The use of extracorporeal membrane oxygenation (ECMO) has recently increased exponentially. ECMO has become the preferred mode of organ support in refractory respiratory or circulatory failure. The fragile balance of haemostasis physiology is massively altered by the patient's critical condition and specifically the aetiology of the underlying disease. Furthermore, an application of ECMO conveys another disturbance of haemostasis due to blood-circuit interaction and the presence of an oxygenator. The purpose of this review is to summarise current knowledge on the anticoagulation management in patients undergoing ECMO therapy. The unfractionated heparin modality with monitoring of activated partial thromboplastin tests is considered to be a gold standard for anticoagulation in this specific subgroup of intensive care patients. However, alternative modalities with other agents are comprehensively discussed. Furthermore, other ways of monitoring can represent the actual state of coagulation in a more complex fashion, such as thromboelastometric/graphic methods, and might become more frequent. In conclusion, the coagulation system of patients with ECMO is altered by multiple variables, and there is a significant lack of evidence in this area. Therefore, a highly individualised approach is the best solution today.
- Publikační typ
- časopisecké články MeSH
- přehledy MeSH
PURPOSE: The objective of our study was to evaluate the diagnostic accuracy of internal jugular vein (IJV) collapsibility as a predictor of fluid responsiveness in spontaneously breathing patients after cardiac surgery. METHODS: In this prospective observational study, spontaneously breathing patients were enrolled on the first postoperative day after coronary artery bypass grafting. Hemodynamic data coupled with simultaneous ultrasound assessment of the IJV were collected at baseline and after passive leg raising test (PLR). Continuous cardiac index (CI), stroke volume (SV), and stroke volume variation (SVV) were assessed with FloTracTM/EV1000TM. Fluid responsiveness was defined as an increase in CI ≥ 10% after PLR. We compared the differences in measured variables between fluid responders and non-responders and tested the ability of ultrasonographic IJV indices to predict fluid responsiveness. RESULTS: Fifty-four patients were included in the study. Seventeen (31.5%) were fluid responders. The responders demonstrated significantly lower inspiratory and expiratory diameters of the IJV at baseline, but IJV collapsibility was comparable (P = 0.7). Using the cut-off point of 20%, IJV collapsibility predicted fluid responsiveness with a sensitivity of 76.5% and specificity of 38.9%, ROC AUC 0.55. CONCLUSION: In spontaneously breathing patients after surgical coronary revascularisation, collapsibility of the internal jugular vein did not predict fluid responsiveness.
- MeSH
- dýchání MeSH
- hemodynamika MeSH
- kardiochirurgické výkony * MeSH
- lidé MeSH
- tekutinová terapie MeSH
- tepový objem MeSH
- venae jugulares * MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
- pozorovací studie MeSH
- práce podpořená grantem MeSH
End-expiratory occlusion (EEO) and end-inspiratory occlusion (EIO) tests have been successfully used to predict fluid responsiveness in various settings using calibrated pulse contour analysis and echocardiography. The aim of this study was to test if respiratory occlusion tests predicted fluid responsiveness reliably in cardiac surgical patients with protective ventilation. This single-centre, prospective study, included 57 ventilated patients after elective coronary artery bypass grafting who were indicated for fluid expansion. Baseline echocardiographic measurements were obtained and patients with significant cardiac pathology were excluded. Cardiac index (CI), stroke volume and stroke volume variation were recorded using uncalibrated pulse contour analysis at baseline, after performing EEO and EIO tests and after volume expansion (7 mL/kg of succinylated gelatin). Fluid responsiveness was defined as an increase in cardiac index by 15%. Neither EEO, EIO nor their combination predicted fluid responsiveness reliably in our study. After a combined EEO and EIO, a cut-off point for CI change of 16.7% predicted fluid responsiveness with a sensitivity of 61.8%, specificity of 69.6% and ROC AUC of 0.593. In elective cardiac surgical patients with protective ventilation, respiratory occlusion tests failed to predict fluid responsiveness using uncalibrated pulse contour analysis.
- Publikační typ
- časopisecké články MeSH
In patients with acute circulatory failure, fluid administration represents a first-line therapeutic intervention for improving cardiac output. However, only approximately 50% of patients respond to fluid infusion with a significant increase in cardiac output, defined as fluid responsiveness. Additionally, excessive volume expansion and associated hyperhydration have been shown to increase morbidity and mortality in critically ill patients. Thus, except for cases of obvious hypovolaemia, fluid responsiveness should be routinely tested prior to fluid administration. Static markers of cardiac preload, such as central venous pressure or pulmonary artery wedge pressure, have been shown to be poor predictors of fluid responsiveness despite their widespread use to guide fluid therapy. Dynamic tests including parameters of aortic blood flow or respiratory variability of inferior vena cava diameter provide much higher diagnostic accuracy. Nevertheless, they are also burdened with several significant limitations, reducing the reliability, or even precluding their use in many clinical scenarios. This non-systematic narrative review aims to provide an update on the novel, less employed dynamic tests of fluid responsiveness evaluation in critically ill patients.
- Publikační typ
- časopisecké články MeSH
- přehledy MeSH
The review article is focused on developments in optical devices, other than laryngoscopes, in airway management and tracheal intubation. It brings information on advantages and limitations in their use, compares different devices, and summarizes benefits in various clinical settings. Supraglottic airway devices may be used as a conduit for fiberscope-guided tracheal intubation mainly as a rescue plan in the scenario of difficult or failed laryngoscopy. Some of these devices offer the possibility of direct endotracheal tube placement. Hybrid devices combine the features of two different intubating tools. Rigid and semi-rigid optical stylets represent another option in airway management. They offer benefits in restricted mouth opening and may be used also for retromolar intubation. Awake flexible fiberoptic intubation has been a gold standard in predicted difficult laryngoscopy for decades. Modern flexible bronchoscopes used in anesthesia and intensive care are disposable devices and contain optical lenses instead of fibers. Endotracheal tubes with an incorporated optics are used mainly in thoracic anesthesia for lung separation. They are available in double-lumen and single-lumen versions. They offer a benefit of direct view to the carina and do not require flexible fiberscope for their correct placement.
- Publikační typ
- časopisecké články MeSH
- přehledy MeSH
Videolaryngoscopes may reduce cervical spine movement during tracheal intubation in patients with neck trauma. This manikin study aimed to compare the performance of disposable non-channeled and channeled blades of the King Vision™ videolaryngoscope in simulated cervical spine injury. Fifty-eight anesthesiologists in training intubated the TruMan manikin with the neck immobilized using each blade in a randomized order. The primary outcome was the time needed for tracheal intubation, secondary aims included total success rate, the time required for visualization of the larynx, number of attempts, view of the vocal cords, and subjective assessment of both methods. Intubation time with the channeled blade was shorter, with a median time of 13 s (IQR 9-19) vs. 23 s (14.5-37.5), p < 0.001, while times to visualization of the larynx were similar in both groups (p = 0.54). Success rates were similar in both groups, but intubation with the non-channeled blade required more attempts (1.52 vs. 1.05; p < 0.001). The participants scored the intubation features of the channeled blade significantly higher, while visualization features were scored similarly in both groups. Both blades of the King Vision™ videolaryngoscope are reliable intubation devices in a simulated cervical spine injury in a manikin model when inserted by non-experienced operators. The channeled blade allowed faster intubation of the trachea.
- Publikační typ
- časopisecké články MeSH