Various combinations of PEG-silica, phenyl-silica and C18 columns in a single-column or serial (tandem) arrangement in the first dimension and a monolithic Chromolith column in the second dimension were tested for comprehensive two-dimensional (2D) LCxLC separation of phenolic and flavone natural antioxidants. The combinations of different stationary phase chemistries provided low selectivity correlations between the first-dimension and the second-dimension separation systems. Improvement in system orthogonality, bandwidths suppression, more regular band distribution over the whole 2D retention plane and increased peak capacity in different 2D setups was achieved by using gradients with matching profiles running in parallel in the two dimensions over the whole 2D separation time range. Instead of two sampling loops, two alternating trapping XTerra columns were used for sample fraction transfer from the first-dimension column to the second dimension. Stronger retention on the XTerra columns in comparison to PEG-silica or phenyl-silica columns in the first dimension allowed using focusing of sample fractions in narrow zones on the top of a trapping column and back-flushing into the second dimension in a very low volume of the mobile phase. This fraction transfer modulation provided significant bandwidth suppression in the second dimension. 2D systems with optimized stationary phase selectivity, parallel gradients and fraction transfer modulation using two trapping columns were applied for the analysis of natural antioxidants in beer and wine samples.
The separation selectivity of octadecyl-silica (C18) and of bonded pentafluorophenylpropyl-silica (F5) and PEG-silica columns was compared for natural phenolic antioxidants. The separation selectivities for phenolic antioxidants on C18 and F5 columns are strongly correlated, but low selectivity correlation indicating strong differences in the retention mechanism was observed between the C18 and PEG columns. Hence, the combination of a C18 and a PEG column is useful for separation of phenolic antioxidants that are not fully separated on single columns. Two-dimensional comprehensive liquid chromatography using a short PEG-silica column in the first dimension and a conventional C18-silica in the second dimension has the advantage of on-column focusing of the fractions transferred onto the C18 column in the second dimension, as a weaker mobile phase is used in the first dimension than in the second dimension. However, a stop-flow set-up in the first dimension system is necessary after the transfer of each fraction to the second dimension. Peak capacity is considerably larger but the separation time is much longer than with serially coupled PEG and C18 columns, which were employed for separation of beer and hop extract samples in connection with coulometric detection.
- MeSH
- Antioxidants analysis MeSH
- Phenols analysis MeSH
- Financing, Organized MeSH
- Humans MeSH
- Silicon Dioxide chemistry MeSH
- Polyethylene Glycols chemistry MeSH
- Plant Extracts chemistry MeSH
- Chromatography, High Pressure Liquid methods instrumentation MeSH
- Check Tag
- Humans MeSH
- Publication type
- Evaluation Study MeSH