BACKGROUND: The first dual-chamber leadless pacemaker (DC-LP) system consists of 2 separate atrial and ventricular devices that communicate to maintain synchronous atrioventricular pacing and sensing. The initial safety and efficacy were previously reported. OBJECTIVE: The purpose of this study was to evaluate the chronic electrical performance of the DC-LP system. METHODS: Patients meeting standard dual-chamber pacing indications were enrolled and implanted with the DC-LP system (Aveir DR, Abbott), including right atrial and ventricular helix-fixation LPs (atrial leadless pacemaker [ALP], ventricular leadless pacemaker [VLP]). Pacing capture threshold, sensed amplitude, and pacing impedance were collected using the device programmer at prespecified timepoints from 0-6 months postimplant. RESULTS: De novo devices were successfully implanted in 381 patients with complete 6-month data (62% male; age 69 ± 14 years; weight 82 ± 20 kg; 65% sinus nodal dysfunction, 30% atrioventricular block). ALPs were implanted predominantly in the right atrial appendage anterior base and VLPs primarily at the mid-to-apical right ventricular septum. From implant to 1 month, pacing capture thresholds (0.4-ms pulse width) improved in both ALPs (2.4 ± 1.5 V to 0.8 ± 0.8 V; P <.001) and VLPs (0.8 ± 0.6 V to 0.6 ± 0.4 V; P <.001). Sensed amplitudes improved in both ALPs (1.8 ± 1.3 mV to 3.4 ± 1.9 mV; P <.001) and VLPs (8.8 ± 4.0 mV to 11.7 ± 4.2 mV; P <.001). Impedances were stable in ALPs (334 ± 68 Ω to 329 ± 52 Ω; P = .17) and reduced in VLPs (789 ± 351 Ω to 646 ± 190 Ω; P <.001). Electrical measurements remained relatively stable from 1-6 months postimplant. No differences in electrical metrics were observed among ALP or VLP implant locations. CONCLUSION: This first in-human evaluation of the new dual-chamber leadless pacemaker system demonstrated reliable electrical performance throughout the initial 6-month evaluation period.
- MeSH
- atrioventrikulární blokáda terapie patofyziologie MeSH
- časové faktory MeSH
- design vybavení * MeSH
- kardiostimulace umělá * metody MeSH
- kardiostimulátor * MeSH
- lidé MeSH
- následné studie MeSH
- senioři MeSH
- srdeční komory patofyziologie MeSH
- syndrom chorého sinu terapie patofyziologie MeSH
- výsledek terapie MeSH
- Check Tag
- lidé MeSH
- mužské pohlaví MeSH
- senioři MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
BACKGROUND: An increasing number of patients with heart failure receive implantable cardioverter-defibrillators (ICDs) or cardiac resynchronisation defibrillators (CRT-Ds) with telemonitoring function. Early detection of worsening heart failure, or upstream factors predisposing to worsening heart failure, by implant-based telemonitoring might enable pre-emptive intervention and improve outcomes, but the evidence is weak. We investigated this possibility in IN-TIME, a clinical trial. METHODS: We did this randomised, controlled trial at 36 tertiary clinical centres and hospitals in Australia, Europe, and Israel. We enrolled patients with chronic heart failure, NYHA class II-III symptoms, ejection fraction of no more than 35%, optimal drug treatment, no permanent atrial fibrillation, and a recent dual-chamber ICD or CRT-D implantation. After a 1 month run-in phase, patients were randomly assigned (1:1) to either automatic, daily, implant-based, multiparameter telemonitoring in addition to standard care or standard care without telemonitoring. Investigators were not masked to treatment allocation. Patients were masked to allocation unless they were contacted because of telemonitoring findings. Follow-up was 1 year. The primary outcome measure was a composite clinical score combining all-cause death, overnight hospital admission for heart failure, change in NYHA class, and change in patient global self-assessment, for the intention-to-treat population. The trial is registered with ClinicalTrials.gov, number NCT00538356. FINDINGS: We enrolled 716 patients, of whom 664 were randomly assigned (333 to telemonitoring, 331 to control). Mean age was 65·5 years and mean ejection fraction was 26%. 285 (43%) of patients had NYHA functional class II and 378 (57%) had NYHA class III. Most patients received CRT-Ds (390; 58·7%). At 1 year, 63 (18·9%) of 333 patients in the telemonitoring group versus 90 (27·2%) of 331 in the control group (p=0·013) had worsened composite score (odds ratio 0·63, 95% CI 0·43-0·90). Ten versus 27 patients died during follow-up. INTERPRETATION: Automatic, daily, implant-based, multiparameter telemonitoring can significantly improve clinical outcomes for patients with heart failure. Such telemonitoring is feasible and should be used in clinical practice. FUNDING: Biotronik SE & Co. KG.
- MeSH
- ambulantní monitorování přístrojové vybavení MeSH
- defibrilátory implantabilní * MeSH
- lidé MeSH
- senioři MeSH
- srdeční selhání patofyziologie terapie MeSH
- telemedicína metody MeSH
- výsledek terapie MeSH
- Check Tag
- lidé MeSH
- mužské pohlaví MeSH
- senioři MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- multicentrická studie MeSH
- práce podpořená grantem MeSH
- randomizované kontrolované studie MeSH
- Geografické názvy
- Austrálie MeSH
- Evropa MeSH
- Izrael MeSH