-
Je něco špatně v tomto záznamu ?
Preparation and Characterization of Carbon Paste Electrode Bulk-Modified with Multiwalled Carbon Nanotubes and Its Application in a Sensitive Assay of Antihyperlipidemic Simvastatin in Biological Samples
AM. Ashrafi, L. Richtera,
Jazyk angličtina Země Švýcarsko
Typ dokumentu časopisecké články
Grantová podpora
LO1401
Ministerstvo Školství, Mládeže a Tělovýchovy
NLK
Directory of Open Access Journals
od 1997
Free Medical Journals
od 1997
PubMed Central
od 2001
Europe PubMed Central
od 2001
ProQuest Central
od 1997-01-01
Open Access Digital Library
od 1997-01-01
Medline Complete (EBSCOhost)
od 2009-03-01
Health & Medicine (ProQuest)
od 1997-01-01
- MeSH
- elektrody * MeSH
- lidé MeSH
- mikroskopie elektronová rastrovací MeSH
- nanotrubičky uhlíkové chemie ultrastruktura MeSH
- simvastatin chemie MeSH
- uhlík chemie MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
Determination of an antihyperlipidemic drug simvastatin (SIM) was carried out using a carbon paste electrode bulk-modified with multiwalled carbon nanotubes (MWCNT-CPE). Scanning electrochemical microscopy (SECM), scanning electron microscopy (SEM), and atomic force microscopy (AFM) were used for the characterization of the prepared electrodes. Different electrodes were prepared varying in mass percentage of MWCNTs to find out the optimum amount of MWCNTs in the paste. The MWCNT-CPE in which the mass percentage of MWCNTs was 25% (w/w) was found as the optimum. Then, the prepared electrode was used in a mechanistic study and sensitive assay of SIM in pharmaceutical dosage form and a spiked human plasma sample using differential pulse voltammetry (DPV). The prepared electrode shows better sensitivity compared to the bare carbon paste and glassy carbon electrode (GCE). The detection limit and the limit of quantification were calculated to be 2.4 × 10-7 and 8 × 10-7, respectively. The reproducibility of the electrode was confirmed by the low value of the relative standard deviation (RSD% = 4.8%) when eight measurements of the same sample were carried out. Determination of SIM in pharmaceutical dosage form was successfully performed with a bias of 0.3% and relative recovery rate of 99.7%. Furthermore, the human plasma as a more complicated matrix was spiked with a known concentration of SIM and the spiking recovery rate was determined with the developed method to be 99.5%.
Citace poskytuje Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc19044755
- 003
- CZ-PrNML
- 005
- 20200113081256.0
- 007
- ta
- 008
- 200109s2019 sz f 000 0|eng||
- 009
- AR
- 024 7_
- $a 10.3390/molecules24122215 $2 doi
- 035 __
- $a (PubMed)31200496
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a sz
- 100 1_
- $a Ashrafi, Amir M $u Department of Microelectronics, Faculty of Electrical Engineering and Communication, Brno University of Technology, Technická 3058/10, CZ-616 00 Brno, Czech Republic. amirmansoor.ashrafi@mendelu.cz.
- 245 10
- $a Preparation and Characterization of Carbon Paste Electrode Bulk-Modified with Multiwalled Carbon Nanotubes and Its Application in a Sensitive Assay of Antihyperlipidemic Simvastatin in Biological Samples / $c AM. Ashrafi, L. Richtera,
- 520 9_
- $a Determination of an antihyperlipidemic drug simvastatin (SIM) was carried out using a carbon paste electrode bulk-modified with multiwalled carbon nanotubes (MWCNT-CPE). Scanning electrochemical microscopy (SECM), scanning electron microscopy (SEM), and atomic force microscopy (AFM) were used for the characterization of the prepared electrodes. Different electrodes were prepared varying in mass percentage of MWCNTs to find out the optimum amount of MWCNTs in the paste. The MWCNT-CPE in which the mass percentage of MWCNTs was 25% (w/w) was found as the optimum. Then, the prepared electrode was used in a mechanistic study and sensitive assay of SIM in pharmaceutical dosage form and a spiked human plasma sample using differential pulse voltammetry (DPV). The prepared electrode shows better sensitivity compared to the bare carbon paste and glassy carbon electrode (GCE). The detection limit and the limit of quantification were calculated to be 2.4 × 10-7 and 8 × 10-7, respectively. The reproducibility of the electrode was confirmed by the low value of the relative standard deviation (RSD% = 4.8%) when eight measurements of the same sample were carried out. Determination of SIM in pharmaceutical dosage form was successfully performed with a bias of 0.3% and relative recovery rate of 99.7%. Furthermore, the human plasma as a more complicated matrix was spiked with a known concentration of SIM and the spiking recovery rate was determined with the developed method to be 99.5%.
- 650 _2
- $a uhlík $x chemie $7 D002244
- 650 12
- $a elektrody $7 D004566
- 650 _2
- $a lidé $7 D006801
- 650 _2
- $a mikroskopie elektronová rastrovací $7 D008855
- 650 _2
- $a nanotrubičky uhlíkové $x chemie $x ultrastruktura $7 D037742
- 650 _2
- $a simvastatin $x chemie $7 D019821
- 655 _2
- $a časopisecké články $7 D016428
- 700 1_
- $a Richtera, Lukáš $u Department of Microelectronics, Faculty of Electrical Engineering and Communication, Brno University of Technology, Technická 3058/10, CZ-616 00 Brno, Czech Republic. richtera@mendelu.cz.
- 773 0_
- $w MED00180394 $t Molecules (Basel, Switzerland) $x 1420-3049 $g Roč. 24, č. 12 (2019)
- 856 41
- $u https://pubmed.ncbi.nlm.nih.gov/31200496 $y Pubmed
- 910 __
- $a ABA008 $b sig $c sign $y a $z 0
- 990 __
- $a 20200109 $b ABA008
- 991 __
- $a 20200113081628 $b ABA008
- 999 __
- $a ok $b bmc $g 1483024 $s 1083428
- BAS __
- $a 3
- BAS __
- $a PreBMC
- BMC __
- $a 2019 $b 24 $c 12 $e 20190613 $i 1420-3049 $m Molecules $n Molecules $x MED00180394
- GRA __
- $a LO1401 $p Ministerstvo Školství, Mládeže a Tělovýchovy
- LZP __
- $a Pubmed-20200109