The determination of pharmaceutically active thiols using hydrophilic interaction chromatography followed postcolumn derivatization with o-phthaldialdehyde and fluorescence detection

M. Douša,

. 2018 ; 156 (-) : 1-7. [pub] 20180416

Jazyk angličtina Země Anglie, Velká Británie

Typ dokumentu časopisecké články, validační studie

Perzistentní odkaz   https://www.medvik.cz/link/bmc19000788

A rapid, precise and specific hydrophilic interaction chromatography (HILIC) combined with postcolumn derivatization using o-phthaldialdehyde and fluorescence detection was developed and validated for the determination of selected pharmaceutically active thiols. The analysis was carried out on a Diol HILIC column using a mobile phase consisting of acetonitrile and solution of 10 mmol/L citric acid adjusted with 1-propylamine to pH 5.5 in ratio 75:25 (v/v) for separation of cysteine and homocysteine and in ratio 85:15 (v/v) for separation of N-acetyl-l-cysteine and captopril. The postcolumn derivatization reaction was performed at room temperature using reagent (5 mmol/L OPA in 0.05 mol/L 4- (2-hydroxyethyl) piperazine-1-ethanesulfonic acid at pH 7) delivered at the flow rate of 0.3 mL/min. Fluorescence detection was carried out at excitation and emission wavelength of 345 nm and 450 nm, respectively. The effect of chromatographic conditions including acetonitrile content, salt concentration in the mobile phase and mobile phase pH on the retention of tested thiols was investigated. The postcolumn reaction conditions such as reaction temperature, derivatization reagent flow rate, o-phthaldialdehyde concentration and derivatization reagent pH were deeply studied. The developed method was validated in terms of linearity, accuracy, precision and selectivity according to the International Conference on Harmonisation guidelines. The HILIC method was successfully applied for the analysis of commercially available samples of pharmaceutically active thiols such as captopril, N-acetyl-l-cysteine (NAC) and cysteine.

Citace poskytuje Crossref.org

000      
00000naa a2200000 a 4500
001      
bmc19000788
003      
CZ-PrNML
005      
20190111145725.0
007      
ta
008      
190107s2018 enk f 000 0|eng||
009      
AR
024    7_
$a 10.1016/j.jpba.2018.04.007 $2 doi
035    __
$a (PubMed)29684906
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a enk
100    1_
$a Douša, Michal $u Zentiva, k.s. Praha, a Sanofi Company, U Kabelovny 130, 102 37 Prague 10, Czech Republic. Electronic address: michal.dousa@seznam.cz.
245    14
$a The determination of pharmaceutically active thiols using hydrophilic interaction chromatography followed postcolumn derivatization with o-phthaldialdehyde and fluorescence detection / $c M. Douša,
520    9_
$a A rapid, precise and specific hydrophilic interaction chromatography (HILIC) combined with postcolumn derivatization using o-phthaldialdehyde and fluorescence detection was developed and validated for the determination of selected pharmaceutically active thiols. The analysis was carried out on a Diol HILIC column using a mobile phase consisting of acetonitrile and solution of 10 mmol/L citric acid adjusted with 1-propylamine to pH 5.5 in ratio 75:25 (v/v) for separation of cysteine and homocysteine and in ratio 85:15 (v/v) for separation of N-acetyl-l-cysteine and captopril. The postcolumn derivatization reaction was performed at room temperature using reagent (5 mmol/L OPA in 0.05 mol/L 4- (2-hydroxyethyl) piperazine-1-ethanesulfonic acid at pH 7) delivered at the flow rate of 0.3 mL/min. Fluorescence detection was carried out at excitation and emission wavelength of 345 nm and 450 nm, respectively. The effect of chromatographic conditions including acetonitrile content, salt concentration in the mobile phase and mobile phase pH on the retention of tested thiols was investigated. The postcolumn reaction conditions such as reaction temperature, derivatization reagent flow rate, o-phthaldialdehyde concentration and derivatization reagent pH were deeply studied. The developed method was validated in terms of linearity, accuracy, precision and selectivity according to the International Conference on Harmonisation guidelines. The HILIC method was successfully applied for the analysis of commercially available samples of pharmaceutically active thiols such as captopril, N-acetyl-l-cysteine (NAC) and cysteine.
650    _2
$a acetonitrily $x chemie $7 D000097
650    _2
$a acetylcystein $x analýza $7 D000111
650    _2
$a kaptopril $x analýza $7 D002216
650    _2
$a vysokoúčinná kapalinová chromatografie $x metody $7 D002851
650    _2
$a cystein $x analýza $7 D003545
650    _2
$a hydrofobní a hydrofilní interakce $7 D057927
650    _2
$a propylaminy $7 D011437
650    _2
$a fluorescenční spektrometrie $7 D013050
650    _2
$a sulfhydrylové sloučeniny $x analýza $x chemie $7 D013438
650    _2
$a teplota $7 D013696
650    _2
$a o-ftalaldehyd $x chemie $7 D009764
655    _2
$a časopisecké články $7 D016428
655    _2
$a validační studie $7 D023361
773    0_
$w MED00002894 $t Journal of pharmaceutical and biomedical analysis $x 1873-264X $g Roč. 156, č. - (2018), s. 1-7
856    41
$u https://pubmed.ncbi.nlm.nih.gov/29684906 $y Pubmed
910    __
$a ABA008 $b sig $c sign $y a $z 0
990    __
$a 20190107 $b ABA008
991    __
$a 20190111145930 $b ABA008
999    __
$a ok $b bmc $g 1364794 $s 1038911
BAS    __
$a 3
BAS    __
$a PreBMC
BMC    __
$a 2018 $b 156 $c - $d 1-7 $e 20180416 $i 1873-264X $m Journal of pharmaceutical and biomedical analysis $n J Pharm Biomed Anal $x MED00002894
LZP    __
$a Pubmed-20190107

Najít záznam

Citační ukazatele

Pouze přihlášení uživatelé

Možnosti archivace

Nahrávání dat ...