The risk of neurovascular injury in minimally invasive plate osteosynthesis (MIPO) when using a distal tibia anterolateral plate: a cadaver study [Riziko poranění neurovaskulárních struktur při miniinvazívní dlahové osteosyntéze (MIPO) s použitím distálnítibiální anterolaterální dlahy. Studie na kadaverech]

S. Lidder, S. Masterson, C. Grechenig, H. Clement, A. Gänsslen, S. Grechenig

. 2014 ; 81 (5) : 313-316.

Jazyk angličtina Země Česko

Typ dokumentu časopisecké články

Perzistentní odkaz   https://www.medvik.cz/link/bmc15029582

Digitální knihovna NLK
Zdroj

E-zdroje Online Plný text

NLK Free Medical Journals od 2006

PURPOSE OF THE STUDY: Percutaneous plating of the distal tibia via a limited incision is an accepted technique of osteosynthesis for extra-articular and simple intra-articular distal tibia fractures. The aim of this study was to analyze structures that are at risk during this approach. MATERIAL AND METHODS: Thirteen unpaired adult lower limbs were used for this study. Thirteen, 15-hole LCP anterolateral distal tibial plates were percutaneously inserted according to the recommended technique. Dissection was performed to examine the relation of the superficial and deep peroneal nerves and anterior tibial artery relative to the plate. RESULTS: The superficial peroneal nerve was found to cross the vertical limb of the LCP plate at a mean distance of 63 mm (screw hole five) but with a wide range of 21 to 105 mm. The neurovascular bundle (deep peroneal nerve and anterior tibial artery) crossed the plate at a mean of 76 mm (screw hole six) but also with a wide range of 38 to 138 mm. The zone of danger of the neurovascular structures ranges from 21 to 138 mm from the tibial plafond. In one specimen, a significant branch of the deep peroneal nerve was found to be entrapped under the plate. CONCLUSION: Caution is advised when using anterolateral minimally invasive technique for plate insertion and screw placement in the distal tibia due to great variability in the neurovascular structures that course distally in the lower leg and cross the ankle.

Riziko poranění neurovaskulárních struktur při miniinvazívní dlahové osteosyntéze (MIPO) s použitím distálnítibiální anterolaterální dlahy. Studie na kadaverech

Bibliografie atd.

Literatura

000      
00000naa a2200000 a 4500
001      
bmc15029582
003      
CZ-PrNML
005      
20150929133809.0
007      
ta
008      
150915s2014 xr ad f 000 0|eng||
009      
AR
024    7_
$2 doi $a 10.55095/achot2014/042
035    __
$a (PubMed)25514338
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a xr
100    1_
$a Lidder, S. $u Guy's and St Thomas' nHS Foundation Trust, Department of Trauma and Orthopaedics, London, UK
245    14
$a The risk of neurovascular injury in minimally invasive plate osteosynthesis (MIPO) when using a distal tibia anterolateral plate: a cadaver study / $c S. Lidder, S. Masterson, C. Grechenig, H. Clement, A. Gänsslen, S. Grechenig
246    31
$a Riziko poranění neurovaskulárních struktur při miniinvazívní dlahové osteosyntéze (MIPO) s použitím distálnítibiální anterolaterální dlahy. Studie na kadaverech
504    __
$a Literatura
520    3_
$a PURPOSE OF THE STUDY: Percutaneous plating of the distal tibia via a limited incision is an accepted technique of osteosynthesis for extra-articular and simple intra-articular distal tibia fractures. The aim of this study was to analyze structures that are at risk during this approach. MATERIAL AND METHODS: Thirteen unpaired adult lower limbs were used for this study. Thirteen, 15-hole LCP anterolateral distal tibial plates were percutaneously inserted according to the recommended technique. Dissection was performed to examine the relation of the superficial and deep peroneal nerves and anterior tibial artery relative to the plate. RESULTS: The superficial peroneal nerve was found to cross the vertical limb of the LCP plate at a mean distance of 63 mm (screw hole five) but with a wide range of 21 to 105 mm. The neurovascular bundle (deep peroneal nerve and anterior tibial artery) crossed the plate at a mean of 76 mm (screw hole six) but also with a wide range of 38 to 138 mm. The zone of danger of the neurovascular structures ranges from 21 to 138 mm from the tibial plafond. In one specimen, a significant branch of the deep peroneal nerve was found to be entrapped under the plate. CONCLUSION: Caution is advised when using anterolateral minimally invasive technique for plate insertion and screw placement in the distal tibia due to great variability in the neurovascular structures that course distally in the lower leg and cross the ankle.
650    _2
$a senioři $7 D000368
650    _2
$a senioři nad 80 let $7 D000369
650    12
$a kostní destičky $7 D001860
650    _2
$a mrtvola $7 D002102
650    _2
$a vnitřní fixace fraktury $x škodlivé účinky $x metody $7 D005593
650    _2
$a lidé $7 D006801
650    _2
$a lidé středního věku $7 D008875
650    _2
$a miniinvazivní chirurgické výkony $x škodlivé účinky $x metody $7 D019060
650    _2
$a nervus peroneus $x anatomie a histologie $x zranění $7 D010543
650    _2
$a rizikové faktory $7 D012307
650    _2
$a tibie $x anatomie a histologie $x chirurgie $7 D013977
650    _2
$a arteriae tibiales $x anatomie a histologie $x zranění $7 D016909
650    _2
$a fraktury tibie $x chirurgie $7 D013978
655    _2
$a časopisecké články $7 D016428
700    1_
$a Masterson, S. $u Queens Hospital, Department of Trauma and Orthopaedics, Romford, UK
700    1_
$a Grechenig, C. $u Medical University of Graz, Graz, Austria
700    1_
$a Clement, H. $u AUVA Trauma Hospital Graz, Graz, Austria
700    1_
$a Gänsslen, A. $u Department of Trauma, Orthopaedics and Hand Surgery, Klinikům Wolfsburg, Wolfsburg, Germany
700    1_
$a Grechenig, S. $u University Hospital Regensburg, Department of Traumatology, Regensburg, Germany
773    0_
$w MED00011021 $t Acta chirurgiae orthopaedicae et traumatologiae Čechoslovaca $x 0001-5415 $g Roč. 81, č. 5 (2014), s. 313-316
910    __
$a ABA008 $b A 8 $c 507 $y 4 $z 0
990    __
$a 20150915 $b ABA008
991    __
$a 20150923103343 $b ABA008
999    __
$a ok $b bmc $g 1091506 $s 912670
BAS    __
$a 3
BAS    __
$a PreBMC
BMC    __
$a 2014 $b 81 $c 5 $d 313-316 $i 0001-5415 $m Acta chirurgiae orthopaedicae et traumatologiae Čechoslovaca $n Acta chir. orthop. traumatol. Čechoslovaca $x MED00011021
LZP    __
$b NLK118 $a Pubmed-20150915