  • Something wrong with this record ?

Extended Timed Up & Go test: Is walking forward and returning back to the chair equivalent gait?

S. Viteckova, V. Cejka, P. Dusek, R. Krupicka, P. Kutilek, Z. Szabo, E. Růžička,

. 2019 ; 89 (-) : 110-114. [pub] 20190410

Language English Country United States

Document type Journal Article

Grant support
NV16-28119A MZ0 CEP Register

Digital library NLK
Full text - Article

E-resources Online Full text

NLK ProQuest Central from 2003-01-01 to 2 months ago
Health & Medicine (ProQuest) from 2003-01-01 to 2 months ago

The Timed Up & Go test (TUG) is functional test and is a part of routine clinical examinations. The instrumented Timed Up & Go test enables its segmentation to sub-tasks: sit-to-stand, walking forward, turning, walking back, stand-to-sit, and consequently the computation of task-specific parameters and sub-tasks separately. However, there are no data on whether walking forward parameters differ from the walking back parameters. This study tested the differences between walking forward and walking back in the TUG extended to 10 m for 17 spatio-temporal gait parameters. All parameters were obtained from a GAITRite® pressure sensitive walkway (CIR Systems, Inc.). The differences were assessed for healthy controls and Parkinson's disease (PD) patients. None of investigated parameters exhibited a difference between both gait subtasks for healthy subjects group. Five parameters of interest, namely velocity, step length, stride length, stride velocity, and the proportion of the double support phase with respect to gait cycle duration, showed a statistically significant difference between gait for walking forward and walking back in PD patients. Therefore, we recommend a separate assessment for walking forward and walking back rather than averaging both gaits together.

References provided by Crossref.org

000      
00000naa a2200000 a 4500
001      
bmc20025848
003      
CZ-PrNML
005      
20201222155507.0
007      
ta
008      
201125s2019 xxu f 000 0|eng||
009      
AR
024    7_
$a 10.1016/j.jbiomech.2019.04.001 $2 doi
035    __
$a (PubMed)30982536
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a xxu
100    1_
$a Viteckova, Slavka $u Faculty of Biomedical Engineering, Czech Technical University in Prague, nam Sitna 3105, Czech Republic. Electronic address: slavka.viteckova@fbmi.cvut.cz.
245    10
$a Extended Timed Up & Go test: Is walking forward and returning back to the chair equivalent gait? / $c S. Viteckova, V. Cejka, P. Dusek, R. Krupicka, P. Kutilek, Z. Szabo, E. Růžička,
520    9_
$a The Timed Up & Go test (TUG) is functional test and is a part of routine clinical examinations. The instrumented Timed Up & Go test enables its segmentation to sub-tasks: sit-to-stand, walking forward, turning, walking back, stand-to-sit, and consequently the computation of task-specific parameters and sub-tasks separately. However, there are no data on whether walking forward parameters differ from the walking back parameters. This study tested the differences between walking forward and walking back in the TUG extended to 10 m for 17 spatio-temporal gait parameters. All parameters were obtained from a GAITRite® pressure sensitive walkway (CIR Systems, Inc.). The differences were assessed for healthy controls and Parkinson's disease (PD) patients. None of investigated parameters exhibited a difference between both gait subtasks for healthy subjects group. Five parameters of interest, namely velocity, step length, stride length, stride velocity, and the proportion of the double support phase with respect to gait cycle duration, showed a statistically significant difference between gait for walking forward and walking back in PD patients. Therefore, we recommend a separate assessment for walking forward and walking back rather than averaging both gaits together.
650    _2
$a senioři $7 D000368
650    _2
$a studie případů a kontrol $7 D016022
650    _2
$a ženské pohlaví $7 D005260
650    _2
$a analýza chůze $x metody $7 D000077107
650    _2
$a lidé $7 D006801
650    _2
$a mužské pohlaví $7 D008297
650    _2
$a lidé středního věku $7 D008875
650    _2
$a Parkinsonova nemoc $x patofyziologie $7 D010300
650    _2
$a časoprostorová analýza $7 D062211
650    _2
$a časové faktory $7 D013997
650    _2
$a chůze $x fyziologie $7 D016138
655    _2
$a časopisecké články $7 D016428
700    1_
$a Cejka, Vaclav $u Faculty of Biomedical Engineering, Czech Technical University in Prague, nam Sitna 3105, Czech Republic. Electronic address: vaclav.cejka@fbmi.cvut.cz.
700    1_
$a Dusek, Petr $u Department of Neurology and Centre of Clinical Neuroscience, First Faculty of Medicine, Charles University and General University Hospital in Prague, Prague, Czech Republic. Electronic address: petr.dusek@vfn.cz.
700    1_
$a Krupicka, Radim $u Faculty of Biomedical Engineering, Czech Technical University in Prague, nam Sitna 3105, Czech Republic. Electronic address: krupicka@fbmi.cvut.cz.
700    1_
$a Kutilek, Patrik $u Faculty of Biomedical Engineering, Czech Technical University in Prague, nam Sitna 3105, Czech Republic. Electronic address: kutilek@fbmi.cvut.cz.
700    1_
$a Szabo, Zoltan $u Faculty of Biomedical Engineering, Czech Technical University in Prague, nam Sitna 3105, Czech Republic. Electronic address: szabo@fbmi.cvut.cz.
700    1_
$a Růžička, Evžen $u Department of Neurology and Centre of Clinical Neuroscience, First Faculty of Medicine, Charles University and General University Hospital in Prague, Prague, Czech Republic. Electronic address: eruzi@lf1.cuni.cz.
773    0_
$w MED00002553 $t Journal of biomechanics $x 1873-2380 $g Roč. 89, č. - (2019), s. 110-114
856    41
$u https://pubmed.ncbi.nlm.nih.gov/30982536 $y Pubmed
910    __
$a ABA008 $b sig $c sign $y a $z 0
990    __
$a 20201125 $b ABA008
991    __
$a 20201222155502 $b ABA008
999    __
$a ok $b bmc $g 1599993 $s 1116534
BAS    __
$a 3
BAS    __
$a PreBMC
BMC    __
$a 2019 $b 89 $c - $d 110-114 $e 20190410 $i 1873-2380 $m Journal of biomechanics $n J Biomech $x MED00002553
GRA    __
$a NV16-28119A $p MZ0
LZP    __
$a Pubmed-20201125

Find record

Citation metrics

Loading data ...

Archiving options

Loading data ...