Paclitaxel isomerisation in polymeric micelles based on hydrophobized hyaluronic acid
Jazyk angličtina Země Nizozemsko Médium print-electronic
Typ dokumentu časopisecké články
PubMed
24614580
DOI
10.1016/j.ijpharm.2014.03.024
PII: S0378-5173(14)00167-7
Knihovny.cz E-zdroje
- Klíčová slova
- Hyaluronan, Hyaluronic acid (PubChem CID: 453617), Isomer, Paclitaxel, Paclitaxel (PubChem CID: 44155032), Polymeric micelle, Stability,
- MeSH
- antitumorózní látky fytogenní aplikace a dávkování chemie MeSH
- fibroblasty účinky léků MeSH
- HCT116 buňky MeSH
- hydrofobní a hydrofilní interakce MeSH
- isomerie MeSH
- kultivované buňky MeSH
- kyselina hyaluronová aplikace a dávkování chemie MeSH
- lidé MeSH
- micely * MeSH
- nosiče léků aplikace a dávkování chemie MeSH
- paclitaxel aplikace a dávkování chemie MeSH
- polymery aplikace a dávkování chemie MeSH
- viabilita buněk účinky léků MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
- Názvy látek
- antitumorózní látky fytogenní MeSH
- kyselina hyaluronová MeSH
- micely * MeSH
- nosiče léků MeSH
- paclitaxel MeSH
- polymery MeSH
Physical and chemical structure of paclitaxel (PTX) was studied after its incorporation into polymeric micelles made of hyaluronic acid (HA) (Mw=15 kDa) grafted with C6 or C18:1 acyl chains. PTX was physically incorporated into the micellar core by solvent evaporation technique. Maximum loading capacity for HAC6 and HAC18:1 was determined to be 2 and 14 wt.%, respectively. The loading efficiency was higher for HAC18:1 and reached 70%. Independently of the derivative, loaded HA micelles had spherical size of approximately 60-80 nm and demonstrated slow and sustained release of PTX in vitro. PTX largely changed its form from crystalline to amorphous after its incorporation into the micelle's interior. This transformation increased PTX sensitivity towards stressing conditions, mainly to UV light exposure, during which the structure of amorphous PTX isomerized and formed C3C11 bond within its structure. In vitro cytotoxicity assay revealed that polymeric micelles loaded with PTX isomer had higher cytotoxic effect to normal human dermal fibroblasts (NHDF) and human colon carcinoma cells (HCT-116) than the same micelles loaded with non-isomerized PTX. Further observation indicated that PTX isomer influenced in different ways cell morphology and markers of cell cycle. Taken together, PTX isomer loaded in nanocarrier systems may have improved anticancer activity in vivo than pure PTX.
Citace poskytuje Crossref.org