-
Something wrong with this record ?
Determination of N-(2-hydroxyethyl)valine in globin of ethylene oxide-exposed workers using total acidic hydrolysis and HPLC-ESI-MS2
J. Mráz, I. Hanzlíková, Š. Dušková, M. Tvrdíková, H. Chrástecká, R. Vajtrová, I. Linhart,
Language English Country Netherlands
Document type Journal Article
- MeSH
- Environmental Biomarkers MeSH
- Ethylene Oxide adverse effects blood MeSH
- Globins analysis MeSH
- Spectrometry, Mass, Electrospray Ionization * MeSH
- Risk Assessment MeSH
- Hydrolysis MeSH
- Occupational Health * MeSH
- Inhalation Exposure * adverse effects MeSH
- Acids chemistry MeSH
- Humans MeSH
- Environmental Monitoring methods MeSH
- Occupational Exposure * adverse effects MeSH
- Reproducibility of Results MeSH
- Valine analogs & derivatives blood MeSH
- Chromatography, High Pressure Liquid * MeSH
- Check Tag
- Humans MeSH
- Male MeSH
- Publication type
- Journal Article MeSH
Ethylene oxide (EO), an industrial intermediate and gaseous sterilant for medical devices, is carcinogenic to humans, which warrants minimization of exposure in the workplaces. The principal analytical strategy currently used in biomonitoring of exposure to EO consists in the conversion of N-(2-hydroxyethyl) adduct at the N-terminal valine (HEV) in globin to a specific thiohydantoin derivative accessible to GC-MS analysis (modified Edman degradation, MED). Though highly sensitive, the method is laborious and, at least in our hands, not sufficiently robust. Here we developed an alternative strategy of HEV determination based on acidic hydrolysis (AH) of globin followed directly by HPLC-ESI-MS2 analysis. Limit of quantitation is ca. 25 pmol HEV/g globin. Comparative analyses of globin samples from EO-exposed workers by both the AH-based and MED-based methods provided results that correlated well with each other (R2 > 0.95) but those obtained with AH were significantly more accurate (according to external quality control programme G-EQUAS) and repeatible (5% and 6% for intra-day and between-day analyses, respectively). In conclusion, the new AH-based method surpassed MED being similarly sensitive, much less laborious and more reliable, thus applicable as an effective tool for biomonitoring of EO in exposure control and risk assessment.
References provided by Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc19000622
- 003
- CZ-PrNML
- 005
- 20190121113013.0
- 007
- ta
- 008
- 190107s2018 ne f 000 0|eng||
- 009
- AR
- 024 7_
- $a 10.1016/j.toxlet.2018.06.1212 $2 doi
- 035 __
- $a (PubMed)29936296
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a ne
- 100 1_
- $a Mráz, Jaroslav $u Centre of Occupational Health, National Institute of Public Health, Šrobárova 48, 100 42 Prague, Czech Republic. Electronic address: jaroslav.mraz@szu.cz.
- 245 10
- $a Determination of N-(2-hydroxyethyl)valine in globin of ethylene oxide-exposed workers using total acidic hydrolysis and HPLC-ESI-MS2 / $c J. Mráz, I. Hanzlíková, Š. Dušková, M. Tvrdíková, H. Chrástecká, R. Vajtrová, I. Linhart,
- 520 9_
- $a Ethylene oxide (EO), an industrial intermediate and gaseous sterilant for medical devices, is carcinogenic to humans, which warrants minimization of exposure in the workplaces. The principal analytical strategy currently used in biomonitoring of exposure to EO consists in the conversion of N-(2-hydroxyethyl) adduct at the N-terminal valine (HEV) in globin to a specific thiohydantoin derivative accessible to GC-MS analysis (modified Edman degradation, MED). Though highly sensitive, the method is laborious and, at least in our hands, not sufficiently robust. Here we developed an alternative strategy of HEV determination based on acidic hydrolysis (AH) of globin followed directly by HPLC-ESI-MS2 analysis. Limit of quantitation is ca. 25 pmol HEV/g globin. Comparative analyses of globin samples from EO-exposed workers by both the AH-based and MED-based methods provided results that correlated well with each other (R2 > 0.95) but those obtained with AH were significantly more accurate (according to external quality control programme G-EQUAS) and repeatible (5% and 6% for intra-day and between-day analyses, respectively). In conclusion, the new AH-based method surpassed MED being similarly sensitive, much less laborious and more reliable, thus applicable as an effective tool for biomonitoring of EO in exposure control and risk assessment.
- 650 _2
- $a kyseliny $x chemie $7 D000143
- 650 12
- $a vysokoúčinná kapalinová chromatografie $7 D002851
- 650 _2
- $a bioindikátory $7 D000074062
- 650 _2
- $a monitorování životního prostředí $x metody $7 D004784
- 650 _2
- $a ethylenoxid $x škodlivé účinky $x krev $7 D005027
- 650 _2
- $a globiny $x analýza $7 D005914
- 650 _2
- $a lidé $7 D006801
- 650 _2
- $a hydrolýza $7 D006868
- 650 12
- $a inhalační expozice $x škodlivé účinky $7 D019570
- 650 _2
- $a mužské pohlaví $7 D008297
- 650 12
- $a pracovní expozice $x škodlivé účinky $7 D016273
- 650 12
- $a hygiena práce $7 D016272
- 650 _2
- $a reprodukovatelnost výsledků $7 D015203
- 650 _2
- $a hodnocení rizik $7 D018570
- 650 12
- $a hmotnostní spektrometrie s elektrosprejovou ionizací $7 D021241
- 650 _2
- $a valin $x analogy a deriváty $x krev $7 D014633
- 655 _2
- $a časopisecké články $7 D016428
- 700 1_
- $a Hanzlíková, Iveta $u Centre of Occupational Health, National Institute of Public Health, Šrobárova 48, 100 42 Prague, Czech Republic.
- 700 1_
- $a Dušková, Šárka $u Centre of Occupational Health, National Institute of Public Health, Šrobárova 48, 100 42 Prague, Czech Republic.
- 700 1_
- $a Tvrdíková, Monika $u Centre of Occupational Health, National Institute of Public Health, Šrobárova 48, 100 42 Prague, Czech Republic.
- 700 1_
- $a Chrástecká, Hana $u Centre of Occupational Health, National Institute of Public Health, Šrobárova 48, 100 42 Prague, Czech Republic.
- 700 1_
- $a Vajtrová, Radka $u Centre of Occupational Health, National Institute of Public Health, Šrobárova 48, 100 42 Prague, Czech Republic.
- 700 1_
- $a Linhart, Igor $u Department of Organic Chemistry, Faculty of Chemical Technology, University of Chemistry and Technology, Technická 1905, 166 28 Prague, Czech Republic.
- 773 0_
- $w MED00004537 $t Toxicology letters $x 1879-3169 $g Roč. 298, č. - (2018), s. 76-80
- 856 41
- $u https://pubmed.ncbi.nlm.nih.gov/29936296 $y Pubmed
- 910 __
- $a ABA008 $b sig $c sign $y a $z 0
- 990 __
- $a 20190107 $b ABA008
- 991 __
- $a 20190121113232 $b ABA008
- 999 __
- $a ok $b bmc $g 1364668 $s 1038745
- BAS __
- $a 3
- BAS __
- $a PreBMC
- BMC __
- $a 2018 $b 298 $c - $d 76-80 $e 20180621 $i 1879-3169 $m Toxicology letters $n Toxicol Lett $x MED00004537
- LZP __
- $a Pubmed-20190107