Acute efficacy of contiguous versus temporally discontiguous point-by-point radiofrequency pulmonary vein isolation in patients with paroxysmal atrial fibrillation: a randomized study
Language English Country Netherlands Media print-electronic
Document type Journal Article, Randomized Controlled Trial
PubMed
34988847
DOI
10.1007/s10840-021-01113-9
PII: 10.1007/s10840-021-01113-9
Knihovny.cz E-resources
- Keywords
- Ablation, Ablation index, Atrial fibrillation, Contiguous lesion, Interlesion distance,
- MeSH
- Adenosine MeSH
- Atrial Fibrillation * surgery MeSH
- Catheter Ablation * MeSH
- Humans MeSH
- Recurrence MeSH
- Pulmonary Veins * surgery MeSH
- Treatment Outcome MeSH
- Check Tag
- Humans MeSH
- Male MeSH
- Female MeSH
- Publication type
- Journal Article MeSH
- Randomized Controlled Trial MeSH
- Names of Substances
- Adenosine MeSH
PURPOSE: Durable pulmonary vein (PV) isolation (PVI) determines the clinical success of catheter ablation for atrial fibrillation. In this randomized study, we investigated whether the temporally discontiguous deployment of ablation lesions adversely affected the acute efficacy of PVI. METHODS: Thirty-six consecutive patients with drug-refractory paroxysmal atrial fibrillation (aged 59 ± 11, 58% males) were randomized 1:1 to either discontiguous (D-PVI) or contiguous (C-PVI) encircling radiofrequency (RF) lesions around ipsilateral PVs. A contact force-sensing catheter was used targeting a final interlesion distance < 6 mm and the ablation index of 400-450 (anterior wall) and 300-350 (posterior wall). The study endpoint was defined as failure of first-pass PVI or acute PV reconnection during a waiting time (> 30 min) followed by adenosine challenge. RESULTS: The total RF time, number of RF lesions, and mean interlesion distance were comparable in both groups. Total endpoint rates were 1/36 (3%) in the D-PVI vs 4/36 (11%) in the C-PVI groups; P = 0.34 for superiority, P = 0.008 for non-inferiority. Adenosine-induced reconnection of right PVs was the only endpoint in the D-PVI group. In the C-PVI group, first-pass PVI failed in 2 right PVs and spontaneous reconnection occurred in 2 other circles (left and right PVs). CONCLUSION: Temporally discontiguous deployment of RF lesions is not associated with lower procedural PVI efficacy when strict criteria for interlesion distance and ablation index are applied. The development of local edema around each ablation site does not prevent effective RF lesion formation at adjacent positions. TRIAL REGISTRATION: clinicaltrials.gov (NCT03332862).
1st Faculty of Medicine Charles University Prague Czech Republic
3rd Faculty of Medicine Charles University Prague Czech Republic
Institute for Clinical and Experimental Medicine Prague Czech Republic
University Hospital Kralovske Vinohrady Prague Czech Republic
See more in PubMed
Piccini JP, Lopes RD, Kong MH, Hasselblad V, Jackson K, Al-Khatib SM. Pulmonary vein isolation for the maintenance of sinus rhythm in patients with atrial fibrillation: a meta-analysis of randomized, controlled trials. Circ Arrhythm Electrophysiol. 2009;2:626–33. DOI
Wilber DJ, Pappone C, Neuzil P, De Paola A, Marchlinski F, Natale A, et al. Comparison of antiarrhythmic drug therapy and radiofrequency catheter ablation in patients with paroxysmal atrial fibrillation: a randomized controlled trial. JAMA. 2010;303:333–40. DOI
Wokhlu A, Monahan KH, Hodge DO, Asirvatham SJ, Friedman PA, Munger TM, et al. Long-term quality of life after ablation of atrial fibrillation the impact of recurrence, symptom relief, and placebo effect. J Am Coll Cardiol. 2010;55:2308–16. DOI
Ouyang F, Antz M, Ernst S, Hachiya H, Mavrakis H, Deger FT, et al. Recovered pulmonary vein conduction as a dominant factor for recurrent atrial tachyarrhythmias after complete circular isolation of the pulmonary veins: lessons from double Lasso technique. Circulation. 2005;111:127–35. DOI
Hussein A, Das M, Riva S, Morgan M, Ronayne C, Sahni A, et al. Use of ablation index-guided ablation results in high rates of durable pulmonary vein isolation and freedom from arrhythmia in persistent atrial fibrillation patients. Circ Arrhythm Electrophysiol. 2018;11:e006576. DOI
Taghji P, El Haddad M, Phlips T, Wolf M, Knecht S, Vandekerckhove Y, et al. Evaluation of a strategy aiming to enclose the pulmonary veins with contiguous and optimized radiofrequency lesions in paroxysmal atrial fibrillation: a pilot study. JACC Clin Electrophysiol. 2018;4:99–108. DOI
Kautzner J, Neuzil P, Lambert H, Peichl P, Petru J, Cihak R, et al. EFFICAS II: optimization of catheter contact force improves outcome of pulmonary vein isolation for paroxysmal atrial fibrillation. Europace. 2015;17:1229–35. DOI
Yagishita A, De Oliveira S, Cakulev I, Gimbel JR, Sparano D, Manyam H, et al. Correlation of left atrial voltage distribution between sinus rhythm and atrial fibrillation: identifying structural remodeling by 3-D electroanatomic mapping irrespective of the rhythm. J Cardiovasc Electrophysiol. 2016;27:905–12. DOI
Munkler P, Kroger S, Liosis S, Abdin A, Lyan E, Eitel C, et al. Ablation index for catheter ablation of atrial fibrillation – clinical applicability and comparison with force-time integral. Circ J. 2018;82:2722–7. DOI
Das M, Loveday JJ, Wynn GJ, Gomes S, Saeed Y, Bonnett LJ, et al. Ablation index, a novel marker of ablation lesion quality: prediction of pulmonary vein reconnection at repeat electrophysiology study and regional differences in target values. Europace. 2017;19:775–83. PubMed
Tanaka N, Inoue K, Tanaka K, Toyoshima Y, Oka T, Okada M, et al. Automated ablation annotation algorithm reduces re-conduction of isolated pulmonary vein and improves outcome after catheter ablation for atrial fibrillation. Circ J. 2017;81:1596–602. DOI
Park CI, Lehrmann H, Keyl C, Weber R, Schiebeling J, Allgeier J, et al. Mechanisms of pulmonary vein reconnection after radiofrequency ablation of atrial fibrillation: the deterministic role of contact force and interlesion distance. J Cardiovasc Electrophysiol. 2014;25:701–8. DOI
Zucchelli G, Sirico G, Rebellato L, Marini M, Stabile G, Del Greco M, et al. Contiguity between ablation lesions and strict catheter stability settings assessed by VISITAG(TM) module improve clinical outcomes of paroxysmal atrial fibrillation ablation – results from the VISITALY Study. Circ J. 2018;82:974–82. DOI
Ren JF, Callans DJ, Schwartzman D, Michele JJ, Marchlinski FE. Changes in local wall thickness correlate with pathologic lesion size following radiofrequency catheter ablation: an intracardiac echocardiographic imaging study. Echocardiography. 2001;18:503–7. DOI
Schwartzman D, Ren JF, Devine WA, Callans DJ. Cardiac swelling associated with linear radiofrequency ablation in the atrium. J Interv Card Electrophysiol. 2001;5:159–66. DOI
Wright M, Harks E, Deladi S, Fokkenrood S, Brink R, Belt H, et al. Characteristics of radiofrequency catheter ablation lesion formation in real time in vivo using near field ultrasound imaging. JACC Clin Electrophysiol. 2018;4:1062–72. DOI
Havranek S, Alfredova H, Fingrova Z, Souckova L, Wichterle D. Early and delayed alteration of atrial electrograms around single radiofrequency ablation lesion. Front Cardiovasc Med. 2019;5:190. DOI
ClinicalTrials.gov
NCT03332862