Artificially low cortical bone mineral density in Turner syndrome is due to the partial volume effect
O. Soucek, E. Schönau, J. Lebl, Z. Sumnik,
Language English Country England, Great Britain
Document type Journal Article, Research Support, Non-U.S. Gov't
NLK
ProQuest Central
from 1997-01-01 to 1 year ago
Medline Complete (EBSCOhost)
from 2000-01-01 to 1 year ago
Nursing & Allied Health Database (ProQuest)
from 1997-01-01 to 1 year ago
Health & Medicine (ProQuest)
from 1997-01-01 to 1 year ago
Public Health Database (ProQuest)
from 1997-01-01 to 1 year ago
- MeSH
- Child MeSH
- Bone Density physiology MeSH
- Humans MeSH
- Adolescent MeSH
- Young Adult MeSH
- Tomography, X-Ray Computed methods MeSH
- Cross-Sectional Studies MeSH
- Radius radiography MeSH
- Case-Control Studies MeSH
- Tibia radiography MeSH
- Turner Syndrome radiography MeSH
- Check Tag
- Child MeSH
- Humans MeSH
- Adolescent MeSH
- Young Adult MeSH
- Male MeSH
- Female MeSH
- Publication type
- Journal Article MeSH
- Research Support, Non-U.S. Gov't MeSH
UNLABELLED: We aimed to show that the decrease in the cortical bone mineral density (BMD) in the radius in Turner syndrome (TS) is artificially caused by the partial volume effect. We confirmed that the partial volume effect-corrected cortical BMD is not decreased in TS compared to in the healthy controls. Other factors are responsible for the increased fracture rate in TS. INTRODUCTION: Decreased cortical bone mineral density (BMD) has been reported in Turner syndrome (TS), using peripheral quantitative computerised tomography, and it is perceived as one of the major factors leading to increased fracture risk. We tested the hypothesis that low cortical BMD in the radius is caused artificially by the partial volume effect. METHODS: A cross-sectional study was conducted at the university hospital referral centre between March and October 2013. Thirty-two participants with TS who consented to the study were included (mean age 15.3 ± 3.2 years). We assessed the cortical BMD in the radius as well as the tibia, where the cortex is thicker compared with the radius. RESULTS: Whereas the cortical BMD was decreased in the radius (mean ± SD Z-score -0.6 ± 1.5, p = 0.037), it was increased in the tibia (mean Z-score 0.83 ± 1.0, p < 0.001). After correcting the cortical BMD for the partial volume effect, the mean Z-score was normal in the radius in TS (0.4 ± 1.3, p = 0.064). The corrected cortical BMD values were similar in the radius and tibia (1108 ± 52 vs. 1104 ± 48, group difference p = 0.75). CONCLUSIONS: The cortical BMD is not decreased in TS. The partial volume effect is responsible for previous findings of decreased cortical BMD in the radius. Altered bone geometry or other factors rather than low cortical BMD likely play a role in the increased fracture risk in TS.
References provided by Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc16000601
- 003
- CZ-PrNML
- 005
- 20160127094355.0
- 007
- ta
- 008
- 160108s2015 enk f 000 0|eng||
- 009
- AR
- 024 7_
- $a 10.1007/s00198-014-2901-4 $2 doi
- 035 __
- $a (PubMed)25288443
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a enk
- 100 1_
- $a Soucek, O $u Department of Pediatrics, 2nd Faculty of Medicine, Charles University in Prague and Motol University Hospital, V Uvalu 84, 150 06, Praha 5, Czech Republic, ondrej.soucek@lfmotol.cuni.cz.
- 245 10
- $a Artificially low cortical bone mineral density in Turner syndrome is due to the partial volume effect / $c O. Soucek, E. Schönau, J. Lebl, Z. Sumnik,
- 520 9_
- $a UNLABELLED: We aimed to show that the decrease in the cortical bone mineral density (BMD) in the radius in Turner syndrome (TS) is artificially caused by the partial volume effect. We confirmed that the partial volume effect-corrected cortical BMD is not decreased in TS compared to in the healthy controls. Other factors are responsible for the increased fracture rate in TS. INTRODUCTION: Decreased cortical bone mineral density (BMD) has been reported in Turner syndrome (TS), using peripheral quantitative computerised tomography, and it is perceived as one of the major factors leading to increased fracture risk. We tested the hypothesis that low cortical BMD in the radius is caused artificially by the partial volume effect. METHODS: A cross-sectional study was conducted at the university hospital referral centre between March and October 2013. Thirty-two participants with TS who consented to the study were included (mean age 15.3 ± 3.2 years). We assessed the cortical BMD in the radius as well as the tibia, where the cortex is thicker compared with the radius. RESULTS: Whereas the cortical BMD was decreased in the radius (mean ± SD Z-score -0.6 ± 1.5, p = 0.037), it was increased in the tibia (mean Z-score 0.83 ± 1.0, p < 0.001). After correcting the cortical BMD for the partial volume effect, the mean Z-score was normal in the radius in TS (0.4 ± 1.3, p = 0.064). The corrected cortical BMD values were similar in the radius and tibia (1108 ± 52 vs. 1104 ± 48, group difference p = 0.75). CONCLUSIONS: The cortical BMD is not decreased in TS. The partial volume effect is responsible for previous findings of decreased cortical BMD in the radius. Altered bone geometry or other factors rather than low cortical BMD likely play a role in the increased fracture risk in TS.
- 650 _2
- $a mladiství $7 D000293
- 650 _2
- $a kostní denzita $x fyziologie $7 D015519
- 650 _2
- $a studie případů a kontrol $7 D016022
- 650 _2
- $a dítě $7 D002648
- 650 _2
- $a průřezové studie $7 D003430
- 650 _2
- $a ženské pohlaví $7 D005260
- 650 _2
- $a lidé $7 D006801
- 650 _2
- $a mužské pohlaví $7 D008297
- 650 _2
- $a radius $x radiografie $7 D011884
- 650 _2
- $a tibie $x radiografie $7 D013977
- 650 _2
- $a počítačová rentgenová tomografie $x metody $7 D014057
- 650 _2
- $a Turnerův syndrom $x radiografie $7 D014424
- 650 _2
- $a mladý dospělý $7 D055815
- 655 _2
- $a časopisecké články $7 D016428
- 655 _2
- $a práce podpořená grantem $7 D013485
- 700 1_
- $a Schönau, E
- 700 1_
- $a Lebl, J
- 700 1_
- $a Sumnik, Z
- 773 0_
- $w MED00003659 $t Osteoporosis international a journal established as result of cooperation between the European Foundation for Osteoporosis and the National Osteoporosis Foundation of the USA $x 1433-2965 $g Roč. 26, č. 3 (2015), s. 1213-8
- 856 41
- $u https://pubmed.ncbi.nlm.nih.gov/25288443 $y Pubmed
- 910 __
- $a ABA008 $b sig $c sign $y a $z 0
- 990 __
- $a 20160108 $b ABA008
- 991 __
- $a 20160127094520 $b ABA008
- 999 __
- $a ok $b bmc $g 1102882 $s 924807
- BAS __
- $a 3
- BAS __
- $a PreBMC
- BMC __
- $a 2015 $b 26 $c 3 $d 1213-8 $e 20141007 $i 1433-2965 $m Osteoporosis international $n Osteoporos Int $x MED00003659
- LZP __
- $a Pubmed-20160108