Electromechanical factors associated with favourable outcome in cardiac resynchronization therapy

F. Maffessanti, T. Jadczyk, J. Wilczek, G. Conte, ML. Caputo, KS. Gołba, J. Biernat, M. Cybulska, G. Caluori, F. Regoli, R. Krause, W. Wojakowski, FW. Prinzen, A. Auricchio

. 2023 ; 25 (2) : 546-553. [pub] 2023Feb16

Language English Country England, Great Britain

Document type Journal Article

Grant support
32003B_165802 Swiss National Science Foundation - Switzerland

AIMS: Electromechanical coupling in patients receiving cardiac resynchronization therapy (CRT) is not fully understood. Our aim was to determine the best combination of electrical and mechanical substrates associated with effective CRT. METHODS AND RESULTS: Sixty-two patients were prospectively enrolled from two centres. Patients underwent 12-lead electrocardiogram (ECG), cardiovascular magnetic resonance (CMR), echocardiography, and anatomo-electromechanical mapping (AEMM). Remodelling was measured as the end-systolic volume (ΔESV) decrease at 6 months. CRT was defined effective with ΔESV ≤ -15%. QRS duration (QRSd) was measured from ECG. Area strain was obtained from AEMM and used to derive systolic stretch index (SSI) and total left-ventricular mechanical time. Total left-ventricular activation time (TLVAT) and transeptal time (TST) were derived from AEMM and ECG. Scar was measured from CMR. Significant correlations were observed between ΔESV and TST [rho = 0.42; responder: 50 (20-58) vs. non-responder: 33 (8-44) ms], TLVAT [-0.68; 81 (73-97) vs. 112 (96-127) ms], scar [-0.27; 0.0 (0.0-1.2) vs. 8.7 (0.0-19.1)%], and SSI [0.41; 10.7 (7.1-16.8) vs. 4.2 (2.9-5.5)], but not QRSd [-0.13; 155 (140-176) vs. 167 (155-177) ms]. TLVAT and SSI were highly accurate in identifying CRT response [area under the curve (AUC) > 0.80], followed by scar (AUC > 0.70). Total left-ventricular activation time (odds ratio = 0.91), scar (0.94), and SSI (1.29) were independent factors associated with effective CRT. Subjects with SSI >7.9% and TLVAT <91 ms all responded to CRT with a median ΔESV ≈ -50%, while low SSI and prolonged TLVAT were more common in non-responders (ΔESV ≈ -5%). CONCLUSION: Electromechanical measurements are better associated with CRT response than conventional ECG variables. The absence of scar combined with high SSI and low TLVAT ensures effectiveness of CRT.

References provided by Crossref.org

000      
00000naa a2200000 a 4500
001      
bmc23004158
003      
CZ-PrNML
005      
20230425141129.0
007      
ta
008      
230418s2023 enk f 000 0|eng||
009      
AR
024    7_
$a 10.1093/europace/euac157 $2 doi
035    __
$a (PubMed)36106562
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a enk
100    1_
$a Maffessanti, Francesco $u Center for Computational Medicine in Cardiology, Università della Svizzera Italiana, Lugano, Switzerland $u Maria Cecilia Hospital, GVM Care and Research, Cotignola, Italy $1 https://orcid.org/0000000173643734
245    10
$a Electromechanical factors associated with favourable outcome in cardiac resynchronization therapy / $c F. Maffessanti, T. Jadczyk, J. Wilczek, G. Conte, ML. Caputo, KS. Gołba, J. Biernat, M. Cybulska, G. Caluori, F. Regoli, R. Krause, W. Wojakowski, FW. Prinzen, A. Auricchio
520    9_
$a AIMS: Electromechanical coupling in patients receiving cardiac resynchronization therapy (CRT) is not fully understood. Our aim was to determine the best combination of electrical and mechanical substrates associated with effective CRT. METHODS AND RESULTS: Sixty-two patients were prospectively enrolled from two centres. Patients underwent 12-lead electrocardiogram (ECG), cardiovascular magnetic resonance (CMR), echocardiography, and anatomo-electromechanical mapping (AEMM). Remodelling was measured as the end-systolic volume (ΔESV) decrease at 6 months. CRT was defined effective with ΔESV ≤ -15%. QRS duration (QRSd) was measured from ECG. Area strain was obtained from AEMM and used to derive systolic stretch index (SSI) and total left-ventricular mechanical time. Total left-ventricular activation time (TLVAT) and transeptal time (TST) were derived from AEMM and ECG. Scar was measured from CMR. Significant correlations were observed between ΔESV and TST [rho = 0.42; responder: 50 (20-58) vs. non-responder: 33 (8-44) ms], TLVAT [-0.68; 81 (73-97) vs. 112 (96-127) ms], scar [-0.27; 0.0 (0.0-1.2) vs. 8.7 (0.0-19.1)%], and SSI [0.41; 10.7 (7.1-16.8) vs. 4.2 (2.9-5.5)], but not QRSd [-0.13; 155 (140-176) vs. 167 (155-177) ms]. TLVAT and SSI were highly accurate in identifying CRT response [area under the curve (AUC) > 0.80], followed by scar (AUC > 0.70). Total left-ventricular activation time (odds ratio = 0.91), scar (0.94), and SSI (1.29) were independent factors associated with effective CRT. Subjects with SSI >7.9% and TLVAT <91 ms all responded to CRT with a median ΔESV ≈ -50%, while low SSI and prolonged TLVAT were more common in non-responders (ΔESV ≈ -5%). CONCLUSION: Electromechanical measurements are better associated with CRT response than conventional ECG variables. The absence of scar combined with high SSI and low TLVAT ensures effectiveness of CRT.
650    _2
$a lidé $7 D006801
650    12
$a srdeční resynchronizační terapie $x škodlivé účinky $x metody $7 D058406
650    _2
$a funkce levé komory srdeční $x fyziologie $7 D016277
650    _2
$a jizva $7 D002921
650    _2
$a blokáda Tawarova raménka $7 D002037
650    _2
$a echokardiografie $7 D004452
650    _2
$a elektrokardiografie $x metody $7 D004562
650    _2
$a výsledek terapie $7 D016896
650    12
$a srdeční selhání $x diagnóza $x terapie $7 D006333
655    _2
$a časopisecké články $7 D016428
700    1_
$a Jadczyk, Tomasz $u Division of Cardiology and Structural Heart Diseases, Medical University of Silesia, Katowice, Poland $u Interventional Cardiac Electrophysiology Group, International Clinical Research Center, St. Anne's University Hospital Brno, Brno, Czech Republic $1 https://orcid.org/0000000279559100
700    1_
$a Wilczek, Jacek $u Department of Electrocardiology and Heart Failure, Medical University of Silesia, Katowice, Poland $1 https://orcid.org/0000000199452573
700    1_
$a Conte, Giulio $u Division of Cardiology, Istituto Cardiocentro Ticino, Lugano, Switzerland $1 https://orcid.org/0000000322483456
700    1_
$a Caputo, Maria Luce $u Division of Cardiology, Istituto Cardiocentro Ticino, Lugano, Switzerland
700    1_
$a Gołba, Krzysztof S $u Department of Electrocardiology and Heart Failure, Medical University of Silesia, Katowice, Poland $1 https://orcid.org/0000000157227976
700    1_
$a Biernat, Jolanta $u Department of Electrocardiology and Heart Failure, Medical University of Silesia, Katowice, Poland $1 https://orcid.org/0000000243969001
700    1_
$a Cybulska, Magdalena $u Department of Electrocardiology and Heart Failure, Medical University of Silesia, Katowice, Poland $1 https://orcid.org/0000000233089991
700    1_
$a Caluori, Guido $u IHU LIRYC, Electrophysiology and Heart Modeling Institute, Fondation Bordeaux Université, University of Bordeaux & INSERM, U 1045,Cardiothoracic Research Center of Bordeaux, Pessac, France $1 https://orcid.org/0000000327258768
700    1_
$a Regoli, François $u Division of Cardiology, Istituto Cardiocentro Ticino, Lugano, Switzerland $u Cardiology Service, Ospedale Regionale di Bellinzona e Valli, Bellinzona, Switzerland $1 https://orcid.org/0000000150032252
700    1_
$a Krause, Rolf $u Center for Computational Medicine in Cardiology, Università della Svizzera Italiana, Lugano, Switzerland $u Euler institute, Università della Svizzera Italiana, Lugano, Switzerland $1 https://orcid.org/0000000154085271
700    1_
$a Wojakowski, Wojciech $u Division of Cardiology and Structural Heart Diseases, Medical University of Silesia, Katowice, Poland $1 https://orcid.org/0000000236815207
700    1_
$a Prinzen, Frits W $u Department of Physiology, CARIM, Maastricht University, Maastricht, The Netherlands $1 https://orcid.org/0000000189179032
700    1_
$a Auricchio, Angelo $u Center for Computational Medicine in Cardiology, Università della Svizzera Italiana, Lugano, Switzerland $u Division of Cardiology, Istituto Cardiocentro Ticino, Lugano, Switzerland $1 https://orcid.org/0000000321166993
773    0_
$w MED00149837 $t Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology $x 1532-2092 $g Roč. 25, č. 2 (2023), s. 546-553
856    41
$u https://pubmed.ncbi.nlm.nih.gov/36106562 $y Pubmed
910    __
$a ABA008 $b sig $c sign $y p $z 0
990    __
$a 20230418 $b ABA008
991    __
$a 20230425141125 $b ABA008
999    __
$a ok $b bmc $g 1924679 $s 1190367
BAS    __
$a 3
BAS    __
$a PreBMC-MEDLINE
BMC    __
$a 2023 $b 25 $c 2 $d 546-553 $e 2023Feb16 $i 1532-2092 $m Europace $n Europace $x MED00149837
GRA    __
$a 32003B_165802 $p Swiss National Science Foundation $2 Switzerland
LZP    __
$a Pubmed-20230418

Find record

Citation metrics

Loading data ...

Archiving options

Loading data ...