This study describes an integrated NH3 sensor based on a hydrogenated nanocrystalline diamond (NCD)-sensitive layer coated on an interdigitated electrode structure. The gas sensing properties of the sensor structure were examined using a reducing gas (NH3) at room temperature and were found to be dependent on the electrode arrangement. A pronounced response of the sensor, which was comprised of dense electrode arrays (of 50 µm separation distance), was observed. The sensor functionality was explained by the surface transfer doping effect. Moreover, the three-dimensional model of the current density distribution of the hydrogenated NCD describes the transient flow of electrons between interdigitated electrodes and the hydrogenated NCD surface, that is, the formation of a closed current loop.
Zobrazit více v PubMed
Helwig A, Müller G, Sberveglieri G, Eickhoff M. J Sens. 2009;2009:No. 620720. doi: 10.1155/2009/620720. DOI
Davydova M, Stuchlik M, Rezek B, Larsson K, Kromka A. Sens Actuators, B. 2013;188:675–680. doi: 10.1016/j.snb.2013.07.079. DOI
Beer S, Helwig A, Müller G, Garrido J, Stutzmann M. Sens Actuators, B. 2013;181:894–903. doi: 10.1016/j.snb.2013.02.072. DOI
Groß A, Beulertz G, Marr I, Kubinski D J, Visser J H, Moos R. Sensors. 2012;12:2831–2850. doi: 10.3390/s120302831. PubMed DOI PMC
Marr I, Groß A, Moos R. J Sens Sens Syst. 2014;3:29–46. doi: 10.5194/jsss-3-29-2014. DOI
Roadman M J, Scudlark J, Meisinger J J, Ullman W J. Atmos Environ. 2003;37:2317–2325. doi: 10.1016/S1352-2310(03)00163-8. DOI
Geupel A, Schönauer D, Röder-Roith U, Kubinski D J, Mulla S, Ballinger T H, Chen H-Y, Visser J H, Moos R. Sens Actuators, B. 2010;145:756–761. doi: 10.1016/j.snb.2010.01.036. DOI
Hayashi K, Yamanaka S, Watanabe H, Sekiguchi T, Okushi H, Kajimura K. J Appl Phys. 1997;81:744–753. doi: 10.1063/1.364299. DOI
Kromka A, Davydova M, Rezek B, Vanecek M, Stuchlik M, Exnar P, Kalbac M. Diamond Relat Mater. 2010;19:196–200. doi: 10.1016/j.diamond.2009.10.006. DOI
Davydova M, Stuchlik M, Rezek B, Kromka A. Vacuum. 2012;86:599–602. doi: 10.1016/j.vacuum.2011.07.025. DOI
Kromka A, Babchenko O, Izak T, Hruska K, Rezek B. Vacuum. 2012;86:776–779. doi: 10.1016/j.vacuum.2011.07.008. DOI
Pop-Georgievski O, Neykova N, Proks V, Houdkova J, Ukraintsev E, Zemek J, Kromka A, Rypaček F. Thin Solid Films. 2013;543:180–186. doi: 10.1016/j.tsf.2012.11.128. DOI
Singh K V, Bhura D K, Nandamuri G, Whited A M, Evans D, King J, Solanki R. Langmuir. 2011;27:13931–13939. doi: 10.1021/la202546a. PubMed DOI
Helwig A, Müller G, Garrido J A, Eickhoff M. Sens Actuators, B. 2008;133:156–165. doi: 10.1016/j.snb.2008.02.007. DOI
Ri, Gi S, Tashiro K, Tanaka S, Fujisawa T, Kimura H, Kurosu T, Iida M. Jpn J Appl Phys. 1999;38:3492. doi: 10.1143/JJAP.38.3492. DOI
Wang Q, Qu S L, Fu S Y, Liu W J, Li J J, Gu C Z. J Appl Phys. 2007;102:103714. doi: 10.1063/1.2817465. DOI
Maier F, Riedel M, Mantel B, Ristein J, Ley L. Phys Rev Lett. 2000;85:3472–3475. doi: 10.1103/PhysRevLett.85.3472. PubMed DOI
Chakrapani V, Angus J C, Anderson A B, Wolter S D, Stoner B R, Sumanasekera G U. Science. 2007;318:1424–1430. doi: 10.1126/science.1148841. PubMed DOI
Izak T, Sveshnikov A, Demo P, Kromka A. Phys Status Solidi B. 2013;250:2753–2758. doi: 10.1002/pssb.201300117. DOI
Neykova N, Kozak H, Ledinsky M, Kromka A. Vacuum. 2012;86:603–607. doi: 10.1016/j.vacuum.2011.07.055. DOI
Improved Gas Sensing Capabilities of MoS2/Diamond Heterostructures at Room Temperature
Hydrogen-Terminated Diamond Surface as a Gas Sensor: A Comparative Study of Its Sensitivities
Gas-sensing behaviour of ZnO/diamond nanostructures