Extrahepatic portal venous laceration in TIPS treated with stent graft placement
Language English Country Greece Media print
Document type Case Reports, Journal Article, Research Support, Non-U.S. Gov't
PubMed
9222668
Knihovny.cz E-resources
- MeSH
- Blood Vessel Prosthesis * MeSH
- Adult MeSH
- Hemoperitoneum etiology MeSH
- Humans MeSH
- Adolescent MeSH
- Intraoperative Complications diagnostic imaging surgery MeSH
- Radiography MeSH
- Aged MeSH
- Stents * MeSH
- Portasystemic Shunt, Transjugular Intrahepatic adverse effects MeSH
- Portal Vein diagnostic imaging injuries MeSH
- Check Tag
- Adult MeSH
- Humans MeSH
- Adolescent MeSH
- Male MeSH
- Aged MeSH
- Publication type
- Journal Article MeSH
- Case Reports MeSH
- Research Support, Non-U.S. Gov't MeSH
Three cases of intraperitoneal bleeding from extrahepatic portal vein laceration were observed in a series of 104 patients with TIPS. In one patient, bleeding continued after Wallstent placement and the patient died during an emergency laparotomy. Bleeding was stopped in the other two patients by using a stent graft rather than a regular stent. One shunt remained patent and outflow stenosis developed in 3 months. The other shunt thrombosed in 5 months. Both shunts were fully reopened.