A. Lasica, P. Filip, K. Burdová, J. Mana, F. Růžička, D. Urgošík, K. Mueller, D. Kiakou, R. Jech

. 2025 ; 15 (1) : 18652. [pub] 20250528

Language English Country England, Great Britain

Document type Journal Article

Grant support
LX22NPO5107 Ministerstvo Školství, Mládeže a Tělovýchovy
CZ-DRO-VFN64165 Ministerstvo Zdravotnictví Ceské Republiky

Tools for post-operative localization of deep brain stimulation (DBS) electrodes may be of major benefit in the evaluation of the stimulation area. However, little is known about their precision. This study compares 3 different software packages used for DBS electrode localization. T1-weighted MRI images before and after the implantation of the electrodes into the subthalamic nucleus for DBS in 105 Parkinson's disease patients were processed using the pipelines implemented in Lead-DBS, SureTune4, and Brainlab. Euclidean distance between active contacts determined by individual software packages and in repeated processing by the same and by a different operator was calculated. Furthermore, Dice coefficient for overlap of volume of tissue activated (VTA) was determined for Lead-DBS. Medians of Euclidean distances between estimated active contact locations in inter-software package comparison ranged between 1.5 mm and 2 mm. Euclidean distances in within-software package intra- and inter-rater assessments were 0.6-1 mm and 1-1.7 mm, respectively. Median intra- and inter-rater Dice coefficients for VTAs were 0.78 and 0.75, respectively. Since the median distances are close to the size of the target nucleus, any clinical use should be preceded by careful review of the outputs.

References provided by Crossref.org

000      
00000naa a2200000 a 4500
001      
bmc25015633
003      
CZ-PrNML
005      
20250731091133.0
007      
ta
008      
250708s2025 enk f 000 0|eng||
009      
AR
024    7_
$a 10.1038/s41598-025-01449-6 $2 doi
035    __
$a (PubMed)40436963
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a enk
100    1_
$a Lasica, Andrej $u Department of Neurology, First Faculty of Medicine, General University Hospital in Prague, Charles University, Kateřinská 30, 120 00, Prague, Czech Republic
245    10
$a Precision of post-operative localization of deep brain stimulation electrodes / $c A. Lasica, P. Filip, K. Burdová, J. Mana, F. Růžička, D. Urgošík, K. Mueller, D. Kiakou, R. Jech
520    9_
$a Tools for post-operative localization of deep brain stimulation (DBS) electrodes may be of major benefit in the evaluation of the stimulation area. However, little is known about their precision. This study compares 3 different software packages used for DBS electrode localization. T1-weighted MRI images before and after the implantation of the electrodes into the subthalamic nucleus for DBS in 105 Parkinson's disease patients were processed using the pipelines implemented in Lead-DBS, SureTune4, and Brainlab. Euclidean distance between active contacts determined by individual software packages and in repeated processing by the same and by a different operator was calculated. Furthermore, Dice coefficient for overlap of volume of tissue activated (VTA) was determined for Lead-DBS. Medians of Euclidean distances between estimated active contact locations in inter-software package comparison ranged between 1.5 mm and 2 mm. Euclidean distances in within-software package intra- and inter-rater assessments were 0.6-1 mm and 1-1.7 mm, respectively. Median intra- and inter-rater Dice coefficients for VTAs were 0.78 and 0.75, respectively. Since the median distances are close to the size of the target nucleus, any clinical use should be preceded by careful review of the outputs.
650    _2
$a lidé $7 D006801
650    12
$a hluboká mozková stimulace $x metody $x přístrojové vybavení $7 D046690
650    12
$a Parkinsonova nemoc $x terapie $7 D010300
650    _2
$a magnetická rezonanční tomografie $7 D008279
650    _2
$a mužské pohlaví $7 D008297
650    12
$a implantované elektrody $7 D004567
650    _2
$a ženské pohlaví $7 D005260
650    _2
$a nucleus subthalamicus $x chirurgie $7 D020531
650    _2
$a lidé středního věku $7 D008875
650    _2
$a senioři $7 D000368
650    _2
$a software $7 D012984
655    _2
$a časopisecké články $7 D016428
700    1_
$a Filip, Pavel $u Department of Neurology, First Faculty of Medicine, General University Hospital in Prague, Charles University, Kateřinská 30, 120 00, Prague, Czech Republic $u Center for Magnetic Resonance Research (CMRR), University of Minnesota, Minneapolis, MN, USA
700    1_
$a Burdová, Kristína $u Department of Neurology, First Faculty of Medicine, General University Hospital in Prague, Charles University, Kateřinská 30, 120 00, Prague, Czech Republic
700    1_
$a Mana, Josef $u Department of Neurology, First Faculty of Medicine, General University Hospital in Prague, Charles University, Kateřinská 30, 120 00, Prague, Czech Republic
700    1_
$a Růžička, Filip $u Department of Neurology, First Faculty of Medicine, General University Hospital in Prague, Charles University, Kateřinská 30, 120 00, Prague, Czech Republic
700    1_
$a Urgošík, Dušan $u Department of Radiology, Na Homolce Hospital, Prague, Czech Republic
700    1_
$a Mueller, Karsten $u Department of Neurology, First Faculty of Medicine, General University Hospital in Prague, Charles University, Kateřinská 30, 120 00, Prague, Czech Republic $u Max Planck Institute for Human Cognitive and Brain Sciences, Leipzig, Germany
700    1_
$a Kiakou, Dimitra $u Department of Neurology, First Faculty of Medicine, General University Hospital in Prague, Charles University, Kateřinská 30, 120 00, Prague, Czech Republic $u Max Planck Institute for Human Cognitive and Brain Sciences, Leipzig, Germany
700    1_
$a Jech, Robert $u Department of Neurology, First Faculty of Medicine, General University Hospital in Prague, Charles University, Kateřinská 30, 120 00, Prague, Czech Republic. jech@cesnet.cz
773    0_
$w MED00182195 $t Scientific reports $x 2045-2322 $g Roč. 15, č. 1 (2025), s. 18652
856    41
$u https://pubmed.ncbi.nlm.nih.gov/40436963 $y Pubmed
910    __
$a ABA008 $b sig $c sign $y - $z 0
990    __
$a 20250708 $b ABA008
991    __
$a 20250731091128 $b ABA008
999    __
$a ok $b bmc $g 2366471 $s 1252758
BAS    __
$a 3
BAS    __
$a PreBMC-MEDLINE
BMC    __
$a 2025 $b 15 $c 1 $d 18652 $e 20250528 $i 2045-2322 $m Scientific reports $n Sci Rep $x MED00182195
GRA    __
$a LX22NPO5107 $p Ministerstvo Školství, Mládeže a Tělovýchovy
GRA    __
$a CZ-DRO-VFN64165 $p Ministerstvo Zdravotnictví Ceské Republiky
LZP    __
$a Pubmed-20250708

Find record

Citation metrics

Loading data ...

Archiving options

Loading data ...