Mechanical and structural properties of human aortic and pulmonary allografts do not deteriorate in the first 10 years of cryopreservation and storage in nitrogen
R. Fiala, P. Kochová, T. Kubíková, R. Cimrman, Z. Tonar, J. Špatenka, O. Fabián, J. Burkert,
Jazyk angličtina Země Nizozemsko
Typ dokumentu časopisecké články
Grantová podpora
CZ.02.1.01/0.0/0.0/17_048/0007280
Ministerstvo Školství, Mládeže a Tělovýchovy
LO1506
Ministerstvo Školství, Mládeže a Tělovýchovy
LO1503
Ministerstvo Školství, Mládeže a Tělovýchovy
Progres Q39
Univerzita Karlova v Praze
- MeSH
- aortální chlopeň transplantace MeSH
- dospělí MeSH
- elastin analýza MeSH
- homologní transplantace MeSH
- kolagen analýza MeSH
- kryoprezervace metody MeSH
- lidé středního věku MeSH
- lidé MeSH
- plicní chlopeň transplantace MeSH
- tkáňové banky * MeSH
- Check Tag
- dospělí MeSH
- lidé středního věku MeSH
- lidé MeSH
- mužské pohlaví MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
The aortic and pulmonary allograft heart valves (AHV) are used in the cardiac surgery for replacing the impaired semilunar valves. They are harvested from donor hearts and cryostored in tissue banks. The expiration period was set to 5 years arbitrarily. We hypothesized that their mechanical and structural properties do not deteriorate after this period. A total of 64 human AHV (31 aortic and 33 pulmonary) of different length of cryopreservation (fresh, 0-5, 5-10, over 10 years) were sampled to different tissue strips (artery, leaflet, ventriculo-arterial junction) and tested by tensile test with loading velocity 10 mm/min until tissue rupture. Neighbouring regions of tissue were processed histologically and evaluated for elastin and collagen area fraction. The results were evaluated statistically. In aortic AHV, the physical deformation response of wall samples to stress did not changed significantly neither during the process of cryopreservation nor during the first 10 years of storage. In pulmonary AHV, the ultimate strain dropped after 5 years of cryopreservation indicating that pulmonary artery was significantly less deformable at the time of rupture. On the other hand, the ultimate stress was equal during the first 10 years of cryostorage. The changes in collagen and elastin amount in the tissue samples were not associated with mechanical impairment. Neither elasticity, stiffness and solidity nor morphology of aortic and pulmonary AHV did not change reasonably with cryopreservation and in the first 10 years of cryostorage. This evidence suggests that the expiration period might be extended in the future.
Citace poskytuje Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc19044927
- 003
- CZ-PrNML
- 005
- 20211005153320.0
- 007
- ta
- 008
- 200109s2019 ne f 000 0|eng||
- 009
- AR
- 024 7_
- $a 10.1007/s10561-019-09762-x $2 doi
- 035 __
- $a (PubMed)30903411
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a ne
- 100 1_
- $a Fiala, Radovan $u Department of Cardiovascular Surgery, Motol University Hospital, Second Faculty of Medicine, Charles University in Prague, V Úvalu 84, 150 06, Prague, Czech Republic. radovan.fiala@fnmotol.cz. $7 xx0064676
- 245 10
- $a Mechanical and structural properties of human aortic and pulmonary allografts do not deteriorate in the first 10 years of cryopreservation and storage in nitrogen / $c R. Fiala, P. Kochová, T. Kubíková, R. Cimrman, Z. Tonar, J. Špatenka, O. Fabián, J. Burkert,
- 520 9_
- $a The aortic and pulmonary allograft heart valves (AHV) are used in the cardiac surgery for replacing the impaired semilunar valves. They are harvested from donor hearts and cryostored in tissue banks. The expiration period was set to 5 years arbitrarily. We hypothesized that their mechanical and structural properties do not deteriorate after this period. A total of 64 human AHV (31 aortic and 33 pulmonary) of different length of cryopreservation (fresh, 0-5, 5-10, over 10 years) were sampled to different tissue strips (artery, leaflet, ventriculo-arterial junction) and tested by tensile test with loading velocity 10 mm/min until tissue rupture. Neighbouring regions of tissue were processed histologically and evaluated for elastin and collagen area fraction. The results were evaluated statistically. In aortic AHV, the physical deformation response of wall samples to stress did not changed significantly neither during the process of cryopreservation nor during the first 10 years of storage. In pulmonary AHV, the ultimate strain dropped after 5 years of cryopreservation indicating that pulmonary artery was significantly less deformable at the time of rupture. On the other hand, the ultimate stress was equal during the first 10 years of cryostorage. The changes in collagen and elastin amount in the tissue samples were not associated with mechanical impairment. Neither elasticity, stiffness and solidity nor morphology of aortic and pulmonary AHV did not change reasonably with cryopreservation and in the first 10 years of cryostorage. This evidence suggests that the expiration period might be extended in the future.
- 650 _2
- $a dospělí $7 D000328
- 650 _2
- $a aortální chlopeň $x transplantace $7 D001021
- 650 _2
- $a kolagen $x analýza $7 D003094
- 650 _2
- $a kryoprezervace $x metody $7 D015925
- 650 _2
- $a elastin $x analýza $7 D004549
- 650 _2
- $a ženské pohlaví $7 D005260
- 650 _2
- $a lidé $7 D006801
- 650 _2
- $a mužské pohlaví $7 D008297
- 650 _2
- $a lidé středního věku $7 D008875
- 650 _2
- $a plicní chlopeň $x transplantace $7 D011664
- 650 12
- $a tkáňové banky $7 D014015
- 650 _2
- $a homologní transplantace $7 D014184
- 655 _2
- $a časopisecké články $7 D016428
- 700 1_
- $a Kochová, Petra $u Department of Cardiovascular Surgery, Motol University Hospital, Second Faculty of Medicine, Charles University in Prague, V Úvalu 84, 150 06, Prague, Czech Republic. NTIS - New Technologies for the Information Society, Faculty of Applied Sciences, University of West Bohemia, Technická 8, Pilsen, Czech Republic.
- 700 1_
- $a Kubíková, Tereza $u Department of Histology and Embryology, Biomedical Centre, Faculty of Medicine in Pilsen, Charles University, Karlovarská 48, 301 66, Pilsen, Czech Republic.
- 700 1_
- $a Cimrman, Robert $u NTIS - New Technologies for the Information Society, Faculty of Applied Sciences, University of West Bohemia, Technická 8, Pilsen, Czech Republic.
- 700 1_
- $a Tonar, Zbyněk $u NTIS - New Technologies for the Information Society, Faculty of Applied Sciences, University of West Bohemia, Technická 8, Pilsen, Czech Republic.
- 700 1_
- $a Špatenka, Jaroslav $u Department of Cardiovascular Surgery, Motol University Hospital, Second Faculty of Medicine, Charles University in Prague, V Úvalu 84, 150 06, Prague, Czech Republic. Department of Transplantations and Tissue Bank, Motol University Hospital, V Úvalu 84, 150 06, Prague, Czech Republic.
- 700 1_
- $a Fabián, Ondřej $u Department of Pathology and Molecular Medicine, Motol University Hospital, Second Faculty of Medicine, Charles University in Prague, V Úvalu 84, 150 06, Prague, Czech Republic.
- 700 1_
- $a Burkert, Jan $u Department of Cardiovascular Surgery, Motol University Hospital, Second Faculty of Medicine, Charles University in Prague, V Úvalu 84, 150 06, Prague, Czech Republic. Department of Transplantations and Tissue Bank, Motol University Hospital, V Úvalu 84, 150 06, Prague, Czech Republic.
- 773 0_
- $w MED00007567 $t Cell and tissue banking $x 1573-6814 $g Roč. 20, č. 2 (2019), s. 221-241
- 856 41
- $u https://pubmed.ncbi.nlm.nih.gov/30903411 $y Pubmed
- 910 __
- $a ABA008 $b sig $c sign $y a $z 0
- 990 __
- $a 20200109 $b ABA008
- 991 __
- $a 20211005153317 $b ABA008
- 999 __
- $a ok $b bmc $g 1483196 $s 1083600
- BAS __
- $a 3
- BAS __
- $a PreBMC
- BMC __
- $a 2019 $b 20 $c 2 $d 221-241 $e 20190322 $i 1573-6814 $m Cell and tissue banking $n Cell Tissue Bank $x MED00007567
- GRA __
- $a CZ.02.1.01/0.0/0.0/17_048/0007280 $p Ministerstvo Školství, Mládeže a Tělovýchovy
- GRA __
- $a LO1506 $p Ministerstvo Školství, Mládeže a Tělovýchovy
- GRA __
- $a LO1503 $p Ministerstvo Školství, Mládeže a Tělovýchovy
- GRA __
- $a Progres Q39 $p Univerzita Karlova v Praze
- LZP __
- $a Pubmed-20200109