Strzelczyk, Adam*
Dotaz
Zobrazit nápovědu
- MeSH
- epilepsie * MeSH
- lidé MeSH
- záchvaty * MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
- komentáře MeSH
Over the last few decades the ILAE classifications for seizures and epilepsies (ILAE-EC) have been updated repeatedly to reflect the substantial progress that has been made in diagnosis and understanding of the etiology of epilepsies and seizures and to correct some of the shortcomings of the terminology used by the original taxonomy from the 1980s. However, these proposals have not been universally accepted or used in routine clinical practice. During the same period, a separate classification known as the "Four-dimensional epilepsy classification" (4D-EC) was developed which includes a seizure classification based exclusively on ictal symptomatology, which has been tested and adapted over the years. The extensive arguments for and against these two classification systems made in the past have mainly focused on the shortcomings of each system, presuming that they are incompatible. As a further more detailed discussion of the differences seemed relatively unproductive, we here review and assess the concordance between these two approaches that has evolved over time, to consider whether a classification incorporating the best aspects of the two approaches is feasible. To facilitate further discussion in this direction we outline a concrete proposal showing how such a compromise could be accomplished, the "Integrated Epilepsy Classification". This consists of five categories derived to different degrees from both of the classification systems: 1) a "Headline" summarizing localization and etiology for the less specialized users, 2) "Seizure type(s)", 3) "Epilepsy type" (focal, generalized or unknown allowing to add the epilepsy syndrome if available), 4) "Etiology", and 5) "Comorbidities & patient preferences".
- MeSH
- epilepsie klasifikace MeSH
- lidé MeSH
- směrnice pro lékařskou praxi jako téma * MeSH
- společnosti lékařské * MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
- přehledy MeSH
Given its non-invasive nature, there is increasing interest in the use of transcutaneous vagus nerve stimulation (tVNS) across basic, translational and clinical research. Contemporaneously, tVNS can be achieved by stimulating either the auricular branch or the cervical bundle of the vagus nerve, referred to as transcutaneous auricular vagus nerve stimulation(VNS) and transcutaneous cervical VNS, respectively. In order to advance the field in a systematic manner, studies using these technologies need to adequately report sufficient methodological detail to enable comparison of results between studies, replication of studies, as well as enhancing study participant safety. We systematically reviewed the existing tVNS literature to evaluate current reporting practices. Based on this review, and consensus among participating authors, we propose a set of minimal reporting items to guide future tVNS studies. The suggested items address specific technical aspects of the device and stimulation parameters. We also cover general recommendations including inclusion and exclusion criteria for participants, outcome parameters and the detailed reporting of side effects. Furthermore, we review strategies used to identify the optimal stimulation parameters for a given research setting and summarize ongoing developments in animal research with potential implications for the application of tVNS in humans. Finally, we discuss the potential of tVNS in future research as well as the associated challenges across several disciplines in research and clinical practice.
- Publikační typ
- časopisecké články MeSH
- přehledy MeSH