Threshold for diagnosing hypertension by automated office blood pressure using random sample population data
P. Wohlfahrt, R. Cífková, N. Movsisyan, Š. Kunzová, J. Lešovský, M. Homolka, V. Soška, H. Bauerová, F. Lopez-Jimenez, O. Sochor,
Language English Country England, Great Britain
Document type Journal Article
Grant support
NT13434
MZ0
CEP Register
NV15-27109A
MZ0
CEP Register
- MeSH
- Algorithms MeSH
- Adult MeSH
- Hypertension diagnosis MeSH
- Blood Pressure * MeSH
- Middle Aged MeSH
- Humans MeSH
- Masked Hypertension diagnosis MeSH
- Blood Pressure Determination instrumentation methods MeSH
- Predictive Value of Tests MeSH
- Reference Values MeSH
- Sphygmomanometers MeSH
- White Coat Hypertension diagnosis MeSH
- Check Tag
- Adult MeSH
- Middle Aged MeSH
- Humans MeSH
- Male MeSH
- Female MeSH
- Publication type
- Journal Article MeSH
OBJECTIVE: Manual office blood pressure (BP) is still recommended for diagnosing hypertension. However, its predictive value is decreased by errors in measurement technique and the white-coat effect. The errors can be eliminated by automated office BP (AOBP) measurement taking multiple readings with the participant resting quietly alone. Therefore, use of AOBP in clinical practice requires a threshold value for hypertension diagnosis. The aim of the present study was to determine an AOBP threshold corresponding to the 140/90 mmHg manual office BP using data from a large random population sample. METHODS: In 2145 participants (mean age 47.3 ± 11.3 years) randomly selected from a Brno population aged 25-64 years, BP was measured using manual mercury and automated office sphygmomanometers. RESULTS: Manual SBP (mean difference 6.39 ± 9.76 mmHg) and DBP (mean difference 2.50 ± 6.54 mmHg) were higher than the automated BP. According to polynomial regression, automated systole of 131.06 (95% confidence interval 130.43-131.70) and diastole of 85.43 (95% confidence interval 85.03-85.82) corresponded to the manual BP of 140/90 mmHg. Using this cut-off, the white-coat hypertension was present in 24% of participants with elevated manual BP, whereas 10% had masked hypertension and 11% masked uncontrolled hypertension. In individuals with masked uncontrolled hypertension, only AOBP was associated with the urinary albumin-creatinine ratio, whereas there was no association with manual BP. CONCLUSION: AOBP of 131/85 mmHg corresponds to the manual BP of 140/90 mmHg. This value may be used as a threshold for diagnosing hypertension using AOBP. However, outcome-driven studies are required to confirm this threshold.
References provided by Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc17031516
- 003
- CZ-PrNML
- 005
- 20190917123711.0
- 007
- ta
- 008
- 171025s2016 enk f 000 0|eng||
- 009
- AR
- 024 7_
- $a 10.1097/HJH.0000000000001076 $2 doi
- 035 __
- $a (PubMed)27512968
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a enk
- 100 1_
- $a Wohlfahrt, Peter $u aInternational Clinical Research Center, St. Anne's University Hospital, Brno bCenter for Cardiovascular Prevention of the First Faculty of Medicine, Charles University and Thomayer Hospital cLaboratory for Atherosclerosis Research, Institute for Clinical and Experimental Medicine, Prague dDepartment of Laboratory Methods, Masaryk University, Brno, Czech Republic eDivision of Cardiovascular Diseases, Mayo Clinic, Rochester, Minnesota, USA.
- 245 10
- $a Threshold for diagnosing hypertension by automated office blood pressure using random sample population data / $c P. Wohlfahrt, R. Cífková, N. Movsisyan, Š. Kunzová, J. Lešovský, M. Homolka, V. Soška, H. Bauerová, F. Lopez-Jimenez, O. Sochor,
- 520 9_
- $a OBJECTIVE: Manual office blood pressure (BP) is still recommended for diagnosing hypertension. However, its predictive value is decreased by errors in measurement technique and the white-coat effect. The errors can be eliminated by automated office BP (AOBP) measurement taking multiple readings with the participant resting quietly alone. Therefore, use of AOBP in clinical practice requires a threshold value for hypertension diagnosis. The aim of the present study was to determine an AOBP threshold corresponding to the 140/90 mmHg manual office BP using data from a large random population sample. METHODS: In 2145 participants (mean age 47.3 ± 11.3 years) randomly selected from a Brno population aged 25-64 years, BP was measured using manual mercury and automated office sphygmomanometers. RESULTS: Manual SBP (mean difference 6.39 ± 9.76 mmHg) and DBP (mean difference 2.50 ± 6.54 mmHg) were higher than the automated BP. According to polynomial regression, automated systole of 131.06 (95% confidence interval 130.43-131.70) and diastole of 85.43 (95% confidence interval 85.03-85.82) corresponded to the manual BP of 140/90 mmHg. Using this cut-off, the white-coat hypertension was present in 24% of participants with elevated manual BP, whereas 10% had masked hypertension and 11% masked uncontrolled hypertension. In individuals with masked uncontrolled hypertension, only AOBP was associated with the urinary albumin-creatinine ratio, whereas there was no association with manual BP. CONCLUSION: AOBP of 131/85 mmHg corresponds to the manual BP of 140/90 mmHg. This value may be used as a threshold for diagnosing hypertension using AOBP. However, outcome-driven studies are required to confirm this threshold.
- 650 _2
- $a dospělí $7 D000328
- 650 _2
- $a algoritmy $7 D000465
- 650 12
- $a krevní tlak $7 D001794
- 650 _2
- $a měření krevního tlaku $x přístrojové vybavení $x metody $7 D001795
- 650 _2
- $a ženské pohlaví $7 D005260
- 650 _2
- $a lidé $7 D006801
- 650 _2
- $a hypertenze $x diagnóza $7 D006973
- 650 _2
- $a mužské pohlaví $7 D008297
- 650 _2
- $a maskovaná hypertenze $x diagnóza $7 D059468
- 650 _2
- $a lidé středního věku $7 D008875
- 650 _2
- $a prediktivní hodnota testů $7 D011237
- 650 _2
- $a referenční hodnoty $7 D012016
- 650 _2
- $a sfygmomanometry $7 D019722
- 650 _2
- $a syndrom bílého pláště $x diagnóza $7 D059466
- 655 _2
- $a časopisecké články $7 D016428
- 700 1_
- $a Cífková, Renata, $d 1955- $7 nlk20010094490
- 700 1_
- $a Movsisyan, Narine
- 700 1_
- $a Kunzová, Šárka $7 _AN070609
- 700 1_
- $a Lešovský, Jiří $7 _AN080342
- 700 1_
- $a Homolka, Martin $7 xx0278728
- 700 1_
- $a Soška, Vladimír, $d 1953- $7 nlk20020120980
- 700 1_
- $a Bauerová, Hana
- 700 1_
- $a Lopez-Jimenez, Francisco
- 700 1_
- $a Sochor, Ondřej $7 xx0131606
- 773 0_
- $w MED00002723 $t Journal of hypertension $x 1473-5598 $g Roč. 34, č. 11 (2016), s. 2180-2186
- 856 41
- $u https://pubmed.ncbi.nlm.nih.gov/27512968 $y Pubmed
- 910 __
- $a ABA008 $b sig $c sign $y a $z 0
- 990 __
- $a 20171025 $b ABA008
- 991 __
- $a 20190917124059 $b ABA008
- 999 __
- $a ok $b bmc $g 1255109 $s 992543
- BAS __
- $a 3
- BAS __
- $a PreBMC
- BMC __
- $a 2016 $b 34 $c 11 $d 2180-2186 $i 1473-5598 $m Journal of hypertension $n J Hypertens $x MED00002723
- GRA __
- $a NT13434 $p MZ0
- GRA __
- $a NV15-27109A $p MZ0
- LZP __
- $a Pubmed-20171025