Je něco špatně v tomto záznamu ?
The effect of ICD programming on inappropriate and appropriate ICD Therapies in ischemic and nonischemic cardiomyopathy: the MADIT-RIT trial
K. Sedláček, AC. Ruwald, V. Kutyifa, S. McNitt, PE. Thomsen, H. Klein, M. Stockburger, D. Wichterle, B. Merkely, JF. DE LA Concha, M. Swissa, W. Zareba, AJ. Moss, J. Kautzner, MH. Ruwald, . ,
Jazyk angličtina Země Spojené státy americké
Typ dokumentu časopisecké články, multicentrická studie, randomizované kontrolované studie, práce podpořená grantem
NLK
CINAHL Plus with Full Text (EBSCOhost)
od 1990-02-01 do Před 1 rokem
Medline Complete (EBSCOhost)
od 1990-02-01 do Před 1 rokem
PubMed
25546486
DOI
10.1111/jce.12605
Knihovny.cz E-zdroje
- MeSH
- časové faktory MeSH
- defibrilátory implantabilní * MeSH
- design vybavení MeSH
- elektrická defibrilace škodlivé účinky přístrojové vybavení mortalita MeSH
- elektrofyziologické techniky kardiologické MeSH
- ischemická choroba srdeční komplikace diagnóza mortalita MeSH
- Kaplanův-Meierův odhad MeSH
- kardiomyopatie diagnóza etiologie mortalita patofyziologie MeSH
- komorová tachykardie diagnóza etiologie mortalita patofyziologie terapie MeSH
- lidé středního věku MeSH
- lidé MeSH
- multivariační analýza MeSH
- náhlá srdeční smrt etiologie prevence a kontrola MeSH
- počítačové zpracování signálu MeSH
- prediktivní hodnota testů MeSH
- proporcionální rizikové modely MeSH
- rizikové faktory MeSH
- rozdělení chí kvadrát MeSH
- selhání zařízení * MeSH
- senioři MeSH
- výsledek terapie MeSH
- Check Tag
- lidé středního věku MeSH
- lidé MeSH
- mužské pohlaví MeSH
- senioři MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- multicentrická studie MeSH
- práce podpořená grantem MeSH
- randomizované kontrolované studie MeSH
- Geografické názvy
- Evropa MeSH
- Izrael MeSH
- Spojené státy americké MeSH
INTRODUCTION: The MADIT-RIT trial demonstrated reduction of inappropriate and appropriate ICD therapies and mortality by high-rate cut-off and 60-second-delayed VT therapy ICD programming in patients with a primary prophylactic ICD indication. The aim of this analysis was to study effects of MADIT-RIT ICD programming in patients with ischemic and nonischemic cardiomyopathy. METHODS AND RESULTS: First and total occurrences of both inappropriate and appropriate ICD therapies were analyzed by multivariate Cox models in 791 (53%) patients with ischemic and 707 (47%) patients with nonischemic cardiomyopathy. Patients with ischemic and nonischemic cardiomyopathy had similar incidence of first inappropriate (9% and 11%, P = 0.21) and first appropriate ICD therapy (11.6% and 14.1%, P = 0.15). Patients with ischemic cardiomyopathy had higher mortality rate (6.1% vs. 3.3%, P = 0.01). MADIT-RIT high-rate cut-off (arm B) and delayed VT therapy ICD programming (arm C) compared with conventional (arm A) ICD programming were associated with a significant risk reduction of first inappropriate and appropriate ICD therapy in patients with ischemic and nonischemic cardiomyopathy (HR range 0.11-0.34, P < 0.001 for all comparisons). Occurrence of total inappropriate and appropriate ICD therapies was significantly reduced by high-rate cut-off ICD programming and delayed VT therapy ICD programming in both ischemic and nonischemic cardiomyopathy patients. CONCLUSION: High-rate cut-off and delayed VT therapy ICD programming are associated with significant reduction in first and total inappropriate and appropriate ICD therapy in patients with ischemic and nonischemic cardiomyopathy.
Citace poskytuje Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc16010648
- 003
- CZ-PrNML
- 005
- 20170502073507.0
- 007
- ta
- 008
- 160408s2015 xxu f 000 0|eng||
- 009
- AR
- 024 7_
- $a 10.1111/jce.12605 $2 doi
- 024 7_
- $a 10.1111/jce.12605 $2 doi
- 035 __
- $a (PubMed)25546486
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a xxu
- 100 1_
- $a Sedláček, Kamil $u Cardiology Department, Institute for Clinical and Experimental Medicine, Prague, Czech Republic.
- 245 14
- $a The effect of ICD programming on inappropriate and appropriate ICD Therapies in ischemic and nonischemic cardiomyopathy: the MADIT-RIT trial / $c K. Sedláček, AC. Ruwald, V. Kutyifa, S. McNitt, PE. Thomsen, H. Klein, M. Stockburger, D. Wichterle, B. Merkely, JF. DE LA Concha, M. Swissa, W. Zareba, AJ. Moss, J. Kautzner, MH. Ruwald, . ,
- 520 9_
- $a INTRODUCTION: The MADIT-RIT trial demonstrated reduction of inappropriate and appropriate ICD therapies and mortality by high-rate cut-off and 60-second-delayed VT therapy ICD programming in patients with a primary prophylactic ICD indication. The aim of this analysis was to study effects of MADIT-RIT ICD programming in patients with ischemic and nonischemic cardiomyopathy. METHODS AND RESULTS: First and total occurrences of both inappropriate and appropriate ICD therapies were analyzed by multivariate Cox models in 791 (53%) patients with ischemic and 707 (47%) patients with nonischemic cardiomyopathy. Patients with ischemic and nonischemic cardiomyopathy had similar incidence of first inappropriate (9% and 11%, P = 0.21) and first appropriate ICD therapy (11.6% and 14.1%, P = 0.15). Patients with ischemic cardiomyopathy had higher mortality rate (6.1% vs. 3.3%, P = 0.01). MADIT-RIT high-rate cut-off (arm B) and delayed VT therapy ICD programming (arm C) compared with conventional (arm A) ICD programming were associated with a significant risk reduction of first inappropriate and appropriate ICD therapy in patients with ischemic and nonischemic cardiomyopathy (HR range 0.11-0.34, P < 0.001 for all comparisons). Occurrence of total inappropriate and appropriate ICD therapies was significantly reduced by high-rate cut-off ICD programming and delayed VT therapy ICD programming in both ischemic and nonischemic cardiomyopathy patients. CONCLUSION: High-rate cut-off and delayed VT therapy ICD programming are associated with significant reduction in first and total inappropriate and appropriate ICD therapy in patients with ischemic and nonischemic cardiomyopathy.
- 650 _2
- $a senioři $7 D000368
- 650 _2
- $a kardiomyopatie $x diagnóza $x etiologie $x mortalita $x patofyziologie $7 D009202
- 650 _2
- $a rozdělení chí kvadrát $7 D016009
- 650 _2
- $a náhlá srdeční smrt $x etiologie $x prevence a kontrola $7 D016757
- 650 12
- $a defibrilátory implantabilní $7 D017147
- 650 _2
- $a elektrická defibrilace $x škodlivé účinky $x přístrojové vybavení $x mortalita $7 D004554
- 650 _2
- $a elektrofyziologické techniky kardiologické $7 D022062
- 650 _2
- $a design vybavení $7 D004867
- 650 12
- $a selhání zařízení $7 D004868
- 650 _2
- $a ženské pohlaví $7 D005260
- 650 _2
- $a lidé $7 D006801
- 650 _2
- $a Kaplanův-Meierův odhad $7 D053208
- 650 _2
- $a mužské pohlaví $7 D008297
- 650 _2
- $a lidé středního věku $7 D008875
- 650 _2
- $a multivariační analýza $7 D015999
- 650 _2
- $a ischemická choroba srdeční $x komplikace $x diagnóza $x mortalita $7 D017202
- 650 _2
- $a prediktivní hodnota testů $7 D011237
- 650 _2
- $a proporcionální rizikové modely $7 D016016
- 650 _2
- $a rizikové faktory $7 D012307
- 650 _2
- $a počítačové zpracování signálu $7 D012815
- 650 _2
- $a komorová tachykardie $x diagnóza $x etiologie $x mortalita $x patofyziologie $x terapie $7 D017180
- 650 _2
- $a časové faktory $7 D013997
- 650 _2
- $a výsledek terapie $7 D016896
- 651 _2
- $a Evropa $7 D005060
- 651 _2
- $a Izrael $7 D007557
- 651 _2
- $a Spojené státy americké $7 D014481
- 655 _2
- $a časopisecké články $7 D016428
- 655 _2
- $a multicentrická studie $7 D016448
- 655 _2
- $a randomizované kontrolované studie $7 D016449
- 655 _2
- $a práce podpořená grantem $7 D013485
- 700 1_
- $a Ruwald, Anne-Christine
- 700 1_
- $a Kutyifa, Valentina
- 700 1_
- $a McNitt, Scott
- 700 1_
- $a Thomsen, Poul Erik Bloch
- 700 1_
- $a Klein, Helmut
- 700 1_
- $a Stockburger, Martin
- 700 1_
- $a Wichterle, Dan
- 700 1_
- $a Merkely, Bela
- 700 1_
- $a DE LA Concha, Joaquin Fernandez
- 700 1_
- $a Swissa, Moshe
- 700 1_
- $a Zareba, Wojciech
- 700 1_
- $a Moss, Arthur J., $d 1914-2004 $7 uk2007404259
- 700 1_
- $a Kautzner, Josef
- 700 1_
- $a Ruwald, Martin H
- 700 1_
- $a ,
- 773 0_
- $w MED00002569 $t Journal of cardiovascular electrophysiology $x 1540-8167 $g Roč. 26, č. 4 (2015), s. 424-33
- 856 41
- $u https://pubmed.ncbi.nlm.nih.gov/25546486 $y Pubmed
- 910 __
- $a ABA008 $b sig $c sign $y a $z 0
- 990 __
- $a 20160408 $b ABA008
- 991 __
- $a 20170502073834 $b ABA008
- 999 __
- $a ok $b bmc $g 1114077 $s 935016
- BAS __
- $a 3
- BAS __
- $a PreBMC
- BMC __
- $a 2015 $b 26 $c 4 $d 424-33 $e 20150211 $i 1540-8167 $m Journal of cardiovascular electrophysiology $n J Cardiovasc Electrophysiol $x MED00002569
- LZP __
- $a Pubmed-20160408