Impact of His bundle pacing on right ventricular performance in patients undergoing permanent pacemaker implantation

. 2021 Jun ; 44 (6) : 986-994. [epub] 20210507

Jazyk angličtina Země Spojené státy americké Médium print-electronic

Typ dokumentu časopisecké články

Perzistentní odkaz   https://www.medvik.cz/link/pmid33890685

BACKGROUND: His-Bundle pacing (HBP) is an emerging technique for physiological pacing. However, its effects on right ventricle (RV) performance are still unknown. METHODS: We enrolled consecutive patients with an indication for pacemaker (PM) implantation to compare HBP versus RV pacing (RVP) effects on RV performance. Patients were evaluated before implantation and after 6 months by a transthoracic echocardiogram. RESULTS: A total of 84 patients (age 75.1±7.9 years, 64% male) were enrolled, 42 patients (50%) underwent successful HBP, and 42 patients (50%) apical RVP. At follow up, we found a significant improvement in RV-FAC (Fractional Area Change)% [baseline: HBP 34 IQR (31-37) vs. RVP 33 IQR (29.7-37.2),p = .602; 6-months: HBP 37 IQR (33-39) vs. RVP 30 IQR (27.7-35), p < .0001] and RV-GLS (Global Longitudinal Strain)% [baseline: HBP -18 IQR (-20.2 to -15) vs. RVP -16 IQR (-18.7 to -14), p = .150; 6-months: HBP -20 IQR(-23 to -17) vs. RVP -13.5 IQR (-16 to -11), p < .0001] with HBP whereas RVP was associated with a significant decline in both parameters. RVP was also associated with a significant worsening of tricuspid annular plane systolic excursion (TAPSE) (p < .0001) and S wave velocity (p < .0001) at follow up. Conversely from RVP, HBP significantly improved pulmonary artery systolic pressure (PASP) [baseline: HBP 38 IQR (32-42) mmHg vs. RVP 34 IQR (31.5-37) mmHg,p = .060; 6-months: HBP 32 IQR (26-38) mmHg vs. RVP 39 IQR (36-41) mmHg, p < .0001] and tricuspid regurgitation (p = .005) irrespectively from lead position above or below the tricuspid valve. CONCLUSIONS: In patients undergoing PM implantation, HBP ensues a beneficial and protective impact on RV performance compared with RVP.

Zobrazit více v PubMed

Kusumoto FM, Schoenfeld MH, Barrett C, et al. 2018 ACC/AHA/HRS guideline on the evaluation and management of patients with Bradycardia and Cardiac Conduction delay. J Am Coll Cardiol. 2019;74(7):e51-e156.

Wilkoff BL, Cook JR, Epstein AE, et al. Dual-chamber pacing-or ventricular backup pacing in patients with an implantable defibrillator: the Dual Chamber and VVI Implantable Defibrillator (DAVID) Trial. J Am Med Assoc. 2002;288(24):3115-3123.

Ghio S, Gavazzi A, Campana C, et al. Independent and additive prognostic value of right ventricular systolic function and pulmonary artery pressure in patients with chronic heart failure. J Am Coll Cardiol. 2001;37:183-188.

Lee KL, Burnes JE, Mullen TJ, et al. Avoidance of right ventricular pacing in cardiac resynchronization therapy improves right ventricular hemodynamics in heart failure patients. J Cardiovasc Electrophysiol. 2007;18:497-504.

Lewis AJM, Foley P, Whinnett Z, Keene D, Chandrasekaran B. His bundle pacing: a new strategy for physiological ventricular activation. J Am Heart Assoc. 2019;8(6):e010972.

Zhang S, Zhou X, Gold MR. Left bundle branch pacing: jACC review topic of the week. J Am Coll Cardiol. 2019;74(24):3039-3049.

Su L, Wang S, Wu S, et al. Long-term safety and feasibility of left bundle branch pacing in a large single-center study. Circ Arrhythm Electrophysiol. 2021;14(2):e009261.

Kron J, Padala SK. AV block post-TAVR: when AV Block is high, we go low (in the conduction system). JACC: Clin Electrophysiol. 2020;6(6):658-660.

Salden FCWM, Luermans JGLM, Westra SW, et al. Short-term hemodynamic and electrophysiological effects of cardiac resynchronization by left ventricular septal pacing. J Am Coll Cardiol. 2020;75(4):347-359.

Pastore G, Aggio S, Baracca E, et al. Hisian area and right ventricular apical pacing differently affect left atrial function: an intra-patients evaluation. Europace. 2014;16(4):1033-1039.

Jastrzȩbski M, Moskal P, Bednarek A, Kiełbasa G, Vijayaraman P, Czarnecka D. Programmed His Bundle pacing: a novel maneuver for the diagnosis of His Bundle capture. Circ Arrhythmia Electrophysiol. 2019;12:e006816.

Jastrzȩbski M, Moskal P, Curila K, et al. Electrocardiographic characterization of non-selective His-bundle pacing: validation of novel diagnostic criteria. Europace. 2019;21(12):1857-1864.

Vijayaraman P, Dandamudi G, Zanon F, et al. Permanent his bundle pacing: recommendations from a multicenter his bundle pacing collaborative working group for standardization of definitions, implant measurements, and follow-up. Hear Rhythm. 2018;15(3):460-468.

Jones N, Burns AT, Prior DL. Echocardiographic assessment of the Right Ventricle-State of the art. Heart Lung Circ. 2019;28(9):1339-1350.

Badano LP, Kolias TJ, Muraru D, et al. Standardization of left atrial, right ventricular, and right atrial deformation imaging using two-dimensional speckle tracking echocardiography: a consensus document of the EACVI/ASE/Industry Task Force to standardize deformation imaging. Eur Heart J Cardiovasc Imaging. 2018;19(6):591-600.

Rudski LG, Lai WW, Afilalo J, et al. Guidelines for the Echocardiographic assessment of the right heart in adults: a report from the American Society of Echocardiography. endorsed by the European Association of Echocardiography, a registered branch of the European Society of Cardiology, and the Canadian Society of Echocardiography. J Am Soc Echocardiogr. 2010;23(7):685-713.

Ebrille E, DeSimone CV, Vaidya VR, Chahal AA, Nkomo VT, Asirvatham SJ. Ventricular pacing - Electromechanical consequences and valvular function. Indian Pacing Electrophysiol J. 2016;16(1):19-30.

Tops LF, Schalij MJ, Bax JJ. The effects of right ventricular apical pacing on ventricular function and dyssynchrony. Implications for therapy. J Am Coll Cardiol. 2009;54(9):764-776.

Strocchi M, Lee AWC, Neic A, et al. His bundle and left bundle pacing with optimised atrio-ventricular delay achieve superior electrical synchrony over endocardial and epicardial pacing in left bundle branch block patients. Heart Rhythm. 2020;17(11):1922-1929.

Varma N, Jia P, Ramanathan C, Rudy Y. RV electrical activation in heart failure during right, left, and biventricular pacing. JACC Cardiovasc Imaging. 2010;3(6):567-575.

Ali N, Keene D, Arnold A, Shun-Shin M, Whinnett ZI, Sohaib SA. His bundle pacing: a new frontier in the treatment of heart failure. Arrhythmia and Electrophysiol Rev. 2018;7(2):103-110.

Sharma PS, Dandamudi G, Herweg B, et al. Permanent His-bundle pacing as an alternative to biventricular pacing for cardiac resynchronization therapy: a multicenter experience. Hear Rhythm. 2018;15(3):413-420.

Saito M, Iannaccone A, Kaye G, Negishi K, Kosmala W, Marwick TH. Effect of right ventricular pacing on right ventricular mechanics and tricuspid regurgitation in patients with high-grade atrioventricular block and sinus rhythm (from the protection of left ventricular function during right ventricular pacing study). Am J Cardiol. 2015;116(12):1875-1882.

Lee JZ, Low SW, Pasha AK, Howe CL, Lee KS, Suryanarayana PG. Comparison of tricuspid annular plane systolic excursion with fractional area change for the evaluation of right ventricular systolic function: a meta-analysis. Open Hear. 2018;5:e000667.

Bednarek A, Ionita O, Moskal P, et al. Nonselective versus selective His bundle pacing: an acute intrapatient speckle-tracking strain echocardiographic study. J Cardiovasc Electrophysiol. 2021;32(1):117-125.

Giusca S, Dambrauskaite V, Scheurwegs C, et al. Deformation imaging describes right ventricular function better than longitudinal displacement of the tricuspid ring. Heart. 2010;96(4):281-288.

Pavlicek M, Wahl A, Rutz T, et al. Right ventricular systolic function assessment: rank of echocardiographic methods vs. cardiac magnetic resonance imaging. Eur J Echocardiogr. 2011;12(11):871-880.

Houard L, Militaru S, Tanaka K, et al. Test-retest reliability of left and right ventricular systolic function by new and conventional echocardiographic and cardiac magnetic resonance parameters. Eur Heart J Cardiovasc Imaging. 2020;22(1):51.

Khurshid S, Epstein AE, Verdino RJ, et al. Incidence and predictors of right ventricular pacing-induced cardiomyopathy. Hear Rhythm. 2014;11(9):1619-1625.

Sharma PS, Vijayaraman P, Ellenbogen KA. Permanent His bundle pacing: shaping the future of physiological ventricular pacing. Nat Rev Cardiol. 2020;17(1):22-36.

Trankle CR, Gertz ZM, Koneru JN, et al. Severe tricuspid regurgitation due to interactions with right ventricular permanent pacemaker or defibrillator leads. PACE - Pacing and. Clin Electrophysiol. 2018;41(7):845-853.

Al-Bawardy R, Krishnaswamy A, Rajeswaran J, et al. Tricuspid regurgitation and implantable devices. PACE - Pacing Clin Electrophysiol. 2015;38(2):259-266.

Huang W, Wu S, Vijayaraman P, et al.. Cardiac resynchronization therapy in patients with nonischemic cardiomyopathy using left bundle branch pacing. JACC Clin Electrophysiol. 2020;6(7):849-858.

Cabrera JÁ, Anderson RH, Macías Y, et al. Variable arrangement of the atrioventricular conduction axis within the triangle of koch: implications for permanent his bundle pacing. JACC Clin Electrophysiol. 2020;6(4):362-377.

Padala SK, Cabrera JA, Ellenbogen KA. Anatomy of the cardiac conduction system. Pacing Clin Electrophysiol. 2021;44(1):15-25.

Teng AE, Lustgarten DL, Vijayaraman P, et al. Usefulness of His bundle pacing to achieve electrical resynchronization in patients with complete left bundle branch block and the relation between native QRS axis, duration, and normalization. Am J Cardiol. 2016; 118(4):527-534.

Vijayaraman P, Naperkowski A, Subzposh FA, et al. Permanent His-bundle pacing: long-term lead performance and clinical outcomes. Heart Rhythm. 2018;15(5):696-702.

Padala SK, Ellenbogen KA. Selective versus nonselective His bundle pacing: does it matter?. JACC: Clin Electrophysiol. 2019;5(7):775-777.

Curila K, Prochazkova R, Jurak P, et al. Both selective and nonselective His bundle, but not myocardial, pacing preserve ventricular electrical synchrony assessed by ultra-high-frequency ECG. Heart Rhythm. 2020;17(4):607-614.

Najít záznam

Citační ukazatele

Nahrávání dat ...

Možnosti archivace

Nahrávání dat ...