Comparison of atrial fibrillation ablation efficacy using remote magnetic navigation vs. manual navigation with contact-force control
J. Jez, T. Jadczyk, F. Lehar, M. Pesl, T. Kulik, S. Belaskova, F. Soucek, G. Caluori, W. Wojakowski, Z. Starek
Jazyk angličtina Země Česko
Typ dokumentu srovnávací studie, časopisecké články
NLK
Directory of Open Access Journals
od 2001
Free Medical Journals
od 1998
Medline Complete (EBSCOhost)
od 2007-06-01
ROAD: Directory of Open Access Scholarly Resources
od 2001
PubMed
31645769
DOI
10.5507/bp.2019.045
Knihovny.cz E-zdroje
- MeSH
- chirurgické navigační systémy statistika a číselné údaje MeSH
- elektrofyziologické techniky kardiologické metody statistika a číselné údaje MeSH
- fibrilace síní chirurgie MeSH
- lidé středního věku MeSH
- lidé MeSH
- radiofrekvenční ablace metody statistika a číselné údaje MeSH
- retrospektivní studie MeSH
- senioři nad 80 let MeSH
- senioři MeSH
- výsledek terapie * MeSH
- Check Tag
- lidé středního věku MeSH
- lidé MeSH
- mužské pohlaví MeSH
- senioři nad 80 let MeSH
- senioři MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- srovnávací studie MeSH
AIMS: This study aims to compare procedural parameters and clinical efficacy of remote magnetic navigation (RMN) vs. manual navigation (MAN) approach for radiofrequency ablation (RFA) in patients with atrial fibrillation (AF). METHODS: 146 patients with AF were enrolled in the study. In the RMN group (n=57), patients were treated with the CARTO® 3 in combination with the Niobe ES system. In the MAN group (n=89), ablation was performed with the EnSite Velocity and TactiCath™ Quartz catheter with direct contact force measurement. Procedural time, ablation time, fluoroscopy time, radiation dose and ablation counts were measured and compared between the groups. Recurrence of AF was evaluated after 6 months of follow-up. RESULTS: Mean procedure times (236.87±64.31 vs. 147.22±45.19 min, P<0.05), counts of RF applications (74.30±24.77 vs. 49.15±20.33, P<0.05) and total RFA times (4323.39±1426.69 vs. 2780.53±1157.85 s, P<0.05) were all significantly higher in the RMN than in the MAN group, respectively. In the same order, mean X-ray dose (9722.6±7507.4 vs. 8087.9±6051.5 mGy/cm2, P=0.12) and mean total X-ray exposure time (8.07±4.20 vs. 9.54±5.47 min, P=0.08) were not statistically different. At 6-month follow-up, freedom from AF was similar in RMN and MAN group for paroxysmal (60.8% and 73%, respectively, P=0.42) and persistent AF (69.6% and 75.0%, respectively, P=0.77). CONCLUSIONS: Due to the fact that mid-term clinical outcomes showed no significant differences in AF recurrences between groups and manual ablation strategy provided more favorable results regarding acute procedural parameters, we can conclude that the remote magnetic navigation is not superior to the manual approach.
CEITEC Masaryk University Brno Czech Republic
Department of Biology Faculty of Medicine Masaryk University Brno Czech Republic
Department of Cardiology and Structural Heart Diseases Medical University of Silesia Katowice Poland
Department of Cardiovascular Diseases Faculty of Medicine Masaryk University Brno Czech Republic
Citace poskytuje Crossref.org
Literatura
- 000
- 00000naa a2200000 a 4500
- 001
- bmc21023713
- 003
- CZ-PrNML
- 005
- 20211104134118.0
- 007
- ta
- 008
- 211005s2020 xr a f 000 0|eng||
- 009
- AR
- 024 7_
- $a 10.5507/bp.2019.045 $2 doi
- 035 __
- $a (PubMed)31645769
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a xr
- 100 1_
- $a Jež, Ondřej $7 mzk2008486367 $u International Clinical Research Center, Interventional Cardiac Electrophysiology, St. Anne's University Hospital Brno, Czech Republic $u Department of Cardiovascular Diseases, Faculty of Medicine, Masaryk University, Brno, Czech Republic
- 245 10
- $a Comparison of atrial fibrillation ablation efficacy using remote magnetic navigation vs. manual navigation with contact-force control / $c J. Jez, T. Jadczyk, F. Lehar, M. Pesl, T. Kulik, S. Belaskova, F. Soucek, G. Caluori, W. Wojakowski, Z. Starek
- 504 __
- $a Literatura
- 520 9_
- $a AIMS: This study aims to compare procedural parameters and clinical efficacy of remote magnetic navigation (RMN) vs. manual navigation (MAN) approach for radiofrequency ablation (RFA) in patients with atrial fibrillation (AF). METHODS: 146 patients with AF were enrolled in the study. In the RMN group (n=57), patients were treated with the CARTO® 3 in combination with the Niobe ES system. In the MAN group (n=89), ablation was performed with the EnSite Velocity and TactiCath™ Quartz catheter with direct contact force measurement. Procedural time, ablation time, fluoroscopy time, radiation dose and ablation counts were measured and compared between the groups. Recurrence of AF was evaluated after 6 months of follow-up. RESULTS: Mean procedure times (236.87±64.31 vs. 147.22±45.19 min, P<0.05), counts of RF applications (74.30±24.77 vs. 49.15±20.33, P<0.05) and total RFA times (4323.39±1426.69 vs. 2780.53±1157.85 s, P<0.05) were all significantly higher in the RMN than in the MAN group, respectively. In the same order, mean X-ray dose (9722.6±7507.4 vs. 8087.9±6051.5 mGy/cm2, P=0.12) and mean total X-ray exposure time (8.07±4.20 vs. 9.54±5.47 min, P=0.08) were not statistically different. At 6-month follow-up, freedom from AF was similar in RMN and MAN group for paroxysmal (60.8% and 73%, respectively, P=0.42) and persistent AF (69.6% and 75.0%, respectively, P=0.77). CONCLUSIONS: Due to the fact that mid-term clinical outcomes showed no significant differences in AF recurrences between groups and manual ablation strategy provided more favorable results regarding acute procedural parameters, we can conclude that the remote magnetic navigation is not superior to the manual approach.
- 650 _2
- $a senioři $7 D000368
- 650 _2
- $a senioři nad 80 let $7 D000369
- 650 _2
- $a fibrilace síní $x chirurgie $7 D001281
- 650 _2
- $a elektrofyziologické techniky kardiologické $x metody $x statistika a číselné údaje $7 D022062
- 650 _2
- $a ženské pohlaví $7 D005260
- 650 _2
- $a lidé $7 D006801
- 650 _2
- $a mužské pohlaví $7 D008297
- 650 _2
- $a lidé středního věku $7 D008875
- 650 _2
- $a radiofrekvenční ablace $x metody $x statistika a číselné údaje $7 D000078703
- 650 _2
- $a retrospektivní studie $7 D012189
- 650 _2
- $a chirurgické navigační systémy $x statistika a číselné údaje $7 D000085022
- 650 12
- $a výsledek terapie $7 D016896
- 655 _2
- $a srovnávací studie $7 D003160
- 655 _2
- $a časopisecké články $7 D016428
- 700 1_
- $a Jadczyk, Tomasz $7 _AN111846 $u International Clinical Research Center, Interventional Cardiac Electrophysiology, St. Anne's University Hospital Brno, Czech Republic $u Department of Cardiology and Structural Heart Diseases, Medical University of Silesia, Katowice, Poland
- 700 1_
- $a Lehár, František $7 _AN050454 $u International Clinical Research Center, Interventional Cardiac Electrophysiology, St. Anne's University Hospital Brno, Czech Republic $u Department of Cardiovascular Diseases, Faculty of Medicine, Masaryk University, Brno, Czech Republic
- 700 1_
- $a Pešl, Martin $7 xx0143722 $u International Clinical Research Center, Interventional Cardiac Electrophysiology, St. Anne's University Hospital Brno, Czech Republic $u Department of Cardiovascular Diseases, Faculty of Medicine, Masaryk University, Brno, Czech Republic $u Department of Biology, Faculty of Medicine, Masaryk University, Brno, Czech Republic
- 700 1_
- $a Kulík, Tomáš $7 xx0265331 $u International Clinical Research Center, Interventional Cardiac Electrophysiology, St. Anne's University Hospital Brno, Czech Republic
- 700 1_
- $a Bělašková, Silvie $7 utb2012711571 $u Biostatistics, International Clinical Research Center, St. Anne's University Hospital Brno, Brno, Czech Republic
- 700 1_
- $a Souček, Filip, $d 1984- $7 xx0227657 $u International Clinical Research Center, Interventional Cardiac Electrophysiology, St. Anne's University Hospital Brno, Czech Republic
- 700 1_
- $a Caluori, Guido $7 _AN111847 $u International Clinical Research Center, Interventional Cardiac Electrophysiology, St. Anne's University Hospital Brno, Czech Republic $u CEITEC, Masaryk University, Brno, Czech Republic
- 700 1_
- $a Wojakowski, Wojciech $u Department of Cardiology and Structural Heart Diseases, Medical University of Silesia, Katowice, Poland
- 700 1_
- $a Stárek, Zdeněk $7 xx0041320 $u International Clinical Research Center, Interventional Cardiac Electrophysiology, St. Anne's University Hospital Brno, Czech Republic $u Department of Cardiovascular Diseases, Faculty of Medicine, Masaryk University, Brno, Czech Republic
- 773 0_
- $w MED00012606 $t Biomedical papers of the Medical Faculty of the University Palacky, Olomouc, Czechoslovakia $x 1213-8118 $g Roč. 164, č. 4 (2020), s. 387-393
- 856 41
- $u https://pubmed.ncbi.nlm.nih.gov/31645769 $y Pubmed
- 910 __
- $a ABA008 $b A 1502 $c 958 $y p $z 0
- 990 __
- $a 20211005 $b ABA008
- 991 __
- $a 20211007151458 $b ABA008
- 999 __
- $a ok $b bmc $g 1718901 $s 1144207
- BAS __
- $a 3
- BAS __
- $a PreBMC
- BMC __
- $a 2020 $b 164 $c 4 $d 387-393 $e 20191010 $i 1213-8118 $m Biomedical papers of the Medical Faculty of the University Palacký, Olomouc Czech Republic $n Biomed. Pap. Fac. Med. Palacký Univ. Olomouc Czech Repub. (Print) $x MED00012606
- LZP __
- $b NLK118 $a Pubmed-20211005