Comparison of atrial fibrillation ablation efficacy using remote magnetic navigation vs. manual navigation with contact-force control

J. Jez, T. Jadczyk, F. Lehar, M. Pesl, T. Kulik, S. Belaskova, F. Soucek, G. Caluori, W. Wojakowski, Z. Starek

. 2020 ; 164 (4) : 387-393. [pub] 20191010

Jazyk angličtina Země Česko

Typ dokumentu srovnávací studie, časopisecké články

Perzistentní odkaz   https://www.medvik.cz/link/bmc21023713

AIMS: This study aims to compare procedural parameters and clinical efficacy of remote magnetic navigation (RMN) vs. manual navigation (MAN) approach for radiofrequency ablation (RFA) in patients with atrial fibrillation (AF). METHODS: 146 patients with AF were enrolled in the study. In the RMN group (n=57), patients were treated with the CARTO® 3 in combination with the Niobe ES system. In the MAN group (n=89), ablation was performed with the EnSite Velocity and TactiCath™ Quartz catheter with direct contact force measurement. Procedural time, ablation time, fluoroscopy time, radiation dose and ablation counts were measured and compared between the groups. Recurrence of AF was evaluated after 6 months of follow-up. RESULTS: Mean procedure times (236.87±64.31 vs. 147.22±45.19 min, P<0.05), counts of RF applications (74.30±24.77 vs. 49.15±20.33, P<0.05) and total RFA times (4323.39±1426.69 vs. 2780.53±1157.85 s, P<0.05) were all significantly higher in the RMN than in the MAN group, respectively. In the same order, mean X-ray dose (9722.6±7507.4 vs. 8087.9±6051.5 mGy/cm2, P=0.12) and mean total X-ray exposure time (8.07±4.20 vs. 9.54±5.47 min, P=0.08) were not statistically different. At 6-month follow-up, freedom from AF was similar in RMN and MAN group for paroxysmal (60.8% and 73%, respectively, P=0.42) and persistent AF (69.6% and 75.0%, respectively, P=0.77). CONCLUSIONS: Due to the fact that mid-term clinical outcomes showed no significant differences in AF recurrences between groups and manual ablation strategy provided more favorable results regarding acute procedural parameters, we can conclude that the remote magnetic navigation is not superior to the manual approach.

Citace poskytuje Crossref.org

Bibliografie atd.

Literatura

000      
00000naa a2200000 a 4500
001      
bmc21023713
003      
CZ-PrNML
005      
20211104134118.0
007      
ta
008      
211005s2020 xr a f 000 0|eng||
009      
AR
024    7_
$a 10.5507/bp.2019.045 $2 doi
035    __
$a (PubMed)31645769
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a xr
100    1_
$a Jež, Ondřej $7 mzk2008486367 $u International Clinical Research Center, Interventional Cardiac Electrophysiology, St. Anne's University Hospital Brno, Czech Republic $u Department of Cardiovascular Diseases, Faculty of Medicine, Masaryk University, Brno, Czech Republic
245    10
$a Comparison of atrial fibrillation ablation efficacy using remote magnetic navigation vs. manual navigation with contact-force control / $c J. Jez, T. Jadczyk, F. Lehar, M. Pesl, T. Kulik, S. Belaskova, F. Soucek, G. Caluori, W. Wojakowski, Z. Starek
504    __
$a Literatura
520    9_
$a AIMS: This study aims to compare procedural parameters and clinical efficacy of remote magnetic navigation (RMN) vs. manual navigation (MAN) approach for radiofrequency ablation (RFA) in patients with atrial fibrillation (AF). METHODS: 146 patients with AF were enrolled in the study. In the RMN group (n=57), patients were treated with the CARTO® 3 in combination with the Niobe ES system. In the MAN group (n=89), ablation was performed with the EnSite Velocity and TactiCath™ Quartz catheter with direct contact force measurement. Procedural time, ablation time, fluoroscopy time, radiation dose and ablation counts were measured and compared between the groups. Recurrence of AF was evaluated after 6 months of follow-up. RESULTS: Mean procedure times (236.87±64.31 vs. 147.22±45.19 min, P<0.05), counts of RF applications (74.30±24.77 vs. 49.15±20.33, P<0.05) and total RFA times (4323.39±1426.69 vs. 2780.53±1157.85 s, P<0.05) were all significantly higher in the RMN than in the MAN group, respectively. In the same order, mean X-ray dose (9722.6±7507.4 vs. 8087.9±6051.5 mGy/cm2, P=0.12) and mean total X-ray exposure time (8.07±4.20 vs. 9.54±5.47 min, P=0.08) were not statistically different. At 6-month follow-up, freedom from AF was similar in RMN and MAN group for paroxysmal (60.8% and 73%, respectively, P=0.42) and persistent AF (69.6% and 75.0%, respectively, P=0.77). CONCLUSIONS: Due to the fact that mid-term clinical outcomes showed no significant differences in AF recurrences between groups and manual ablation strategy provided more favorable results regarding acute procedural parameters, we can conclude that the remote magnetic navigation is not superior to the manual approach.
650    _2
$a senioři $7 D000368
650    _2
$a senioři nad 80 let $7 D000369
650    _2
$a fibrilace síní $x chirurgie $7 D001281
650    _2
$a elektrofyziologické techniky kardiologické $x metody $x statistika a číselné údaje $7 D022062
650    _2
$a ženské pohlaví $7 D005260
650    _2
$a lidé $7 D006801
650    _2
$a mužské pohlaví $7 D008297
650    _2
$a lidé středního věku $7 D008875
650    _2
$a radiofrekvenční ablace $x metody $x statistika a číselné údaje $7 D000078703
650    _2
$a retrospektivní studie $7 D012189
650    _2
$a chirurgické navigační systémy $x statistika a číselné údaje $7 D000085022
650    12
$a výsledek terapie $7 D016896
655    _2
$a srovnávací studie $7 D003160
655    _2
$a časopisecké články $7 D016428
700    1_
$a Jadczyk, Tomasz $7 _AN111846 $u International Clinical Research Center, Interventional Cardiac Electrophysiology, St. Anne's University Hospital Brno, Czech Republic $u Department of Cardiology and Structural Heart Diseases, Medical University of Silesia, Katowice, Poland
700    1_
$a Lehár, František $7 _AN050454 $u International Clinical Research Center, Interventional Cardiac Electrophysiology, St. Anne's University Hospital Brno, Czech Republic $u Department of Cardiovascular Diseases, Faculty of Medicine, Masaryk University, Brno, Czech Republic
700    1_
$a Pešl, Martin $7 xx0143722 $u International Clinical Research Center, Interventional Cardiac Electrophysiology, St. Anne's University Hospital Brno, Czech Republic $u Department of Cardiovascular Diseases, Faculty of Medicine, Masaryk University, Brno, Czech Republic $u Department of Biology, Faculty of Medicine, Masaryk University, Brno, Czech Republic
700    1_
$a Kulík, Tomáš $7 xx0265331 $u International Clinical Research Center, Interventional Cardiac Electrophysiology, St. Anne's University Hospital Brno, Czech Republic
700    1_
$a Bělašková, Silvie $7 utb2012711571 $u Biostatistics, International Clinical Research Center, St. Anne's University Hospital Brno, Brno, Czech Republic
700    1_
$a Souček, Filip, $d 1984- $7 xx0227657 $u International Clinical Research Center, Interventional Cardiac Electrophysiology, St. Anne's University Hospital Brno, Czech Republic
700    1_
$a Caluori, Guido $7 _AN111847 $u International Clinical Research Center, Interventional Cardiac Electrophysiology, St. Anne's University Hospital Brno, Czech Republic $u CEITEC, Masaryk University, Brno, Czech Republic
700    1_
$a Wojakowski, Wojciech $u Department of Cardiology and Structural Heart Diseases, Medical University of Silesia, Katowice, Poland
700    1_
$a Stárek, Zdeněk $7 xx0041320 $u International Clinical Research Center, Interventional Cardiac Electrophysiology, St. Anne's University Hospital Brno, Czech Republic $u Department of Cardiovascular Diseases, Faculty of Medicine, Masaryk University, Brno, Czech Republic
773    0_
$w MED00012606 $t Biomedical papers of the Medical Faculty of the University Palacky, Olomouc, Czechoslovakia $x 1213-8118 $g Roč. 164, č. 4 (2020), s. 387-393
856    41
$u https://pubmed.ncbi.nlm.nih.gov/31645769 $y Pubmed
910    __
$a ABA008 $b A 1502 $c 958 $y p $z 0
990    __
$a 20211005 $b ABA008
991    __
$a 20211007151458 $b ABA008
999    __
$a ok $b bmc $g 1718901 $s 1144207
BAS    __
$a 3
BAS    __
$a PreBMC
BMC    __
$a 2020 $b 164 $c 4 $d 387-393 $e 20191010 $i 1213-8118 $m Biomedical papers of the Medical Faculty of the University Palacký, Olomouc Czech Republic $n Biomed. Pap. Fac. Med. Palacký Univ. Olomouc Czech Repub. (Print) $x MED00012606
LZP    __
$b NLK118 $a Pubmed-20211005

Najít záznam

Citační ukazatele

Pouze přihlášení uživatelé

Možnosti archivace

Nahrávání dat ...