-
Je něco špatně v tomto záznamu ?
Sensitivity and Kinetics of an NS1-Based Zika Virus Enzyme-Linked Immunosorbent Assay in Zika Virus-Infected Travelers from Israel, the Czech Republic, Italy, Belgium, Germany, and Chile
Y. Lustig, H. Zelena, G. Venturi, M. Van Esbroeck, C. Rothe, C. Perret, R. Koren, S. Katz-Likvornik, E. Mendelson, E. Schwartz,
Jazyk angličtina Země Spojené státy americké
Typ dokumentu hodnotící studie, časopisecké články
NLK
Free Medical Journals
od 1975 do Před 6 měsíci
Freely Accessible Science Journals
od 1995 do Před 6 měsíci
PubMed Central
od 1975 do Před 1 rokem
Europe PubMed Central
od 1975 do Před 6 měsíci
Open Access Digital Library
od 1975-01-01
Open Access Digital Library
od 1975-01-01
PubMed
28381608
DOI
10.1128/jcm.00346-17
Knihovny.cz E-zdroje
- MeSH
- časové faktory MeSH
- cestování MeSH
- dítě MeSH
- dospělí MeSH
- ELISA metody MeSH
- importované infekce diagnóza MeSH
- imunoglobulin G krev MeSH
- imunoglobulin M krev MeSH
- infekce virem zika diagnóza MeSH
- lidé středního věku MeSH
- lidé MeSH
- mladiství MeSH
- mladý dospělý MeSH
- předškolní dítě MeSH
- protilátky virové krev MeSH
- senioři MeSH
- senzitivita a specificita MeSH
- sérologické testy metody MeSH
- tvorba protilátek MeSH
- virové nestrukturální proteiny imunologie MeSH
- Check Tag
- dítě MeSH
- dospělí MeSH
- lidé středního věku MeSH
- lidé MeSH
- mladiství MeSH
- mladý dospělý MeSH
- mužské pohlaví MeSH
- předškolní dítě MeSH
- senioři MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- hodnotící studie MeSH
- Geografické názvy
- Chile MeSH
- Evropa MeSH
Serological diagnosis of Zika virus is challenging due to high cross-reactivity of Zika virus with other flavivirus antibodies. Recently, a Zika NS1-based enzyme-linked immunosorbent assay (ELISA) was developed and shown to be highly specific for Zika antibody detection; however, sensitivity was evaluated for only a small number of confirmed Zika-infected patients. In this study, we measured the sensitivity and kinetics of Zika IgM and IgG antibodies using the Zika NS1-based ELISA in 105 samples from 63 returning travelers infected with Zika virus (proven by PCR or neutralization assay) from Israel, Czech Republic, Italy, Belgium, Germany, and Chile. Zika virus IgM was detected from 2 to 42 days post-symptom onset (PSO) with an overall sensitivity of 79% in the first month and 68% until 2 months PSO, while IgG antibodies were detected from 5 days to 3 years PSO with 79% sensitivity. Interestingly, significant differences in IgM sensitivity and IgM detection period were observed between Israeli and European/Chilean Zika-infected travelers, adding to the complexity of Zika infection diagnosis and suggesting that other diagnostic methods should be complemented to reduce false-negative results.
Central Virology Laboratory Ministry of Health Ramat Gan Israel
Department of Clinical Sciences Institute of Tropical Medicine Antwerp Belgium
Istituto Superiore di Sanità Rome Italy
Laboratory of Virology School of Medicine Pontificia Universidad Catolica de Chile Santiago Chile
Citace poskytuje Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc18010699
- 003
- CZ-PrNML
- 005
- 20180416144353.0
- 007
- ta
- 008
- 180404s2017 xxu f 000 0|eng||
- 009
- AR
- 024 7_
- $a 10.1128/JCM.00346-17 $2 doi
- 035 __
- $a (PubMed)28381608
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a xxu
- 100 1_
- $a Lustig, Yaniv $u Central Virology Laboratory, Ministry of Health, Ramat-Gan, Israel yaniv.lustig@sheba.health.gov.il.
- 245 10
- $a Sensitivity and Kinetics of an NS1-Based Zika Virus Enzyme-Linked Immunosorbent Assay in Zika Virus-Infected Travelers from Israel, the Czech Republic, Italy, Belgium, Germany, and Chile / $c Y. Lustig, H. Zelena, G. Venturi, M. Van Esbroeck, C. Rothe, C. Perret, R. Koren, S. Katz-Likvornik, E. Mendelson, E. Schwartz,
- 520 9_
- $a Serological diagnosis of Zika virus is challenging due to high cross-reactivity of Zika virus with other flavivirus antibodies. Recently, a Zika NS1-based enzyme-linked immunosorbent assay (ELISA) was developed and shown to be highly specific for Zika antibody detection; however, sensitivity was evaluated for only a small number of confirmed Zika-infected patients. In this study, we measured the sensitivity and kinetics of Zika IgM and IgG antibodies using the Zika NS1-based ELISA in 105 samples from 63 returning travelers infected with Zika virus (proven by PCR or neutralization assay) from Israel, Czech Republic, Italy, Belgium, Germany, and Chile. Zika virus IgM was detected from 2 to 42 days post-symptom onset (PSO) with an overall sensitivity of 79% in the first month and 68% until 2 months PSO, while IgG antibodies were detected from 5 days to 3 years PSO with 79% sensitivity. Interestingly, significant differences in IgM sensitivity and IgM detection period were observed between Israeli and European/Chilean Zika-infected travelers, adding to the complexity of Zika infection diagnosis and suggesting that other diagnostic methods should be complemented to reduce false-negative results.
- 650 _2
- $a mladiství $7 D000293
- 650 _2
- $a dospělí $7 D000328
- 650 _2
- $a senioři $7 D000368
- 650 _2
- $a protilátky virové $x krev $7 D000914
- 650 _2
- $a tvorba protilátek $7 D000917
- 650 _2
- $a dítě $7 D002648
- 650 _2
- $a předškolní dítě $7 D002675
- 650 _2
- $a Chile $7 D002677
- 650 _2
- $a importované infekce $x diagnóza $7 D000076263
- 650 _2
- $a ELISA $x metody $7 D004797
- 650 _2
- $a Evropa $7 D005060
- 650 _2
- $a ženské pohlaví $7 D005260
- 650 _2
- $a lidé $7 D006801
- 650 _2
- $a imunoglobulin G $x krev $7 D007074
- 650 _2
- $a imunoglobulin M $x krev $7 D007075
- 650 _2
- $a mužské pohlaví $7 D008297
- 650 _2
- $a lidé středního věku $7 D008875
- 650 _2
- $a senzitivita a specificita $7 D012680
- 650 _2
- $a sérologické testy $x metody $7 D012698
- 650 _2
- $a časové faktory $7 D013997
- 650 _2
- $a cestování $7 D014195
- 650 _2
- $a virové nestrukturální proteiny $x imunologie $7 D017361
- 650 _2
- $a mladý dospělý $7 D055815
- 650 _2
- $a infekce virem zika $x diagnóza $7 D000071243
- 655 _2
- $a hodnotící studie $7 D023362
- 655 _2
- $a časopisecké články $7 D016428
- 700 1_
- $a Zelena, Hana $u Institute of Public Health, Ostrava, Czech Republic. University of Defence, Faculty of Military Health Sciences, Hradec Králové, Czech Republic.
- 700 1_
- $a Venturi, Giulietta $u Istituto Superiore di Sanità, Rome, Italy.
- 700 1_
- $a Van Esbroeck, Marjan $u Department of Clinical Sciences, Institute of Tropical Medicine, Antwerp, Belgium.
- 700 1_
- $a Rothe, Camilla $u University Medical Centre Hamburg-Eppendorf, Department of Medicine, Division of Infectious Diseases and Tropical Medicine, Hamburg, Germany.
- 700 1_
- $a Perret, Cecilia $u Laboratory of Virology, School of Medicine, Pontificia Universidad Catolica de Chile, Santiago, Chile.
- 700 1_
- $a Koren, Ravit $u Central Virology Laboratory, Ministry of Health, Ramat-Gan, Israel.
- 700 1_
- $a Katz-Likvornik, Shiri $u Central Virology Laboratory, Ministry of Health, Ramat-Gan, Israel.
- 700 1_
- $a Mendelson, Ella $u Central Virology Laboratory, Ministry of Health, Ramat-Gan, Israel. Sackler Faculty of Medicine, Tel-Aviv University, Tel-Aviv, Israel.
- 700 1_
- $a Schwartz, Eli $u Sackler Faculty of Medicine, Tel-Aviv University, Tel-Aviv, Israel. Institute of Tropical & Travel Medicine, Sheba Medical Center, Tel Hashomer, Ramat-Gan, Israel.
- 773 0_
- $w MED00002592 $t Journal of clinical microbiology $x 1098-660X $g Roč. 55, č. 6 (2017), s. 1894-1901
- 856 41
- $u https://pubmed.ncbi.nlm.nih.gov/28381608 $y Pubmed
- 910 __
- $a ABA008 $b sig $c sign $y a $z 0
- 990 __
- $a 20180404 $b ABA008
- 991 __
- $a 20180416144450 $b ABA008
- 999 __
- $a ok $b bmc $g 1288184 $s 1007511
- BAS __
- $a 3
- BAS __
- $a PreBMC
- BMC __
- $a 2017 $b 55 $c 6 $d 1894-1901 $e 20170405 $i 1098-660X $m Journal of clinical microbiology $n J Clin Microbiol $x MED00002592
- LZP __
- $a Pubmed-20180404