Detail
Article
Online article
FT
Medvik - BMC
  • Something wrong with this record ?

Preparation and Characterization of Carbon Paste Electrode Bulk-Modified with Multiwalled Carbon Nanotubes and Its Application in a Sensitive Assay of Antihyperlipidemic Simvastatin in Biological Samples

AM. Ashrafi, L. Richtera,

. 2019 ; 24 (12) : . [pub] 20190613

Language English Country Switzerland

Document type Journal Article

Grant support
LO1401 Ministerstvo Školství, Mládeže a Tělovýchovy

Determination of an antihyperlipidemic drug simvastatin (SIM) was carried out using a carbon paste electrode bulk-modified with multiwalled carbon nanotubes (MWCNT-CPE). Scanning electrochemical microscopy (SECM), scanning electron microscopy (SEM), and atomic force microscopy (AFM) were used for the characterization of the prepared electrodes. Different electrodes were prepared varying in mass percentage of MWCNTs to find out the optimum amount of MWCNTs in the paste. The MWCNT-CPE in which the mass percentage of MWCNTs was 25% (w/w) was found as the optimum. Then, the prepared electrode was used in a mechanistic study and sensitive assay of SIM in pharmaceutical dosage form and a spiked human plasma sample using differential pulse voltammetry (DPV). The prepared electrode shows better sensitivity compared to the bare carbon paste and glassy carbon electrode (GCE). The detection limit and the limit of quantification were calculated to be 2.4 × 10-7 and 8 × 10-7, respectively. The reproducibility of the electrode was confirmed by the low value of the relative standard deviation (RSD% = 4.8%) when eight measurements of the same sample were carried out. Determination of SIM in pharmaceutical dosage form was successfully performed with a bias of 0.3% and relative recovery rate of 99.7%. Furthermore, the human plasma as a more complicated matrix was spiked with a known concentration of SIM and the spiking recovery rate was determined with the developed method to be 99.5%.

References provided by Crossref.org

000      
00000naa a2200000 a 4500
001      
bmc19044755
003      
CZ-PrNML
005      
20200113081256.0
007      
ta
008      
200109s2019 sz f 000 0|eng||
009      
AR
024    7_
$a 10.3390/molecules24122215 $2 doi
035    __
$a (PubMed)31200496
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a sz
100    1_
$a Ashrafi, Amir M $u Department of Microelectronics, Faculty of Electrical Engineering and Communication, Brno University of Technology, Technická 3058/10, CZ-616 00 Brno, Czech Republic. amirmansoor.ashrafi@mendelu.cz.
245    10
$a Preparation and Characterization of Carbon Paste Electrode Bulk-Modified with Multiwalled Carbon Nanotubes and Its Application in a Sensitive Assay of Antihyperlipidemic Simvastatin in Biological Samples / $c AM. Ashrafi, L. Richtera,
520    9_
$a Determination of an antihyperlipidemic drug simvastatin (SIM) was carried out using a carbon paste electrode bulk-modified with multiwalled carbon nanotubes (MWCNT-CPE). Scanning electrochemical microscopy (SECM), scanning electron microscopy (SEM), and atomic force microscopy (AFM) were used for the characterization of the prepared electrodes. Different electrodes were prepared varying in mass percentage of MWCNTs to find out the optimum amount of MWCNTs in the paste. The MWCNT-CPE in which the mass percentage of MWCNTs was 25% (w/w) was found as the optimum. Then, the prepared electrode was used in a mechanistic study and sensitive assay of SIM in pharmaceutical dosage form and a spiked human plasma sample using differential pulse voltammetry (DPV). The prepared electrode shows better sensitivity compared to the bare carbon paste and glassy carbon electrode (GCE). The detection limit and the limit of quantification were calculated to be 2.4 × 10-7 and 8 × 10-7, respectively. The reproducibility of the electrode was confirmed by the low value of the relative standard deviation (RSD% = 4.8%) when eight measurements of the same sample were carried out. Determination of SIM in pharmaceutical dosage form was successfully performed with a bias of 0.3% and relative recovery rate of 99.7%. Furthermore, the human plasma as a more complicated matrix was spiked with a known concentration of SIM and the spiking recovery rate was determined with the developed method to be 99.5%.
650    _2
$a uhlík $x chemie $7 D002244
650    12
$a elektrody $7 D004566
650    _2
$a lidé $7 D006801
650    _2
$a mikroskopie elektronová rastrovací $7 D008855
650    _2
$a nanotrubičky uhlíkové $x chemie $x ultrastruktura $7 D037742
650    _2
$a simvastatin $x chemie $7 D019821
655    _2
$a časopisecké články $7 D016428
700    1_
$a Richtera, Lukáš $u Department of Microelectronics, Faculty of Electrical Engineering and Communication, Brno University of Technology, Technická 3058/10, CZ-616 00 Brno, Czech Republic. richtera@mendelu.cz.
773    0_
$w MED00180394 $t Molecules (Basel, Switzerland) $x 1420-3049 $g Roč. 24, č. 12 (2019)
856    41
$u https://pubmed.ncbi.nlm.nih.gov/31200496 $y Pubmed
910    __
$a ABA008 $b sig $c sign $y a $z 0
990    __
$a 20200109 $b ABA008
991    __
$a 20200113081628 $b ABA008
999    __
$a ok $b bmc $g 1483024 $s 1083428
BAS    __
$a 3
BAS    __
$a PreBMC
BMC    __
$a 2019 $b 24 $c 12 $e 20190613 $i 1420-3049 $m Molecules $n Molecules $x MED00180394
GRA    __
$a LO1401 $p Ministerstvo Školství, Mládeže a Tělovýchovy
LZP    __
$a Pubmed-20200109

Find record

Citation metrics

Loading data ...

Archiving options

Loading data ...