Detail
Article
Online article
FT
Medvik - BMC
  • Something wrong with this record ?

Elevating Platinum to Volumetric Capacitance: High Surface Area Electrodes through Reactive Pt Sputtering

M. Gryszel, M. Jakešová, XT. Vu, S. Ingebrandt, ED. Głowacki

. 2024 ; 13 (24) : e2302400. [pub] 20240527

Language English Country Germany

Document type Journal Article

Grant support
LX22NPO5107 Ministerstvo Školství, Mládeže a Tělovýchovy
23-07432S Grantová Agentura České Republiky
949191 HORIZON EUROPE European Research Council

Platinum is the most widespread electrode material used for implantable biomedical and neuroelectronic devices, motivating exploring ways to improve its performance and understand its fundamental properties. Using reactive magnetron sputtering, PtOx is prepared, which upon partial reduction yields a porous thin-film form of platinum with favorable properties, notably record-low impedance values outcompeting other reports for platinum-based electrodes. It is established that its high electrochemical capacitance scales with thickness, in the way of volumetric capacitor materials like IrOx and poly(3,4-ethylenedioxythiophene), PEDOT. Unlike these two well-known analogs, however, it is found that PtOx capacitance is not caused by reversible pseudofaradaic reactions but rather due to high surface area. In contrast to IrOx, PtOx is not a reversible valence-change oxide, but rather a porous form of platinum. The findings show that this oxygen-containing form of Pt can place Pt electrodes on a level competitive with IrOx and PEDOT. Due to its relatively low cost and ease of preparation, PtOx can be a good choice for microfabricated bioelectronic devices.

References provided by Crossref.org

000      
00000naa a2200000 a 4500
001      
bmc24019178
003      
CZ-PrNML
005      
20241024111636.0
007      
ta
008      
241015s2024 gw f 000 0|eng||
009      
AR
024    7_
$a 10.1002/adhm.202302400 $2 doi
035    __
$a (PubMed)38758352
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a gw
100    1_
$a Gryszel, Maciej $u Laboratory of Organic Electronics, Department of Science and Technology, Linköping University, Bredgatan 33, Norrköping, 60174, Sweden
245    10
$a Elevating Platinum to Volumetric Capacitance: High Surface Area Electrodes through Reactive Pt Sputtering / $c M. Gryszel, M. Jakešová, XT. Vu, S. Ingebrandt, ED. Głowacki
520    9_
$a Platinum is the most widespread electrode material used for implantable biomedical and neuroelectronic devices, motivating exploring ways to improve its performance and understand its fundamental properties. Using reactive magnetron sputtering, PtOx is prepared, which upon partial reduction yields a porous thin-film form of platinum with favorable properties, notably record-low impedance values outcompeting other reports for platinum-based electrodes. It is established that its high electrochemical capacitance scales with thickness, in the way of volumetric capacitor materials like IrOx and poly(3,4-ethylenedioxythiophene), PEDOT. Unlike these two well-known analogs, however, it is found that PtOx capacitance is not caused by reversible pseudofaradaic reactions but rather due to high surface area. In contrast to IrOx, PtOx is not a reversible valence-change oxide, but rather a porous form of platinum. The findings show that this oxygen-containing form of Pt can place Pt electrodes on a level competitive with IrOx and PEDOT. Due to its relatively low cost and ease of preparation, PtOx can be a good choice for microfabricated bioelectronic devices.
650    12
$a platina $x chemie $7 D010984
650    12
$a elektrická kapacitance $7 D025802
650    12
$a elektrody $7 D004566
650    12
$a bicyklické sloučeniny heterocyklické $x chemie $7 D019086
650    _2
$a polymery $x chemie $7 D011108
650    _2
$a poréznost $7 D016062
650    _2
$a povrchové vlastnosti $7 D013499
655    _2
$a časopisecké články $7 D016428
700    1_
$a Jakešová, Marie $u Bioelectronics Materials and Devices Laboratory, Central European Institute of Technology, Brno University of Technology, Purkyňova 123, Brno, 61200, Czech Republic $1 https://orcid.org/0000000287022303
700    1_
$a Vu, Xuan Thang $u Institute of Materials in Electrical Engineering 1, RWTH Aachen University, 52074, Aachen, Germany
700    1_
$a Ingebrandt, Sven $u Institute of Materials in Electrical Engineering 1, RWTH Aachen University, 52074, Aachen, Germany
700    1_
$a Głowacki, Eric Daniel $u Bioelectronics Materials and Devices Laboratory, Central European Institute of Technology, Brno University of Technology, Purkyňova 123, Brno, 61200, Czech Republic $1 https://orcid.org/0000000202808017 $7 mzk20181003359
773    0_
$w MED00189489 $t Advanced healthcare materials $x 2192-2659 $g Roč. 13, č. 24 (2024), s. e2302400
856    41
$u https://pubmed.ncbi.nlm.nih.gov/38758352 $y Pubmed
910    __
$a ABA008 $b sig $c sign $y - $z 0
990    __
$a 20241015 $b ABA008
991    __
$a 20241024111630 $b ABA008
999    __
$a ok $b bmc $g 2201797 $s 1231151
BAS    __
$a 3
BAS    __
$a PreBMC-MEDLINE
BMC    __
$a 2024 $b 13 $c 24 $d e2302400 $e 20240527 $i 2192-2659 $m Advanced healthcare materials $n Adv Healthc Mater $x MED00189489
GRA    __
$a LX22NPO5107 $p Ministerstvo Školství, Mládeže a Tělovýchovy
GRA    __
$a 23-07432S $p Grantová Agentura České Republiky
GRA    __
$a 949191 $p HORIZON EUROPE European Research Council
LZP    __
$a Pubmed-20241015

Find record

Citation metrics

Loading data ...

Archiving options

Loading data ...