OBJECTIVES: Mitral regurgitation (MR) is frequently observed in patients undergoing left ventricular assist device implantation. We investigated the impact of preoperative MR on left ventricular assist device patients. METHODS: A retrospective propensity score-matched analysis of adult patients enrolled in the EUROMACS registry between 1 January 2011 and 30 November 2021 was performed. Patients were divided into 2 groups according to the grade of preoperative MR: none-to-mild (MR 0-II) or moderate-to-severe (MR III-IV). RESULTS: Following 1:1 propensity score matching, each group consisted of 914 patients. Incidence of postoperative temporary right ventricular support, reoperation for bleeding and dialysis was similar. MR III-IV demonstrated shorter median intensive care unit stay [14 days (6; 27.8) vs 10 days (5; 22), P = 0.004] and ventilation time [72 h (22, 320) vs 31 h (18, 150), P < 0.001]. Mortality was lower for MR III-IV patients [subdistribution hazard ratio: 0.66, 95% confidence interval (CI): 0.59-0.73, P < 0.001]. The 1-year survival was 68.1% (95% CI: 65.1-71.3%) in MR 0-II and 75% (95% CI: 72.1-78%) in MR III-IV. A lower incidence of total complications [odds ratio (OR): 0.93 (0.89-0.98), P = 0.003] and trend towards a lower risk of neurological dysfunction (subdistribution hazard ratio: 0.79; 95% CI: 0.61-1.01, P = 0.063) and sustained ventricular tachycardia [OR: 0.93 (0.54-1.03), P = 0.074] were demonstrated for MR III-IV. The risk of fatal stroke and pump thrombosis was similar. CONCLUSIONS: Moderate-to-severe MR in patients undergoing left ventricular assist device implantation is associated with better mid-term survival and lower incidence of total major adverse events and complications. The incidence of severe postoperative complications including fatal stroke and device thrombosis was similar.
OBJECTIVES: A third paediatric report has been generated from the European Registry for Patients with Mechanical Circulatory Support (EUROMACS). The purpose of EUROMACS, which is operated by the European Association for Cardio-Thoracic Surgery, is to gather data related to durable mechanical circulatory support for scientific purposes and to publish reports with respect to the course of mechanical circulatory support therapy. Since the first report issued, efforts to increase compliance and participation have been extended. Additionally, the data provided the opportunity to analyse patients of younger age and lower weight. METHODS: Participating hospitals contributed pre-, peri- and long-term postoperative data on mechanical circulatory support implants to the registry. Data for all implants in paediatric patients (<19 years of age) performed from 1 January 2000 to 31 December 2020 were analysed. This report includes updates of patient characteristics, implant frequency, outcome (including mortality rates, transplants and recovery rates) as well as adverse events including neurological dysfunction, device malfunction, major infection and bleeding. RESULTS: Twenty-five hospitals contributed 537 registered implants in 480 patients. The most frequent aetiology of heart failure was any form of cardiomyopathy (59%), followed by congenital heart disease and myocarditis (15% and 14%, respectively). Competing outcomes analysis revealed that a total of 86% survived to transplant or recovery or are ongoing; at the 2-year follow-up examination, 21.9% died while on support. At 12 months, 45.1% received transplants, 7.5% were weaned from their device and 20.8% died. The 3-month adverse events rate was 1.59 per patient-year for device malfunction including pump exchange, 0.7 for major bleeding, 0.78 for major infection and 0.71 for neurological events. CONCLUSIONS: The overall survival rate was 79.2% at 12 months following ventricular assist device implant. The comparison of survival rates of the early and later eras shows no significant difference. A focus on specific subgroups showed that survival was less in patients of younger age (<1 year of age; P = 0.01) and lower weight (<20 kg; P = 0.015). Transplant rates at 6 months continue to be low (33.2%).
- MeSH
- dítě MeSH
- hrudní chirurgické výkony * MeSH
- lidé MeSH
- podpůrné srdeční systémy * škodlivé účinky MeSH
- registrace MeSH
- retrospektivní studie MeSH
- srdeční selhání * epidemiologie etiologie chirurgie MeSH
- vrozené srdeční vady * epidemiologie chirurgie MeSH
- výsledek terapie MeSH
- Check Tag
- dítě MeSH
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
OBJECTIVES: In the third report of the European Registry for Patients with Mechanical Circulatory Support of the European Association for Cardio-Thoracic Surgery, outcomes of patients receiving mechanical circulatory support are reviewed in relation to implant era. METHODS: Procedures in adult patients (January 2011-June 2020) were included. Patients from centres with <60% follow-ups completed were excluded. Outcomes were stratified into 3 eras (2011-2013, 2014-2017 and 2018-2020). Adverse event rates (AERs) were calculated and stratified into early phase (<3 months) and late phase (>3 months). Risk factors for death were explored using univariable Cox regression with a stepwise time-varying hazard ratio (<3 vs >3 months). RESULTS: In total, 4834 procedures in 4486 individual patients (72 hospitals) were included, with a median follow-up of 1.1 (interquartile range: 0.3-2.6) years. The annual number of implants (range: 346-600) did not significantly change (P = 0.41). Both Interagency Registry for Mechanically Assisted Circulatory Support class (classes 4-7: 23, 25 and 33%; P < 0.001) and in-hospital deaths (18.5, 17.2 and 11.2; P < 0.001) decreased significantly between eras. Overall, mortality, transplants and the probability of weaning were 55, 25 and 2% at 5 years after the implant, respectively. Major infections were mainly noted early after the implant occurred (AER<3 months: 1.44 vs AER>3 months: 0.45). Bilirubin and creatinine levels were significant risk factors in the early phase but not in the late phase after the implant. CONCLUSIONS: In its 10 years of existence, EUROMACS has become a point of reference enabling benchmarking and outcome monitoring. Patient characteristics and outcomes changed between implant eras. In addition, both occurrence of outcomes and risk factor weights are time dependent.
OBJECTIVES: In patients supported by a durable left ventricular assist device (LVAD), infections are a frequently reported adverse event with increased morbidity and mortality. The purpose of this study was to investigate the possible association between infections and thromboembolic events, most notable cerebrovascular accidents (CVAs), in LVAD patients. METHODS: An analysis of the multicentre European Registry for Patients Assisted with Mechanical Circulatory Support was performed. Infections were categorized as VAD-specific infections, VAD-related infections and non-VAD-related infections. An extended Kaplan-Meier analysis for the risk of CVA with infection as a time-dependent covariate and a multivariable Cox proportional hazard model were performed. RESULTS: For this analysis, 3282 patients with an LVAD were included with the majority of patients being male (83.1%). During follow-up, 1262 patients suffered from infection, and 457 patients had a CVA. Cox regression analysis with first infection as time-dependent covariate revealed a hazard ratio (HR) for CVA of 1.90 [95% confidence interval (CI): 1.55-2.33; P < 0.001]. Multivariable analysis confirmed the association for infection and CVAs with an HR of 1.99 (95% CI: 1.62-2.45; P < 0.001). With infections subcategorized, VAD-specific HR was 1.56 (95% CI: 1.18-2.08; P 0.002) and VAD-related infections [HR: 1.99 (95% CI: 1.41-2.82; P < 0.001)] remained associated with CVAs, while non-VAD-related infections (P = 0.102) were not. CONCLUSIONS: Infection during LVAD support is associated with an increased risk of developing an ischaemic or haemorrhagic CVA, particularly in the setting of VAD-related or VAD-specific infections. This suggests the need of a stringent anticoagulation management and adequate antibiotic treatment during an infection in LVAD-supported patients.
- MeSH
- antibakteriální látky MeSH
- antikoagulancia MeSH
- cévní mozková příhoda * epidemiologie etiologie MeSH
- lidé MeSH
- podpůrné srdeční systémy * škodlivé účinky MeSH
- registrace MeSH
- retrospektivní studie MeSH
- srdeční selhání * MeSH
- výsledek terapie MeSH
- Check Tag
- lidé MeSH
- mužské pohlaví MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH