Najít záznam

Citační ukazatele

Nahrávání dat ...

Možnosti archivace

Nahrávání dat ...