Something wrong with this record ?
Ambulantní monitorování krevního tlaku, kvalita spánku a věrohodnost noční hypertenze
[Ambulatory blood pressure monitoring, sleep quality, and reliability of night hypertension]
Samuel Genzor, Eva Kociánová, Ladislav Stanke, Michal Štýbnar, Jan Mizera, Martin Vykopal
Language Czech Country Czech Republic
- MeSH
- Blood Pressure Monitoring, Ambulatory * methods MeSH
- Hypertension * diagnosis complications MeSH
- Clinical Studies as Topic methods MeSH
- Diabetes Complications MeSH
- Sleep Quality * MeSH
- Humans MeSH
- Sleep Wake Disorders MeSH
- Check Tag
- Humans MeSH
Nocturnal hypertension is a significant risk factor for cardiovascular mortality and morbidity. Its determination requires the use of 24-hour blood pressure monitoring (ABPM). However, the examination results can be less reliable in patients with insomnia, habitual short sleep or other sleep disorders. In these patients, it is possible to detect falsely high values of blood pressure in the night interval. At the same time, the treatment of sleep disorders itself could adjust the nighttime values of blood pressure and thus prevent unreasonably intensive treatment of high blood pressure. The article summarizes current knowledge about the effect of sleep quality on the accuracy of diagnosis using ABMP. At the same time, we present the study "How to diagnose true nocturnal hypertension?", which will analyze this clinical problem.
Noční hypertenze je významným rizikovým faktorem pro mortalitu i morbiditu z kardiovaskulárních příčin. K její diagnostice je potřeba použít 24hodinové měření krevního tlaku (AMTK). Výsledky vyšetření však mohou být zkresleny u pacientů s nespavostí, habituálním krátkým spánkem či jinými poruchami spánku. U těchto pacientů je možné zachytit falešně vysoké hodnoty krevního tlaku v nočním intervalu. Přitom léčba samotných poruch spánku by mohla hodnoty nočního tlaku upravit, a tím zabránit nepřiměřeně intenzivní léčbě vysokého krevního tlaku. Článek shrnuje aktuální poznatky o vlivu kvality spánku na přesnost diagnostiky pomocí AMTK. Současně prezentujeme studii „Jak diagnostikovat pravou noční hypertenzi?“, která bude tento klinický problém analyzovat.
Ambulatory blood pressure monitoring, sleep quality, and reliability of night hypertension
References provided by Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc24011440
- 003
- CZ-PrNML
- 005
- 20241025134913.0
- 007
- ta
- 008
- 240903s2024 xr f 000 0|cze||
- 009
- AR
- 024 7_
- $a 10.33678/cor.2023.087 $2 doi
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a cze $b eng
- 044 __
- $a xr
- 100 1_
- $a Genzor, Samuel $7 xx0219019 $u Klinika plicních nemocí a tuberkulózy, Lékařská fakulta Univerzity Palackého a Fakultní nemocnice Olomouc, Olomouc $u Centrum digitálního zdravotnictví, Lékařská fakulta Univerzity Palackého a Fakultní nemocnice Olomouc, Olomouc $u Národní telemedicínské centrum, Lékařská fakulta Univerzity Palackého a Fakultní nemocnice Olomouc, Olomouc
- 245 10
- $a Ambulantní monitorování krevního tlaku, kvalita spánku a věrohodnost noční hypertenze / $c Samuel Genzor, Eva Kociánová, Ladislav Stanke, Michal Štýbnar, Jan Mizera, Martin Vykopal
- 246 31
- $a Ambulatory blood pressure monitoring, sleep quality, and reliability of night hypertension
- 520 3_
- $a Nocturnal hypertension is a significant risk factor for cardiovascular mortality and morbidity. Its determination requires the use of 24-hour blood pressure monitoring (ABPM). However, the examination results can be less reliable in patients with insomnia, habitual short sleep or other sleep disorders. In these patients, it is possible to detect falsely high values of blood pressure in the night interval. At the same time, the treatment of sleep disorders itself could adjust the nighttime values of blood pressure and thus prevent unreasonably intensive treatment of high blood pressure. The article summarizes current knowledge about the effect of sleep quality on the accuracy of diagnosis using ABMP. At the same time, we present the study "How to diagnose true nocturnal hypertension?", which will analyze this clinical problem.
- 520 9_
- $a Noční hypertenze je významným rizikovým faktorem pro mortalitu i morbiditu z kardiovaskulárních příčin. K její diagnostice je potřeba použít 24hodinové měření krevního tlaku (AMTK). Výsledky vyšetření však mohou být zkresleny u pacientů s nespavostí, habituálním krátkým spánkem či jinými poruchami spánku. U těchto pacientů je možné zachytit falešně vysoké hodnoty krevního tlaku v nočním intervalu. Přitom léčba samotných poruch spánku by mohla hodnoty nočního tlaku upravit, a tím zabránit nepřiměřeně intenzivní léčbě vysokého krevního tlaku. Článek shrnuje aktuální poznatky o vlivu kvality spánku na přesnost diagnostiky pomocí AMTK. Současně prezentujeme studii „Jak diagnostikovat pravou noční hypertenzi?“, která bude tento klinický problém analyzovat.
- 650 07
- $a lidé $7 D006801 $2 czmesh
- 650 17
- $a ambulantní monitorování krevního tlaku $x metody $7 D018660 $2 czmesh
- 650 17
- $a hypertenze $x diagnóza $x komplikace $7 D006973 $2 czmesh
- 650 17
- $a kvalita spánku $7 D000089943 $2 czmesh
- 650 07
- $a komplikace diabetu $7 D048909 $2 czmesh
- 650 07
- $a klinická studie jako téma $x metody $7 D000068456 $2 czmesh
- 650 _7
- $a poruchy spánku a bdění $7 D012893 $2 czmesh
- 700 1_
- $a Kociánová, Eva $7 xx0230031 $u I. interní klinika kardiologická, Lékařská fakulta Univerzity Palackého a Fakultní nemocnice Olomouc, Olomouc
- 700 1_
- $a Stanke, Ladislav $u Centrum digitálního zdravotnictví, Lékařská fakulta Univerzity Palackého a Fakultní nemocnice Olomouc, Olomouc $u Národní telemedicínské centrum, Lékařská fakulta Univerzity Palackého a Fakultní nemocnice Olomouc, Olomouc $7 xx0283012
- 700 1_
- $a Štýbnar, Michal $u Centrum digitálního zdravotnictví, Lékařská fakulta Univerzity Palackého a Fakultní nemocnice Olomouc, Olomouc $7 xx0247194
- 700 1_
- $a Mizera, Jan $u Klinika plicních nemocí a tuberkulózy, Lékařská fakulta Univerzity Palackého a Fakultní nemocnice Olomouc, Olomouc $7 xx0238803
- 700 1_
- $a Vykopal, Martin $u Klinika plicních nemocí a tuberkulózy, Lékařská fakulta Univerzity Palackého a Fakultní nemocnice Olomouc, Olomouc $7 xx0282686
- 773 0_
- $t Cor et Vasa $x 0010-8650 $g Roč. 66, č. 3 (2024), s. 345-348 $w MED00010972
- 856 41
- $u https://e-coretvasa.cz/en/artkey/cor-202403-0008_ambulatory-blood-pressure-monitoring-sleep-quality-and-reliability-of-night-hypertension.php $y plný text volně přístupný
- 910 __
- $a ABA008 $b A 2980 $c 438 $y p $z 0
- 990 __
- $a 20240709 $b ABA008
- 991 __
- $a 20241025134906 $b ABA008
- 999 __
- $a ok $b bmc $g 2150033 $s 1223292
- BAS __
- $a 3
- BAS __
- $a PreBMC
- BMC __
- $a 2024 $b 66 $c 3 $d 345-348 $e 20240628 $i 0010-8650 $m Cor et Vasa $x MED00010972
- LZP __
- $c NLK192 $d 20241025 $b NLK111 $a Actavia-MED00010972-20240709