-
Something wrong with this record ?
Noninvasive assessment of cardiac output by brachial occlusion-cuff technique: comparison with the open-circuit acetylene washin method
P. Sajgalik, V. Kremen, AR. Carlson, V. Fabian, CH. Kim, C. Wheatley, V. Gerla, JA. Schirger, TP. Olson, BD. Johnson,
Language English Country United States
Document type Journal Article
NLK
Free Medical Journals
from 1998 to 1 year ago
Freely Accessible Science Journals
from 1998 to 1 year ago
Open Access Digital Library
from 1996-10-01
- MeSH
- Acetylene pharmacology MeSH
- Brachial Artery drug effects physiology MeSH
- Exercise physiology MeSH
- Adult MeSH
- Blood Pressure drug effects physiology MeSH
- Humans MeSH
- Cardiac Output drug effects physiology MeSH
- Rest physiology MeSH
- Reproducibility of Results MeSH
- Check Tag
- Adult MeSH
- Humans MeSH
- Male MeSH
- Female MeSH
- Publication type
- Journal Article MeSH
Cardiac output (CO) assessment as a basic hemodynamic parameter has been of interest in exercise physiology, cardiology, and anesthesiology. Noninvasive techniques available are technically challenging, and thus difficult to use outside of a clinical or laboratory setting. We propose a novel method of noninvasive CO assessment using a single, upper-arm cuff. The method uses the arterial pressure pulse wave signal acquired from the brachial artery during 20-s intervals of suprasystolic occlusion. This method was evaluated in a cohort of 12 healthy individuals (age, 27.7 ± 5.4 yr, 50% men) and compared with an established method for noninvasive CO assessment, the open-circuit acetylene method (OpCirc) at rest, and during low- to moderate-intensity exercise. CO increased from rest to exercise (rest, 7.4 ± 0.8 vs. 7.2 ± 0.8; low, 9.8 ± 1.8 vs. 9.9 ± 2.0; moderate, 14.1 ± 2.8 vs. 14.8 ± 3.2 l/min) as assessed by the cuff-occlusion and OpCirc techniques, respectively. The average error of experimental technique compared with OpCirc was -0.25 ± 1.02 l/min, Pearson's correlation coefficient of 0.96 (rest + exercise), and 0.21 ± 0.42 l/min with Pearson's correlation coefficient of 0.87 (rest only). Bland-Altman analysis demonstrated good agreement between methods (within 95% boundaries); the reproducibility coefficient (RPC) = 0.84 l/min with R2 = 0.75 at rest and RPC = 2 l/min with R2 = 0.92 at rest and during exercise, respectively. In comparison with an established method to quantify CO, the cuff-occlusion method provides similar measures at rest and with light to moderate exercise. Thus, we believe this method has the potential to be used as a new, noninvasive method for assessing CO during exercise.
Department of Internal Medicine
Department of Physics Czech Technical University Prague Prague Czech Republic
Division of Cardiovascular Diseases Mayo Clinic and Foundation Rochester Minnesota
References provided by Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc18016947
- 003
- CZ-PrNML
- 005
- 20180517140905.0
- 007
- ta
- 008
- 180515s2016 xxu f 000 0|eng||
- 009
- AR
- 024 7_
- $a 10.1152/japplphysiol.00981.2015 $2 doi
- 035 __
- $a (PubMed)27765846
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a xxu
- 100 1_
- $a Sajgalik, Pavol $u Department of Internal Medicine; Division of Cardiovascular Diseases, Mayo Clinic & Foundation, Rochester, Minnesota; Sajgalik.Pavol@mayo.edu. 1st Department of Internal Medicine, Cardio Angiology-International Clinical Research Center, Masaryk University; Brno, Czech Republic.
- 245 10
- $a Noninvasive assessment of cardiac output by brachial occlusion-cuff technique: comparison with the open-circuit acetylene washin method / $c P. Sajgalik, V. Kremen, AR. Carlson, V. Fabian, CH. Kim, C. Wheatley, V. Gerla, JA. Schirger, TP. Olson, BD. Johnson,
- 520 9_
- $a Cardiac output (CO) assessment as a basic hemodynamic parameter has been of interest in exercise physiology, cardiology, and anesthesiology. Noninvasive techniques available are technically challenging, and thus difficult to use outside of a clinical or laboratory setting. We propose a novel method of noninvasive CO assessment using a single, upper-arm cuff. The method uses the arterial pressure pulse wave signal acquired from the brachial artery during 20-s intervals of suprasystolic occlusion. This method was evaluated in a cohort of 12 healthy individuals (age, 27.7 ± 5.4 yr, 50% men) and compared with an established method for noninvasive CO assessment, the open-circuit acetylene method (OpCirc) at rest, and during low- to moderate-intensity exercise. CO increased from rest to exercise (rest, 7.4 ± 0.8 vs. 7.2 ± 0.8; low, 9.8 ± 1.8 vs. 9.9 ± 2.0; moderate, 14.1 ± 2.8 vs. 14.8 ± 3.2 l/min) as assessed by the cuff-occlusion and OpCirc techniques, respectively. The average error of experimental technique compared with OpCirc was -0.25 ± 1.02 l/min, Pearson's correlation coefficient of 0.96 (rest + exercise), and 0.21 ± 0.42 l/min with Pearson's correlation coefficient of 0.87 (rest only). Bland-Altman analysis demonstrated good agreement between methods (within 95% boundaries); the reproducibility coefficient (RPC) = 0.84 l/min with R2 = 0.75 at rest and RPC = 2 l/min with R2 = 0.92 at rest and during exercise, respectively. In comparison with an established method to quantify CO, the cuff-occlusion method provides similar measures at rest and with light to moderate exercise. Thus, we believe this method has the potential to be used as a new, noninvasive method for assessing CO during exercise.
- 650 _2
- $a acetylen $x farmakologie $7 D000114
- 650 _2
- $a dospělí $7 D000328
- 650 _2
- $a krevní tlak $x účinky léků $x fyziologie $7 D001794
- 650 _2
- $a arteria brachialis $x účinky léků $x fyziologie $7 D001916
- 650 _2
- $a minutový srdeční výdej $x účinky léků $x fyziologie $7 D002302
- 650 _2
- $a cvičení $x fyziologie $7 D015444
- 650 _2
- $a ženské pohlaví $7 D005260
- 650 _2
- $a lidé $7 D006801
- 650 _2
- $a mužské pohlaví $7 D008297
- 650 _2
- $a reprodukovatelnost výsledků $7 D015203
- 650 _2
- $a odpočinek $x fyziologie $7 D012146
- 655 _2
- $a časopisecké články $7 D016428
- 700 1_
- $a Kremen, Vaclav $u Department of Internal Medicine; Division of Cardiovascular Diseases, Mayo Clinic & Foundation, Rochester, Minnesota. Czech Institute of Informatics, Robotics, and Cybernetics, Czech Technical University in Prague, Prague, Czech Republic; and.
- 700 1_
- $a Carlson, Alex R $u Department of Internal Medicine; Division of Cardiovascular Diseases, Mayo Clinic & Foundation, Rochester, Minnesota.
- 700 1_
- $a Fabian, Vratislav $u Department of Physics, Czech Technical University in Prague, Prague, Czech Republic.
- 700 1_
- $a Kim, Chul-Ho $u Department of Internal Medicine; Division of Cardiovascular Diseases, Mayo Clinic & Foundation, Rochester, Minnesota.
- 700 1_
- $a Wheatley, Courtney $u Department of Internal Medicine; Division of Cardiovascular Diseases, Mayo Clinic & Foundation, Rochester, Minnesota.
- 700 1_
- $a Gerla, Vaclav $u Czech Institute of Informatics, Robotics, and Cybernetics, Czech Technical University in Prague, Prague, Czech Republic; and.
- 700 1_
- $a Schirger, John A $u Department of Internal Medicine; Division of Cardiovascular Diseases, Mayo Clinic & Foundation, Rochester, Minnesota.
- 700 1_
- $a Olson, Thomas P $u Department of Internal Medicine; Division of Cardiovascular Diseases, Mayo Clinic & Foundation, Rochester, Minnesota.
- 700 1_
- $a Johnson, Bruce D $u Department of Internal Medicine; Division of Cardiovascular Diseases, Mayo Clinic & Foundation, Rochester, Minnesota.
- 773 0_
- $w MED00002527 $t Journal of applied physiology (Bethesda, Md. 1985) $x 1522-1601 $g Roč. 121, č. 6 (2016), s. 1319-1325
- 856 41
- $u https://pubmed.ncbi.nlm.nih.gov/27765846 $y Pubmed
- 910 __
- $a ABA008 $b sig $c sign $y a $z 0
- 990 __
- $a 20180515 $b ABA008
- 991 __
- $a 20180517141042 $b ABA008
- 999 __
- $a ok $b bmc $g 1300571 $s 1013787
- BAS __
- $a 3
- BAS __
- $a PreBMC
- BMC __
- $a 2016 $b 121 $c 6 $d 1319-1325 $e 20161020 $i 1522-1601 $m Journal of applied physiology (1985) $n J Appl Physiol $x MED00002527
- LZP __
- $a Pubmed-20180515