Noninvasive assessment of cardiac output by brachial occlusion-cuff technique: comparison with the open-circuit acetylene washin method

P. Sajgalik, V. Kremen, AR. Carlson, V. Fabian, CH. Kim, C. Wheatley, V. Gerla, JA. Schirger, TP. Olson, BD. Johnson,

. 2016 ; 121 (6) : 1319-1325. [pub] 20161020

Jazyk angličtina Země Spojené státy americké

Typ dokumentu časopisecké články

Perzistentní odkaz   https://www.medvik.cz/link/bmc18016947

Cardiac output (CO) assessment as a basic hemodynamic parameter has been of interest in exercise physiology, cardiology, and anesthesiology. Noninvasive techniques available are technically challenging, and thus difficult to use outside of a clinical or laboratory setting. We propose a novel method of noninvasive CO assessment using a single, upper-arm cuff. The method uses the arterial pressure pulse wave signal acquired from the brachial artery during 20-s intervals of suprasystolic occlusion. This method was evaluated in a cohort of 12 healthy individuals (age, 27.7 ± 5.4 yr, 50% men) and compared with an established method for noninvasive CO assessment, the open-circuit acetylene method (OpCirc) at rest, and during low- to moderate-intensity exercise. CO increased from rest to exercise (rest, 7.4 ± 0.8 vs. 7.2 ± 0.8; low, 9.8 ± 1.8 vs. 9.9 ± 2.0; moderate, 14.1 ± 2.8 vs. 14.8 ± 3.2 l/min) as assessed by the cuff-occlusion and OpCirc techniques, respectively. The average error of experimental technique compared with OpCirc was -0.25 ± 1.02 l/min, Pearson's correlation coefficient of 0.96 (rest + exercise), and 0.21 ± 0.42 l/min with Pearson's correlation coefficient of 0.87 (rest only). Bland-Altman analysis demonstrated good agreement between methods (within 95% boundaries); the reproducibility coefficient (RPC) = 0.84 l/min with R2 = 0.75 at rest and RPC = 2 l/min with R2 = 0.92 at rest and during exercise, respectively. In comparison with an established method to quantify CO, the cuff-occlusion method provides similar measures at rest and with light to moderate exercise. Thus, we believe this method has the potential to be used as a new, noninvasive method for assessing CO during exercise.

Citace poskytuje Crossref.org

000      
00000naa a2200000 a 4500
001      
bmc18016947
003      
CZ-PrNML
005      
20180517140905.0
007      
ta
008      
180515s2016 xxu f 000 0|eng||
009      
AR
024    7_
$a 10.1152/japplphysiol.00981.2015 $2 doi
035    __
$a (PubMed)27765846
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a xxu
100    1_
$a Sajgalik, Pavol $u Department of Internal Medicine; Division of Cardiovascular Diseases, Mayo Clinic & Foundation, Rochester, Minnesota; Sajgalik.Pavol@mayo.edu. 1st Department of Internal Medicine, Cardio Angiology-International Clinical Research Center, Masaryk University; Brno, Czech Republic.
245    10
$a Noninvasive assessment of cardiac output by brachial occlusion-cuff technique: comparison with the open-circuit acetylene washin method / $c P. Sajgalik, V. Kremen, AR. Carlson, V. Fabian, CH. Kim, C. Wheatley, V. Gerla, JA. Schirger, TP. Olson, BD. Johnson,
520    9_
$a Cardiac output (CO) assessment as a basic hemodynamic parameter has been of interest in exercise physiology, cardiology, and anesthesiology. Noninvasive techniques available are technically challenging, and thus difficult to use outside of a clinical or laboratory setting. We propose a novel method of noninvasive CO assessment using a single, upper-arm cuff. The method uses the arterial pressure pulse wave signal acquired from the brachial artery during 20-s intervals of suprasystolic occlusion. This method was evaluated in a cohort of 12 healthy individuals (age, 27.7 ± 5.4 yr, 50% men) and compared with an established method for noninvasive CO assessment, the open-circuit acetylene method (OpCirc) at rest, and during low- to moderate-intensity exercise. CO increased from rest to exercise (rest, 7.4 ± 0.8 vs. 7.2 ± 0.8; low, 9.8 ± 1.8 vs. 9.9 ± 2.0; moderate, 14.1 ± 2.8 vs. 14.8 ± 3.2 l/min) as assessed by the cuff-occlusion and OpCirc techniques, respectively. The average error of experimental technique compared with OpCirc was -0.25 ± 1.02 l/min, Pearson's correlation coefficient of 0.96 (rest + exercise), and 0.21 ± 0.42 l/min with Pearson's correlation coefficient of 0.87 (rest only). Bland-Altman analysis demonstrated good agreement between methods (within 95% boundaries); the reproducibility coefficient (RPC) = 0.84 l/min with R2 = 0.75 at rest and RPC = 2 l/min with R2 = 0.92 at rest and during exercise, respectively. In comparison with an established method to quantify CO, the cuff-occlusion method provides similar measures at rest and with light to moderate exercise. Thus, we believe this method has the potential to be used as a new, noninvasive method for assessing CO during exercise.
650    _2
$a acetylen $x farmakologie $7 D000114
650    _2
$a dospělí $7 D000328
650    _2
$a krevní tlak $x účinky léků $x fyziologie $7 D001794
650    _2
$a arteria brachialis $x účinky léků $x fyziologie $7 D001916
650    _2
$a minutový srdeční výdej $x účinky léků $x fyziologie $7 D002302
650    _2
$a cvičení $x fyziologie $7 D015444
650    _2
$a ženské pohlaví $7 D005260
650    _2
$a lidé $7 D006801
650    _2
$a mužské pohlaví $7 D008297
650    _2
$a reprodukovatelnost výsledků $7 D015203
650    _2
$a odpočinek $x fyziologie $7 D012146
655    _2
$a časopisecké články $7 D016428
700    1_
$a Kremen, Vaclav $u Department of Internal Medicine; Division of Cardiovascular Diseases, Mayo Clinic & Foundation, Rochester, Minnesota. Czech Institute of Informatics, Robotics, and Cybernetics, Czech Technical University in Prague, Prague, Czech Republic; and.
700    1_
$a Carlson, Alex R $u Department of Internal Medicine; Division of Cardiovascular Diseases, Mayo Clinic & Foundation, Rochester, Minnesota.
700    1_
$a Fabian, Vratislav $u Department of Physics, Czech Technical University in Prague, Prague, Czech Republic.
700    1_
$a Kim, Chul-Ho $u Department of Internal Medicine; Division of Cardiovascular Diseases, Mayo Clinic & Foundation, Rochester, Minnesota.
700    1_
$a Wheatley, Courtney $u Department of Internal Medicine; Division of Cardiovascular Diseases, Mayo Clinic & Foundation, Rochester, Minnesota.
700    1_
$a Gerla, Vaclav $u Czech Institute of Informatics, Robotics, and Cybernetics, Czech Technical University in Prague, Prague, Czech Republic; and.
700    1_
$a Schirger, John A $u Department of Internal Medicine; Division of Cardiovascular Diseases, Mayo Clinic & Foundation, Rochester, Minnesota.
700    1_
$a Olson, Thomas P $u Department of Internal Medicine; Division of Cardiovascular Diseases, Mayo Clinic & Foundation, Rochester, Minnesota.
700    1_
$a Johnson, Bruce D $u Department of Internal Medicine; Division of Cardiovascular Diseases, Mayo Clinic & Foundation, Rochester, Minnesota.
773    0_
$w MED00002527 $t Journal of applied physiology (Bethesda, Md. 1985) $x 1522-1601 $g Roč. 121, č. 6 (2016), s. 1319-1325
856    41
$u https://pubmed.ncbi.nlm.nih.gov/27765846 $y Pubmed
910    __
$a ABA008 $b sig $c sign $y a $z 0
990    __
$a 20180515 $b ABA008
991    __
$a 20180517141042 $b ABA008
999    __
$a ok $b bmc $g 1300571 $s 1013787
BAS    __
$a 3
BAS    __
$a PreBMC
BMC    __
$a 2016 $b 121 $c 6 $d 1319-1325 $e 20161020 $i 1522-1601 $m Journal of applied physiology (1985) $n J Appl Physiol $x MED00002527
LZP    __
$a Pubmed-20180515

Najít záznam

Citační ukazatele

Nahrávání dat ...

Možnosti archivace

Nahrávání dat ...