Detail
Article
Online article
FT
Medvik - BMC
  • Something wrong with this record ?

Registration of retinal sequences from new video-ophthalmoscopic camera

R. Kolar, RP. Tornow, J. Odstrcilik, I. Liberdova,

. 2016 ; 15 (1) : 57. [pub] 20160520

Language English Country England, Great Britain

Document type Journal Article

BACKGROUND: Analysis of fast temporal changes on retinas has become an important part of diagnostic video-ophthalmology. It enables investigation of the hemodynamic processes in retinal tissue, e.g. blood-vessel diameter changes as a result of blood-pressure variation, spontaneous venous pulsation influenced by intracranial-intraocular pressure difference, blood-volume changes as a result of changes in light reflection from retinal tissue, and blood flow using laser speckle contrast imaging. For such applications, image registration of the recorded sequence must be performed. METHODS: Here we use a new non-mydriatic video-ophthalmoscope for simple and fast acquisition of low SNR retinal sequences. We introduce a novel, two-step approach for fast image registration. The phase correlation in the first stage removes large eye movements. Lucas-Kanade tracking in the second stage removes small eye movements. We propose robust adaptive selection of the tracking points, which is the most important part of tracking-based approaches. We also describe a method for quantitative evaluation of the registration results, based on vascular tree intensity profiles. RESULTS: The achieved registration error evaluated on 23 sequences (5840 frames) is 0.78 ± 0.67 pixels inside the optic disc and 1.39 ± 0.63 pixels outside the optic disc. We compared the results with the commonly used approaches based on Lucas-Kanade tracking and scale-invariant feature transform, which achieved worse results. CONCLUSION: The proposed method can efficiently correct particular frames of retinal sequences for shift and rotation. The registration results for each frame (shift in X and Y direction and eye rotation) can also be used for eye-movement evaluation during single-spot fixation tasks.

References provided by Crossref.org

000      
00000naa a2200000 a 4500
001      
bmc17013842
003      
CZ-PrNML
005      
20170418105825.0
007      
ta
008      
170413s2016 enk f 000 0|eng||
009      
AR
024    7_
$a 10.1186/s12938-016-0191-0 $2 doi
035    __
$a (PubMed)27206477
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a enk
100    1_
$a Kolar, Radim $u Department of Biomedical Engineering, Faculty of Electrical Engineering and Communication, Brno University of Technology, Technicka 12, 616 00, Brno, Czech Republic. kolarr@feec.vutbr.cz.
245    10
$a Registration of retinal sequences from new video-ophthalmoscopic camera / $c R. Kolar, RP. Tornow, J. Odstrcilik, I. Liberdova,
520    9_
$a BACKGROUND: Analysis of fast temporal changes on retinas has become an important part of diagnostic video-ophthalmology. It enables investigation of the hemodynamic processes in retinal tissue, e.g. blood-vessel diameter changes as a result of blood-pressure variation, spontaneous venous pulsation influenced by intracranial-intraocular pressure difference, blood-volume changes as a result of changes in light reflection from retinal tissue, and blood flow using laser speckle contrast imaging. For such applications, image registration of the recorded sequence must be performed. METHODS: Here we use a new non-mydriatic video-ophthalmoscope for simple and fast acquisition of low SNR retinal sequences. We introduce a novel, two-step approach for fast image registration. The phase correlation in the first stage removes large eye movements. Lucas-Kanade tracking in the second stage removes small eye movements. We propose robust adaptive selection of the tracking points, which is the most important part of tracking-based approaches. We also describe a method for quantitative evaluation of the registration results, based on vascular tree intensity profiles. RESULTS: The achieved registration error evaluated on 23 sequences (5840 frames) is 0.78 ± 0.67 pixels inside the optic disc and 1.39 ± 0.63 pixels outside the optic disc. We compared the results with the commonly used approaches based on Lucas-Kanade tracking and scale-invariant feature transform, which achieved worse results. CONCLUSION: The proposed method can efficiently correct particular frames of retinal sequences for shift and rotation. The registration results for each frame (shift in X and Y direction and eye rotation) can also be used for eye-movement evaluation during single-spot fixation tasks.
650    _2
$a algoritmy $7 D000465
650    _2
$a pohyby očí $7 D005133
650    _2
$a lidé $7 D006801
650    _2
$a počítačové zpracování obrazu $x metody $7 D007091
650    12
$a oftalmoskopy $7 D019721
650    12
$a retina $x fyziologie $7 D012160
650    _2
$a retinální cévy $x cytologie $7 D012171
650    _2
$a poměr signál - šum $7 D059629
650    _2
$a videozáznam $7 D014743
655    _2
$a časopisecké články $7 D016428
700    1_
$a Tornow, Ralf P $u Department of Ophthalmology, Friedrich-Alexander-University Erlangen-Nürnberg, Schwabachanlage 6, 91054, Erlangen, Germany.
700    1_
$a Odstrcilik, Jan $u Department of Biomedical Engineering, Faculty of Electrical Engineering and Communication, Brno University of Technology, Technicka 12, 616 00, Brno, Czech Republic.
700    1_
$a Liberdova, Ivana $u Department of Biomedical Engineering, Faculty of Electrical Engineering and Communication, Brno University of Technology, Technicka 12, 616 00, Brno, Czech Republic.
773    0_
$w MED00008166 $t Biomedical engineering online $x 1475-925X $g Roč. 15, č. 1 (2016), s. 57
856    41
$u https://pubmed.ncbi.nlm.nih.gov/27206477 $y Pubmed
910    __
$a ABA008 $b sig $c sign $y a $z 0
990    __
$a 20170413 $b ABA008
991    __
$a 20170418110133 $b ABA008
999    __
$a ok $b bmc $g 1200307 $s 974620
BAS    __
$a 3
BAS    __
$a PreBMC
BMC    __
$a 2016 $b 15 $c 1 $d 57 $e 20160520 $i 1475-925X $m Biomedical engineering online $n Biomed Eng Online $x MED00008166
LZP    __
$a Pubmed-20170413

Find record

Citation metrics

Loading data ...

Archiving options

Loading data ...