Something wrong with this record ?
Beyond timing and step counting in 360° turning-in-place assessment: a scoping review
S. Netukova, L. Horakova, Z. Szabo, R. Krupicka
Language English Country England, Great Britain
Document type Systematic Review, Journal Article, Review
Grant support
LX22NPO5107
Ministerstvo Školství, Mládeže a Tělovýchovy
NU20-04-00327
Ministerstvo Zdravotnictví Ceské Republiky
NLK
BioMedCentral
from 2002-01-12
BioMedCentral Open Access
from 2002
Directory of Open Access Journals
from 2002
Free Medical Journals
from 2002
Freely Accessible Science Journals
from 2002
PubMed Central
from 2002
Europe PubMed Central
from 2002
ProQuest Central
from 2009-01-01
Open Access Digital Library
from 2002-05-01
Open Access Digital Library
from 2002-01-01
Open Access Digital Library
from 2002-01-01
Medline Complete (EBSCOhost)
from 2002-05-14
Health & Medicine (ProQuest)
from 2009-01-01
ROAD: Directory of Open Access Scholarly Resources
from 2002
Springer Nature OA/Free Journals
from 2002-12-01
- MeSH
- Leg MeSH
- Stroke * MeSH
- Gait MeSH
- Middle Aged MeSH
- Humans MeSH
- Parkinson Disease * MeSH
- Movement MeSH
- Aged MeSH
- Check Tag
- Middle Aged MeSH
- Humans MeSH
- Aged MeSH
- Publication type
- Journal Article MeSH
- Review MeSH
- Systematic Review MeSH
BACKGROUND: Turning in place is a challenging motor task and is used as a brief assessment test of lower limb function and dynamic balance. This review aims to examine how research of instrumented analysis of turning in place is implemented. In addition to reporting the studied population, we covered acquisition systems, turn detection methods, quantitative parameters, and how these parameters are computed. METHODS: Following the development of a rigorous search strategy, the Web of Science and Scopus were systematically searched for studies involving the use of turning-in-place. From the selected articles, the study population, types of instruments used, turn detection method, and how the turning-in-place characteristics were calculated. RESULTS: Twenty-one papers met the inclusion criteria. The subject groups involved in the reviewed studies included young, middle-aged, and older adults, stroke, multiple sclerosis and Parkinson's disease patients. Inertial measurement units (16 studies) and motion camera systems (5 studies) were employed for gathering measurement data, force platforms were rarely used (2 studies). Two studies used commercial software for turn detection, six studies referenced previously published algorithms, two studies developed a custom detector, and eight studies did not provide any details about the turn detection method. The most frequently used parameters were mean angular velocity (14 cases, 7 studies), turn duration (13 cases, 13 studies), peak angular velocity (8 cases, 8 studies), jerkiness (6 cases, 5 studies) and freezing-of-gait ratios (5 cases, 5 studies). Angular velocities were derived from sensors placed on the lower back (7 cases, 4 studies), trunk (4 cases, 2 studies), and shank (2 cases, 1 study). The rest (9 cases, 8 studies) did not report sensor placement. Calculation of the freezing-of-gait ratio was based on the acceleration of the lower limbs in all cases. Jerkiness computation employed acceleration in the medio-lateral (4 cases) and antero-posterior (1 case) direction. One study did not reported any details about jerkiness computation. CONCLUSION: This review identified the capabilities of turning-in-place assessment in identifying movement differences between the various subject groups. The results, based on data acquired by inertial measurement units across studies, are comparable. A more in-depth analysis of tests developed for gait, which has been adopted in turning-in-place, is needed to examine their validity and accuracy.
References provided by Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc24007471
- 003
- CZ-PrNML
- 005
- 20240423160006.0
- 007
- ta
- 008
- 240412s2024 enk f 000 0|eng||
- 009
- AR
- 024 7_
- $a 10.1186/s12938-024-01208-0 $2 doi
- 035 __
- $a (PubMed)38297359
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a enk
- 100 1_
- $a Netukova, Slavka $u Faculty of Biomedical Engineering, Department of Biomedical Informatics, Czech Technical University, Nam Sitna 3105, Prague, Czech Republic. slavka.netukova@fbmi.cvut.cz
- 245 10
- $a Beyond timing and step counting in 360° turning-in-place assessment: a scoping review / $c S. Netukova, L. Horakova, Z. Szabo, R. Krupicka
- 520 9_
- $a BACKGROUND: Turning in place is a challenging motor task and is used as a brief assessment test of lower limb function and dynamic balance. This review aims to examine how research of instrumented analysis of turning in place is implemented. In addition to reporting the studied population, we covered acquisition systems, turn detection methods, quantitative parameters, and how these parameters are computed. METHODS: Following the development of a rigorous search strategy, the Web of Science and Scopus were systematically searched for studies involving the use of turning-in-place. From the selected articles, the study population, types of instruments used, turn detection method, and how the turning-in-place characteristics were calculated. RESULTS: Twenty-one papers met the inclusion criteria. The subject groups involved in the reviewed studies included young, middle-aged, and older adults, stroke, multiple sclerosis and Parkinson's disease patients. Inertial measurement units (16 studies) and motion camera systems (5 studies) were employed for gathering measurement data, force platforms were rarely used (2 studies). Two studies used commercial software for turn detection, six studies referenced previously published algorithms, two studies developed a custom detector, and eight studies did not provide any details about the turn detection method. The most frequently used parameters were mean angular velocity (14 cases, 7 studies), turn duration (13 cases, 13 studies), peak angular velocity (8 cases, 8 studies), jerkiness (6 cases, 5 studies) and freezing-of-gait ratios (5 cases, 5 studies). Angular velocities were derived from sensors placed on the lower back (7 cases, 4 studies), trunk (4 cases, 2 studies), and shank (2 cases, 1 study). The rest (9 cases, 8 studies) did not report sensor placement. Calculation of the freezing-of-gait ratio was based on the acceleration of the lower limbs in all cases. Jerkiness computation employed acceleration in the medio-lateral (4 cases) and antero-posterior (1 case) direction. One study did not reported any details about jerkiness computation. CONCLUSION: This review identified the capabilities of turning-in-place assessment in identifying movement differences between the various subject groups. The results, based on data acquired by inertial measurement units across studies, are comparable. A more in-depth analysis of tests developed for gait, which has been adopted in turning-in-place, is needed to examine their validity and accuracy.
- 650 _2
- $a lidé středního věku $7 D008875
- 650 _2
- $a lidé $7 D006801
- 650 _2
- $a senioři $7 D000368
- 650 12
- $a Parkinsonova nemoc $7 D010300
- 650 _2
- $a chůze (způsob) $7 D005684
- 650 _2
- $a pohyb $7 D009068
- 650 _2
- $a bérec $7 D007866
- 650 12
- $a cévní mozková příhoda $7 D020521
- 655 _2
- $a systematický přehled $7 D000078182
- 655 _2
- $a časopisecké články $7 D016428
- 655 _2
- $a přehledy $7 D016454
- 700 1_
- $a Horakova, Lucie $u Faculty of Biomedical Engineering, Department of Biomedical Informatics, Czech Technical University, Nam Sitna 3105, Prague, Czech Republic
- 700 1_
- $a Szabo, Zoltan $u Faculty of Biomedical Engineering, Department of Biomedical Informatics, Czech Technical University, Nam Sitna 3105, Prague, Czech Republic
- 700 1_
- $a Krupicka, Radim $u Faculty of Biomedical Engineering, Department of Biomedical Informatics, Czech Technical University, Nam Sitna 3105, Prague, Czech Republic
- 773 0_
- $w MED00008166 $t Biomedical engineering online $x 1475-925X $g Roč. 23, č. 1 (2024), s. 13
- 856 41
- $u https://pubmed.ncbi.nlm.nih.gov/38297359 $y Pubmed
- 910 __
- $a ABA008 $b sig $c sign $y - $z 0
- 990 __
- $a 20240412 $b ABA008
- 991 __
- $a 20240423160002 $b ABA008
- 999 __
- $a ok $b bmc $g 2081458 $s 1217238
- BAS __
- $a 3
- BAS __
- $a PreBMC-MEDLINE
- BMC __
- $a 2024 $b 23 $c 1 $d 13 $e 20240131 $i 1475-925X $m Biomedical engineering online $n Biomed Eng Online $x MED00008166
- GRA __
- $a LX22NPO5107 $p Ministerstvo Školství, Mládeže a Tělovýchovy
- GRA __
- $a NU20-04-00327 $p Ministerstvo Zdravotnictví Ceské Republiky
- LZP __
- $a Pubmed-20240412