Content of distinct metals in periprosthetic tissues and pseudosynovial joint fluid in patients with total joint arthroplasty
Jazyk angličtina Země Spojené státy americké Médium print-electronic
Typ dokumentu časopisecké články, práce podpořená grantem
PubMed
29663650
DOI
10.1002/jbm.b.34137
Knihovny.cz E-zdroje
- Klíčová slova
- inductively coupled plasma mass spectrometry, joint fluid, metal release, periprosthetic tissue, total joint replacement,
- MeSH
- dospělí MeSH
- kovy farmakokinetika MeSH
- kyčelní protézy škodlivé účinky MeSH
- lidé středního věku MeSH
- lidé MeSH
- náhrada kyčelního kloubu * MeSH
- prospektivní studie MeSH
- protézy kolene škodlivé účinky MeSH
- selhání protézy škodlivé účinky MeSH
- senioři nad 80 let MeSH
- senioři MeSH
- synoviální tekutina metabolismus MeSH
- totální endoprotéza kolene * MeSH
- Check Tag
- dospělí MeSH
- lidé středního věku MeSH
- lidé MeSH
- mužské pohlaví MeSH
- senioři nad 80 let MeSH
- senioři MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH
- Názvy látek
- kovy MeSH
This prospective study examined the content of metals released from total joint arthroplasty into joint fluid, whole blood and periprosthetic tissues. We determined the levels of Ti, V, Nb, Co, Cr, and Mo, using inductively coupled plasma mass spectrometry, in samples from patients who underwent reoperation of total hip or knee arthroplasty. All of the patients (n = 117) included in the study had either metal on polyethylene or ceramic on polyethylene-bearing pairs. First, our results conclusively showed that the majority of released metals were deposited in periprosthetic tissues. In this context, the bloodstream turned out to be an ineffective biomarker of the effects occurring in local tissues. Second, there was a clear time-dependent nature of metallic accumulation. Based on our extensive dataset, we found significantly elevated levels of the released metals in joint fluid and periprosthetic tissues originating from loosened implants compared to stable ones, as well as recognizable differences between the groups with stable implants and aseptic loosening. Finally, it was proved that the concentrations of metals decreased dependent on the distance of the tissue from the implant. © 2018 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 107B: 454-462, 2019.