Three-dimensional rotational angiography of the left atrium and the oesophagus: the short-term mobility of the oesophagus and the stability of the fused three-dimensional model of the left atrium and the oesophagus during catheter ablation for atrial fibrillation
Jazyk angličtina Země Velká Británie, Anglie Médium print
Typ dokumentu časopisecké články
PubMed
27915264
DOI
10.1093/europace/euw187
PII: euw187
Knihovny.cz E-zdroje
- Klíčová slova
- 3D Rotational angiography of the left atrium and oesophagus, Atrioesophageal fistula, Catheter ablation of atrial fibrillation, Image integration, Mobility of the oesophagus,
- MeSH
- anatomická značka MeSH
- angiografie metody MeSH
- časové faktory MeSH
- chirurgie s pomocí počítače škodlivé účinky metody MeSH
- délka operace MeSH
- ezofágus diagnostické zobrazování MeSH
- fibrilace síní diagnostické zobrazování patofyziologie chirurgie MeSH
- fluoroskopie MeSH
- intervenční radiografie metody MeSH
- katetrizační ablace škodlivé účinky metody MeSH
- lidé středního věku MeSH
- lidé MeSH
- pohyb těles MeSH
- prediktivní hodnota testů MeSH
- prospektivní studie MeSH
- rentgenový obraz - interpretace počítačová * MeSH
- reprodukovatelnost výsledků MeSH
- senioři MeSH
- srdeční síně diagnostické zobrazování patofyziologie chirurgie MeSH
- výsledek terapie MeSH
- zobrazování trojrozměrné * MeSH
- Check Tag
- lidé středního věku MeSH
- lidé MeSH
- mužské pohlaví MeSH
- senioři MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
AIMS: The objective of this study was to evaluate the mobility of the oesophagus and the stability of the three-dimensional (3D) model of the oesophagus using 3D rotational angiography (3DRA) of the left atrium (LA) and the oesophagus, fused with live fluoroscopy during catheter ablation for atrial fibrillation. METHODS AND RESULTS: From March 2015 to September 2015, 3DRA of the LA and the oesophagus was performed in 33 patients before catheter ablation for atrial fibrillation. Control contrast oesophagography was performed every 30 min. The positions of the oesophagograms and the 3D model of the LA and the oesophagus were repeatedly measured and compared with the spine. The average shift of the oesophagus ranged from 2.7 ± 2.2 to 5.0 ± 3.5 mm. The average real-time oesophageal shift ranged from 2.7 ± 2.2 to 3.8 ± 3.4 mm. No significant shift was detected until the 90th minute of the procedure. The average shift of the 3D model of the LA and the oesophagus ranged from 1.4 ± 1.8 to 3.3 ± 3.0 mm (right-left direction) and from 0.9 ± 1.2 to 2.2 ± 1.3 mm (craniocaudal direction). During the 2 h procedure, there were no significant shifts of the model. CONCLUSION: During catheter ablation for atrial fibrillation, there is no significant change in the position of the oesophagus until the 90th minute of the procedure and no significant shift in the 3D model of the LA and the oesophagus. The 3D model of the oesophagus reliably depicts the position of the oesophagus during the entire procedure.