We report the first amperometric method for the simultaneous determination of tert-butylhydroquinone (tBHQ), propyl gallate (PG), and butylated hydroxyanisole (BHA) using flow injection analysis coupled to multiple-pulse amperometry. A sequence of potential pulses was selected in order to detect tBHQ, PG, and BHA separately in a single injection step at a glassy carbon electrode without the need of a preliminary separation. A mixture of methanol and 0.040M Britton-Robinson buffer was used both as a carrier solution and for dilution of analyzed solutions before injection. The method is precise (RSD < 5%, n = 10), fast (a frequency of 140 injections h-1), provides sufficiently low quantification limits (2.51, 1.45, and 0.85μmolL-1 for tBHQ, PG, and BHA, respectively) and can be easily applied without high demands on instrumentation. As a practical application, the determination of these antioxidants contained in commercial chewing gum samples was carried out by applying a simple extraction procedure.
The carbon fiber and silver microwire were used as working and pseudoreference electrode, respectively, and inserted into the ending of capillary to prepare monolithic capillary column with an integrated electrochemical detector. Prepared capillary devices offered stable and robust results with relative standard deviations of retention, resolution, and detection signal lower than 1.5, 5.5, and 5.0%, respectively. To further increase sensitivity of developed electrochemical microdetector, multiple pulse amperometry detection mode has been used. Optimized integrated device provided reliable chromatographic separation of mixture of neurotransmitters with calibration curve for dopamine linear from 0.5 to 20.0mgL-1 and an instrumental limit of detection as low as 24pg of injected dopamine. Finally, developed capillary column was applied to successful determination of dopamine in a human urine. By using both calibration curve and standard addition method, the dopamine level was determined to be 0.74±0.03mgL-1 and 0.71±0.02mgL-1, respectively. Triplicates of dopamine analysis provided relative standard deviations lower than 2.7% for intraday analyses, while interday relative standard deviations were lower than 3.6% for five consecutive days.
- MeSH
- Dopamine analysis MeSH
- Electrochemical Techniques instrumentation methods MeSH
- Electrodes MeSH
- Humans MeSH
- Neurotransmitter Agents analysis MeSH
- Check Tag
- Humans MeSH
- Publication type
- Journal Article MeSH
- Evaluation Study MeSH