-
Je něco špatně v tomto záznamu ?
A system for wireless measurement of human biomechanics
Pavel Holeka, Filip Studnička, Jan Štěpán, Jan Matyska, Jan Šlégr, Šárka Odložilová, Ján Zajak, Jiří Páral
Jazyk angličtina Země Česko
Digitální knihovna NLK
Zdroj
NLK
ROAD: Directory of Open Access Scholarly Resources
od 2011
- MeSH
- analýza chůze metody MeSH
- biomechanika * MeSH
- femoroacetabulární impingement * chirurgie diagnóza patofyziologie MeSH
- kyčelní kloub patofyziologie MeSH
- lidé MeSH
- nositelná elektronika * MeSH
- osteoartróza diagnóza patofyziologie MeSH
- retrospektivní studie MeSH
- telemedicína metody MeSH
- umělá inteligence MeSH
- Check Tag
- lidé MeSH
Background: Femoroacetabular impingement syndrome (FAI) is a complex, often post-traumatically developing impairment of the hip joint. It is characterized by ambiguous symptomatology, which makes early diagnosis difficult. Aim: The study was conducted to evaluate the applicability of a triaxial gyroscopic sensor in routine practice as an additional indication criterion for operative versus conservative treatment procedures. Methods: Ninety-two patients were included in the experimental retrospective study and 62 completed the examination. All patients signed informed consent. A gyroscopic sensor was placed on the right side of the pelvis above the hip joint and patients walked approximately 15 steps. Data were also evaluated while the patients climbed stairs. A complete clinical examination of the dynamics and physiological movements in the joint was performed. The data measured by the gyroscopic sensor were processed using differential geometry methods and subsequently evaluated using spectral analysis and neural networks. Results: FAI diagnosis using gyroscopic measurement is fast and easy to implement. Our approach to processing the gyroscopic signals used to detect the stage of osteoarthritis and post-traumatic FAI could lead to more accurate detection and capture early in FAI development. Conclusions: The obtained data are easily evaluated, interpretable, and beneficial in the diagnosis of the early stages of FAI. The results of the study show that this approach can lead to more accurate and early detection of osteoarthritis and post-traumatic FAI.
Center for Advanced Technologies Faculty of Science University of Hradec Králové Hradec Králové
Department of Military Surgery Military Faculty of Medicine University of Defense Hradec Králové
Department of Physics Faculty of Science University of Hradec Králové Hradec Králové
Citace poskytuje Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc24023018
- 003
- CZ-PrNML
- 005
- 20250218202450.0
- 007
- ta
- 008
- 250206s2024 xr ad f 000 0|eng||
- 009
- AR
- 024 7_
- $a 10.31482/mmsl.2023.038 $2 doi
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a xr
- 100 1_
- $a Holeka, Pavel $7 xx0278539 $u Department of Military Surgery, Military Faculty of Medicine, University of Defense, Hradec Králové
- 245 12
- $a A system for wireless measurement of human biomechanics / $c Pavel Holeka, Filip Studnička, Jan Štěpán, Jan Matyska, Jan Šlégr, Šárka Odložilová, Ján Zajak, Jiří Páral
- 520 3_
- $a Background: Femoroacetabular impingement syndrome (FAI) is a complex, often post-traumatically developing impairment of the hip joint. It is characterized by ambiguous symptomatology, which makes early diagnosis difficult. Aim: The study was conducted to evaluate the applicability of a triaxial gyroscopic sensor in routine practice as an additional indication criterion for operative versus conservative treatment procedures. Methods: Ninety-two patients were included in the experimental retrospective study and 62 completed the examination. All patients signed informed consent. A gyroscopic sensor was placed on the right side of the pelvis above the hip joint and patients walked approximately 15 steps. Data were also evaluated while the patients climbed stairs. A complete clinical examination of the dynamics and physiological movements in the joint was performed. The data measured by the gyroscopic sensor were processed using differential geometry methods and subsequently evaluated using spectral analysis and neural networks. Results: FAI diagnosis using gyroscopic measurement is fast and easy to implement. Our approach to processing the gyroscopic signals used to detect the stage of osteoarthritis and post-traumatic FAI could lead to more accurate detection and capture early in FAI development. Conclusions: The obtained data are easily evaluated, interpretable, and beneficial in the diagnosis of the early stages of FAI. The results of the study show that this approach can lead to more accurate and early detection of osteoarthritis and post-traumatic FAI.
- 650 07
- $a lidé $7 D006801 $2 czmesh
- 650 17
- $a femoroacetabulární impingement $x chirurgie $x diagnóza $x patofyziologie $7 D057925 $2 czmesh
- 650 07
- $a retrospektivní studie $7 D012189 $2 czmesh
- 650 07
- $a osteoartróza $x diagnóza $x patofyziologie $7 D010003 $2 czmesh
- 650 17
- $a biomechanika $7 D001696 $2 czmesh
- 650 07
- $a kyčelní kloub $x patofyziologie $7 D006621 $2 czmesh
- 650 07
- $a analýza chůze $x metody $7 D000077107 $2 czmesh
- 650 07
- $a umělá inteligence $7 D001185 $2 czmesh
- 650 07
- $a telemedicína $x metody $7 D017216 $2 czmesh
- 650 17
- $a nositelná elektronika $7 D000076251 $2 czmesh
- 700 1_
- $a Studnička, Filip $7 xx0310344 $u Department of Physics, Faculty of Science, University of Hradec Králové, Hradec Králové
- 700 1_
- $a Štěpán, Jan, $u Department of Physics, Faculty of Science, University of Hradec Králové, Hradec Králové $d 1989- $7 xx0319597
- 700 1_
- $a Matyska, Jan $u Center for Advanced Technologies, Faculty of Science, University of Hradec Králové, Hradec Králové $7 xx0327369
- 700 1_
- $a Šlégr, Jan, $u Department of Physics, Faculty of Science, University of Hradec Králové, Hradec Králové $d 1986- $7 hka2018984860
- 700 1_
- $a Odložilová, Šárka $u Department of Military Surgery, Military Faculty of Medicine, University of Defense, Hradec Králové $7 xx0305394
- 700 1_
- $a Zajak, Ján, $u Department of Military Surgery, Military Faculty of Medicine, University of Defense, Hradec Králové $d 1980- $7 xx0169036
- 700 1_
- $a Páral, Jiří, $u Department of Military Surgery, Military Faculty of Medicine, University of Defense, Hradec Králové $d 1963- $7 mzk2008469111
- 773 0_
- $t Vojenské zdravotnické listy $x 0372-7025 $g Roč. 93, č. 4 (2024), s. 323-334 $w MED00011116
- 856 41
- $u https://mmsl.cz/artkey/mms-202404-0002_a-system-for-wireless-measurement-of-human-biomechanics.php $y plný text volně přístupný
- 910 __
- $a ABA008 $b A 3 $c 1073 $y - $z 0
- 990 __
- $a 20241206 $b ABA008
- 991 __
- $a 20250218202517 $b ABA008
- 999 __
- $a ok $b bmc $g 2265126 $s 1235023
- BAS __
- $a 3
- BAS __
- $a PreBMC
- BMC __
- $a 2024 $b 93 $c 4 $d 323-334 $e 20241202 $i 0372-7025 $m Vojenské zdravotnické listy $x MED00011116
- LZP __
- $c NLK192 $d 20250218 $b NLK111 $a Actavia-MED00011116-20241206