-
Something wrong with this record ?
Registration of retinal sequences from new video-ophthalmoscopic camera
R. Kolar, RP. Tornow, J. Odstrcilik, I. Liberdova,
Language English Country England, Great Britain
Document type Journal Article
NLK
BioMedCentral
from 2002-12-01
BioMedCentral Open Access
from 2002
Directory of Open Access Journals
from 2002
Free Medical Journals
from 2002
Freely Accessible Science Journals
from 2002
PubMed Central
from 2002
Europe PubMed Central
from 2002
ProQuest Central
from 2009-01-01
Open Access Digital Library
from 2002-01-01
Open Access Digital Library
from 2002-01-01
Open Access Digital Library
from 2002-05-01
Medline Complete (EBSCOhost)
from 2002-05-14
Health & Medicine (ProQuest)
from 2009-01-01
ROAD: Directory of Open Access Scholarly Resources
from 2002
Springer Nature OA/Free Journals
from 2002-12-01
- MeSH
- Algorithms MeSH
- Humans MeSH
- Ophthalmoscopes * MeSH
- Image Processing, Computer-Assisted methods MeSH
- Eye Movements MeSH
- Signal-To-Noise Ratio MeSH
- Retina * physiology MeSH
- Retinal Vessels cytology MeSH
- Videotape Recording MeSH
- Check Tag
- Humans MeSH
- Publication type
- Journal Article MeSH
BACKGROUND: Analysis of fast temporal changes on retinas has become an important part of diagnostic video-ophthalmology. It enables investigation of the hemodynamic processes in retinal tissue, e.g. blood-vessel diameter changes as a result of blood-pressure variation, spontaneous venous pulsation influenced by intracranial-intraocular pressure difference, blood-volume changes as a result of changes in light reflection from retinal tissue, and blood flow using laser speckle contrast imaging. For such applications, image registration of the recorded sequence must be performed. METHODS: Here we use a new non-mydriatic video-ophthalmoscope for simple and fast acquisition of low SNR retinal sequences. We introduce a novel, two-step approach for fast image registration. The phase correlation in the first stage removes large eye movements. Lucas-Kanade tracking in the second stage removes small eye movements. We propose robust adaptive selection of the tracking points, which is the most important part of tracking-based approaches. We also describe a method for quantitative evaluation of the registration results, based on vascular tree intensity profiles. RESULTS: The achieved registration error evaluated on 23 sequences (5840 frames) is 0.78 ± 0.67 pixels inside the optic disc and 1.39 ± 0.63 pixels outside the optic disc. We compared the results with the commonly used approaches based on Lucas-Kanade tracking and scale-invariant feature transform, which achieved worse results. CONCLUSION: The proposed method can efficiently correct particular frames of retinal sequences for shift and rotation. The registration results for each frame (shift in X and Y direction and eye rotation) can also be used for eye-movement evaluation during single-spot fixation tasks.
References provided by Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc17013842
- 003
- CZ-PrNML
- 005
- 20170418105825.0
- 007
- ta
- 008
- 170413s2016 enk f 000 0|eng||
- 009
- AR
- 024 7_
- $a 10.1186/s12938-016-0191-0 $2 doi
- 035 __
- $a (PubMed)27206477
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a enk
- 100 1_
- $a Kolar, Radim $u Department of Biomedical Engineering, Faculty of Electrical Engineering and Communication, Brno University of Technology, Technicka 12, 616 00, Brno, Czech Republic. kolarr@feec.vutbr.cz.
- 245 10
- $a Registration of retinal sequences from new video-ophthalmoscopic camera / $c R. Kolar, RP. Tornow, J. Odstrcilik, I. Liberdova,
- 520 9_
- $a BACKGROUND: Analysis of fast temporal changes on retinas has become an important part of diagnostic video-ophthalmology. It enables investigation of the hemodynamic processes in retinal tissue, e.g. blood-vessel diameter changes as a result of blood-pressure variation, spontaneous venous pulsation influenced by intracranial-intraocular pressure difference, blood-volume changes as a result of changes in light reflection from retinal tissue, and blood flow using laser speckle contrast imaging. For such applications, image registration of the recorded sequence must be performed. METHODS: Here we use a new non-mydriatic video-ophthalmoscope for simple and fast acquisition of low SNR retinal sequences. We introduce a novel, two-step approach for fast image registration. The phase correlation in the first stage removes large eye movements. Lucas-Kanade tracking in the second stage removes small eye movements. We propose robust adaptive selection of the tracking points, which is the most important part of tracking-based approaches. We also describe a method for quantitative evaluation of the registration results, based on vascular tree intensity profiles. RESULTS: The achieved registration error evaluated on 23 sequences (5840 frames) is 0.78 ± 0.67 pixels inside the optic disc and 1.39 ± 0.63 pixels outside the optic disc. We compared the results with the commonly used approaches based on Lucas-Kanade tracking and scale-invariant feature transform, which achieved worse results. CONCLUSION: The proposed method can efficiently correct particular frames of retinal sequences for shift and rotation. The registration results for each frame (shift in X and Y direction and eye rotation) can also be used for eye-movement evaluation during single-spot fixation tasks.
- 650 _2
- $a algoritmy $7 D000465
- 650 _2
- $a pohyby očí $7 D005133
- 650 _2
- $a lidé $7 D006801
- 650 _2
- $a počítačové zpracování obrazu $x metody $7 D007091
- 650 12
- $a oftalmoskopy $7 D019721
- 650 12
- $a retina $x fyziologie $7 D012160
- 650 _2
- $a retinální cévy $x cytologie $7 D012171
- 650 _2
- $a poměr signál - šum $7 D059629
- 650 _2
- $a videozáznam $7 D014743
- 655 _2
- $a časopisecké články $7 D016428
- 700 1_
- $a Tornow, Ralf P $u Department of Ophthalmology, Friedrich-Alexander-University Erlangen-Nürnberg, Schwabachanlage 6, 91054, Erlangen, Germany.
- 700 1_
- $a Odstrcilik, Jan $u Department of Biomedical Engineering, Faculty of Electrical Engineering and Communication, Brno University of Technology, Technicka 12, 616 00, Brno, Czech Republic.
- 700 1_
- $a Liberdova, Ivana $u Department of Biomedical Engineering, Faculty of Electrical Engineering and Communication, Brno University of Technology, Technicka 12, 616 00, Brno, Czech Republic.
- 773 0_
- $w MED00008166 $t Biomedical engineering online $x 1475-925X $g Roč. 15, č. 1 (2016), s. 57
- 856 41
- $u https://pubmed.ncbi.nlm.nih.gov/27206477 $y Pubmed
- 910 __
- $a ABA008 $b sig $c sign $y a $z 0
- 990 __
- $a 20170413 $b ABA008
- 991 __
- $a 20170418110133 $b ABA008
- 999 __
- $a ok $b bmc $g 1200307 $s 974620
- BAS __
- $a 3
- BAS __
- $a PreBMC
- BMC __
- $a 2016 $b 15 $c 1 $d 57 $e 20160520 $i 1475-925X $m Biomedical engineering online $n Biomed Eng Online $x MED00008166
- LZP __
- $a Pubmed-20170413