-
Je něco špatně v tomto záznamu ?
Elevating Platinum to Volumetric Capacitance: High Surface Area Electrodes through Reactive Pt Sputtering
M. Gryszel, M. Jakešová, XT. Vu, S. Ingebrandt, ED. Głowacki
Jazyk angličtina Země Německo
Typ dokumentu časopisecké články
Grantová podpora
LX22NPO5107
Ministerstvo Školství, Mládeže a Tělovýchovy
23-07432S
Grantová Agentura České Republiky
949191
HORIZON EUROPE European Research Council
PubMed
38758352
DOI
10.1002/adhm.202302400
Knihovny.cz E-zdroje
- MeSH
- bicyklické sloučeniny heterocyklické * chemie MeSH
- elektrická kapacitance * MeSH
- elektrody * MeSH
- platina * chemie MeSH
- polymery chemie MeSH
- poréznost MeSH
- povrchové vlastnosti MeSH
- Publikační typ
- časopisecké články MeSH
Platinum is the most widespread electrode material used for implantable biomedical and neuroelectronic devices, motivating exploring ways to improve its performance and understand its fundamental properties. Using reactive magnetron sputtering, PtOx is prepared, which upon partial reduction yields a porous thin-film form of platinum with favorable properties, notably record-low impedance values outcompeting other reports for platinum-based electrodes. It is established that its high electrochemical capacitance scales with thickness, in the way of volumetric capacitor materials like IrOx and poly(3,4-ethylenedioxythiophene), PEDOT. Unlike these two well-known analogs, however, it is found that PtOx capacitance is not caused by reversible pseudofaradaic reactions but rather due to high surface area. In contrast to IrOx, PtOx is not a reversible valence-change oxide, but rather a porous form of platinum. The findings show that this oxygen-containing form of Pt can place Pt electrodes on a level competitive with IrOx and PEDOT. Due to its relatively low cost and ease of preparation, PtOx can be a good choice for microfabricated bioelectronic devices.
Citace poskytuje Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc24019178
- 003
- CZ-PrNML
- 005
- 20241024111636.0
- 007
- ta
- 008
- 241015s2024 gw f 000 0|eng||
- 009
- AR
- 024 7_
- $a 10.1002/adhm.202302400 $2 doi
- 035 __
- $a (PubMed)38758352
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a gw
- 100 1_
- $a Gryszel, Maciej $u Laboratory of Organic Electronics, Department of Science and Technology, Linköping University, Bredgatan 33, Norrköping, 60174, Sweden
- 245 10
- $a Elevating Platinum to Volumetric Capacitance: High Surface Area Electrodes through Reactive Pt Sputtering / $c M. Gryszel, M. Jakešová, XT. Vu, S. Ingebrandt, ED. Głowacki
- 520 9_
- $a Platinum is the most widespread electrode material used for implantable biomedical and neuroelectronic devices, motivating exploring ways to improve its performance and understand its fundamental properties. Using reactive magnetron sputtering, PtOx is prepared, which upon partial reduction yields a porous thin-film form of platinum with favorable properties, notably record-low impedance values outcompeting other reports for platinum-based electrodes. It is established that its high electrochemical capacitance scales with thickness, in the way of volumetric capacitor materials like IrOx and poly(3,4-ethylenedioxythiophene), PEDOT. Unlike these two well-known analogs, however, it is found that PtOx capacitance is not caused by reversible pseudofaradaic reactions but rather due to high surface area. In contrast to IrOx, PtOx is not a reversible valence-change oxide, but rather a porous form of platinum. The findings show that this oxygen-containing form of Pt can place Pt electrodes on a level competitive with IrOx and PEDOT. Due to its relatively low cost and ease of preparation, PtOx can be a good choice for microfabricated bioelectronic devices.
- 650 12
- $a platina $x chemie $7 D010984
- 650 12
- $a elektrická kapacitance $7 D025802
- 650 12
- $a elektrody $7 D004566
- 650 12
- $a bicyklické sloučeniny heterocyklické $x chemie $7 D019086
- 650 _2
- $a polymery $x chemie $7 D011108
- 650 _2
- $a poréznost $7 D016062
- 650 _2
- $a povrchové vlastnosti $7 D013499
- 655 _2
- $a časopisecké články $7 D016428
- 700 1_
- $a Jakešová, Marie $u Bioelectronics Materials and Devices Laboratory, Central European Institute of Technology, Brno University of Technology, Purkyňova 123, Brno, 61200, Czech Republic $1 https://orcid.org/0000000287022303
- 700 1_
- $a Vu, Xuan Thang $u Institute of Materials in Electrical Engineering 1, RWTH Aachen University, 52074, Aachen, Germany
- 700 1_
- $a Ingebrandt, Sven $u Institute of Materials in Electrical Engineering 1, RWTH Aachen University, 52074, Aachen, Germany
- 700 1_
- $a Głowacki, Eric Daniel $u Bioelectronics Materials and Devices Laboratory, Central European Institute of Technology, Brno University of Technology, Purkyňova 123, Brno, 61200, Czech Republic $1 https://orcid.org/0000000202808017 $7 mzk20181003359
- 773 0_
- $w MED00189489 $t Advanced healthcare materials $x 2192-2659 $g Roč. 13, č. 24 (2024), s. e2302400
- 856 41
- $u https://pubmed.ncbi.nlm.nih.gov/38758352 $y Pubmed
- 910 __
- $a ABA008 $b sig $c sign $y - $z 0
- 990 __
- $a 20241015 $b ABA008
- 991 __
- $a 20241024111630 $b ABA008
- 999 __
- $a ok $b bmc $g 2201797 $s 1231151
- BAS __
- $a 3
- BAS __
- $a PreBMC-MEDLINE
- BMC __
- $a 2024 $b 13 $c 24 $d e2302400 $e 20240527 $i 2192-2659 $m Advanced healthcare materials $n Adv Healthc Mater $x MED00189489
- GRA __
- $a LX22NPO5107 $p Ministerstvo Školství, Mládeže a Tělovýchovy
- GRA __
- $a 23-07432S $p Grantová Agentura České Republiky
- GRA __
- $a 949191 $p HORIZON EUROPE European Research Council
- LZP __
- $a Pubmed-20241015