• Je něco špatně v tomto záznamu ?

At-line coupling of hollow fiber liquid-phase microextraction to capillary electrophoresis for trace determination of acidic drugs in complex samples

B. Miková, M. Dvořák, L. Ryšavá, Z. Malá, P. Gebauer, P. Kubáň

. 2022 ; 238 (Pt 2) : 123068. [pub] 20211115

Jazyk angličtina Země Nizozemsko

Typ dokumentu časopisecké články

Perzistentní odkaz   https://www.medvik.cz/link/bmc22002959

Direct analysis of complex samples is demonstrated by the at-line coupling of hollow fiber liquid-phase microextraction (HF-LPME) to capillary electrophoresis (CE). The hyphenation of the preparative and the analytical technique is achieved through a 3D-printed microextraction device with an HF located in a sample vial of a commercial CE instrument. The internal geometry of the device guides the CE separation capillary into the HF and the CE injection of the HF-LPME extract is performed directly from the HF lumen. The 3D-printing process ensures uniform dimensions of the devices, their constant position inside the sample vial, and excellent repeatability of the HF-LPME as well as the CE injection. The devices are cheap (∼0.01 €) and disposable, thus eliminating any possible sample-carryover, moreover, the at-line CE analysis of the extract is performed fully autonomously with no need for operator's intervention. The developed HF-LPME/CE-UV method is applied to the determination of acidic drugs in dried blood spot and wastewater samples and is characterized by excellent repeatability (RSD, 0.6-9.6%), linearity (r2, 0.9991-0.9999), enrichment (EF, 29-97), sensitivity (LOD, 0.2-3.4 μg/L), and sample throughput (7 samples/h). A further improvement of selected characteristics of the analytical method is achieved by the at-line coupling of HF-LPME to capillary isotachophoresis (ITP) with electrospray ionization-mass spectrometry (ESI-MS). The HF-LPME/ITP-ESI-MS system facilitates enhanced selectivity, matrix-free analytical signals, and up to 34-fold better sensitivity due to the use of ESI-MS detection and additional on-capillary ITP preconcentration of the HF-LPME extracts.

Citace poskytuje Crossref.org

000      
00000naa a2200000 a 4500
001      
bmc22002959
003      
CZ-PrNML
005      
20220127150753.0
007      
ta
008      
220113s2022 ne f 000 0|eng||
009      
AR
024    7_
$a 10.1016/j.talanta.2021.123068 $2 doi
035    __
$a (PubMed)34808568
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a ne
100    1_
$a Miková, Blanka $u Institute of Analytical Chemistry of the Czech Academy of Sciences, Veveří 97, CZ-60200, Brno, Czech Republic; Department of Analytical Chemistry, Masaryk University, Kotlářská 2, CZ-60200, Brno, Czech Republic
245    10
$a At-line coupling of hollow fiber liquid-phase microextraction to capillary electrophoresis for trace determination of acidic drugs in complex samples / $c B. Miková, M. Dvořák, L. Ryšavá, Z. Malá, P. Gebauer, P. Kubáň
520    9_
$a Direct analysis of complex samples is demonstrated by the at-line coupling of hollow fiber liquid-phase microextraction (HF-LPME) to capillary electrophoresis (CE). The hyphenation of the preparative and the analytical technique is achieved through a 3D-printed microextraction device with an HF located in a sample vial of a commercial CE instrument. The internal geometry of the device guides the CE separation capillary into the HF and the CE injection of the HF-LPME extract is performed directly from the HF lumen. The 3D-printing process ensures uniform dimensions of the devices, their constant position inside the sample vial, and excellent repeatability of the HF-LPME as well as the CE injection. The devices are cheap (∼0.01 €) and disposable, thus eliminating any possible sample-carryover, moreover, the at-line CE analysis of the extract is performed fully autonomously with no need for operator's intervention. The developed HF-LPME/CE-UV method is applied to the determination of acidic drugs in dried blood spot and wastewater samples and is characterized by excellent repeatability (RSD, 0.6-9.6%), linearity (r2, 0.9991-0.9999), enrichment (EF, 29-97), sensitivity (LOD, 0.2-3.4 μg/L), and sample throughput (7 samples/h). A further improvement of selected characteristics of the analytical method is achieved by the at-line coupling of HF-LPME to capillary isotachophoresis (ITP) with electrospray ionization-mass spectrometry (ESI-MS). The HF-LPME/ITP-ESI-MS system facilitates enhanced selectivity, matrix-free analytical signals, and up to 34-fold better sensitivity due to the use of ESI-MS detection and additional on-capillary ITP preconcentration of the HF-LPME extracts.
650    _2
$a elektroforéza kapilární $7 D019075
650    12
$a izotachoforéza $7 D057625
650    12
$a mikroextrakce kapalné fáze $7 D059627
650    12
$a léčivé přípravky $7 D004364
650    _2
$a hmotnostní spektrometrie s elektrosprejovou ionizací $7 D021241
655    _2
$a časopisecké články $7 D016428
700    1_
$a Dvořák, Miloš $u Institute of Analytical Chemistry of the Czech Academy of Sciences, Veveří 97, CZ-60200, Brno, Czech Republic
700    1_
$a Ryšavá, Lenka $u Institute of Analytical Chemistry of the Czech Academy of Sciences, Veveří 97, CZ-60200, Brno, Czech Republic; Institute of Food Science and Biotechnology, Faculty of Chemistry, Brno University of Technology, Purkyňova 118, CZ-61200, Brno, Czech Republic
700    1_
$a Malá, Zdenka $u Institute of Analytical Chemistry of the Czech Academy of Sciences, Veveří 97, CZ-60200, Brno, Czech Republic
700    1_
$a Gebauer, Petr $u Institute of Analytical Chemistry of the Czech Academy of Sciences, Veveří 97, CZ-60200, Brno, Czech Republic
700    1_
$a Kubáň, Pavel $u Institute of Analytical Chemistry of the Czech Academy of Sciences, Veveří 97, CZ-60200, Brno, Czech Republic. Electronic address: kuban@iach.cz
773    0_
$w MED00004484 $t Talanta $x 1873-3573 $g Roč. 238, č. Pt 2 (2022), s. 123068
856    41
$u https://pubmed.ncbi.nlm.nih.gov/34808568 $y Pubmed
910    __
$a ABA008 $b sig $c sign $y p $z 0
990    __
$a 20220113 $b ABA008
991    __
$a 20220127150749 $b ABA008
999    __
$a ok $b bmc $g 1750679 $s 1154108
BAS    __
$a 3
BAS    __
$a PreBMC
BMC    __
$a 2022 $b 238 $c Pt 2 $d 123068 $e 20211115 $i 1873-3573 $m Talanta $n Talanta $x MED00004484
LZP    __
$a Pubmed-20220113

Najít záznam

Citační ukazatele

Nahrávání dat ...

Možnosti archivace

Nahrávání dat ...