The process of choosing the most proper technique for studying the molecular interactions is based on critical factors such as instrumentation complexity, automation, experimental procedures, analysis time, consumables, and cost-value. This review has tracked the use of affinity capillary electrophoresis (ACE) and microscale thermophoresis (MST) techniques in the evaluation of molecular binding among different molecules during the 5 years 2016-2021. ACE has proved to be an attractive technique for biomolecular characterization with high resolution efficiency where small variations in several controlling factors can much improve such efficiency compared to other analytical techniques. Meanwhile, MST has proved its higher sensitivity for smaller amounts of complex non-purified biosamples without affecting its robustness while providing high through output. However, the main motivation to review both techniques in the proposed review was their capability to carry out all experiments without the need for immobilizing one interacting partner, besides a great flexibility in the use of buffering systems. The proposed review demonstrates the importance of both techniques in different areas of life sciences. Moreover, the recent advances in exploiting ACE and MST in other research interests have been discussed.
- MeSH
- elektroforéza kapilární * metody MeSH
- vazba proteinů MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH
- přehledy MeSH
In 1961, Svensson described isoelectric focusing (IEF), the separation of ampholytic compounds in a stationary, natural pH gradient that was formed by passing current through a sucrose density gradient-stabilized ampholyte mixture in a constant cross-section apparatus, free of mixing. Stable pH gradients were formed as the electrophoretic transport built up a series of isoelectric ampholyte zones-the concentration of which decreased with their distance from the electrodes-and a diffusive flux which balanced the generating electrophoretic flux. When polyacrylamide gel replaced the sucrose density gradient as the stabilizing medium, the spatial and temporal stability of Svensson's pH gradient became lost, igniting a search for the explanation and mitigation of the loss. Over time, through a series of insightful suggestions, the currently held notion emerged that in the modern IEF experiment-where the carrier ampholyte (CA) mixture is placed between the anolyte- and catholyte-containing large-volume electrode vessels (open-system IEF)-a two-stage process operates that comprises a rapid first phase during which a linear pH gradient develops, and a subsequent slow, second stage, during which the pH gradient decays as isotachophoretic processes move the extreme pI CAs into the electrode vessels. Here we trace the development of the two-stage IEF model using quotes from the original publications and point out critical results that the IEF community should have embraced but missed. This manuscript sets the foundation for the companion papers, Parts 2 and 3, in which an alternative model, transient bidirectional isotachophoresis is presented to describe the open-system IEF experiment.
The carrier ampholytes-based (CA-based) isoelectric focusing (IEF) experiment evolved from Svensson's closed system IEF (constant spatial current density, absence of convective mixing, counter-balancing electrophoretic and diffusive fluxes yielding a steady state pH gradient) to the contemporary open system IEF (absence of convective mixing, large cross-sectional area electrode vessels, lack of counter-balancing electrophoretic- and diffusive fluxes leading to transient pH gradients). Open system IEF currently is described by a two-stage model: In the first stage, a rapid IEF process forms the pH gradient which, in the second stage, is slowly degraded by isotachophoretic processes that move the most acidic and most basic CAs into the electrode vessels. An analysis of the effective mobilities and the effective mobility to conductivity ratios of the anolyte, catholyte, and the CAs indicates that in open system IEF experiments a single process, transient bidirectional isotachophoresis (tbdITP) operates from the moment current is turned on until it is turned off. In tbdITP, the anolyte and catholyte provide the leading ions and the pI 7 CA or the reactive boundary of the counter-migrating H3 O+ and OH- ions serves as the shared terminator. The outcome of the tbdITP process is determined by the ionic mobilities, pKa values, and loaded amounts of all ionic and ionizable components: It is constrained by both the transmitted amount of charge and the migration space available for the leading ions. tbdITP and the resulting pH gradient can never reach steady state with respect to the spatial coordinate of the separation channel.
In modern isoelectric focusing (IEF) systems, where (i) convective mixing is prevented by gels or small cross-sectional area separation channels, (ii) current densities vary spatially due to the presence of electrode vessels with much larger cross-sectional areas than those of the gels or separation channels, and (iii) electrophoretic and diffusive fluxes do not balance each other, stationary, steady-state pH gradients cannot form (open-system IEF). Open-system IEF is currently described as a two-stage process: A rapid IEF process forms the pH gradient from the carrier ampholytes (CAs) in the first stage, then isotachophoretic processes degrade the pH gradient in the second stage as the extreme pI CAs are moved into the electrode vessels where they become diluted. Based on the ratios of the local effective mobilities and the local conductivities ( μLeff(x)$\mu _{\rm{L}}^{{\rm{eff}}}( x )$ / κ(x)$\kappa ( x )$ values) of the anolyte, catholyte, and the CAs, we pointed out in the preceding paper (Vigh G, Gas B, Electrophoresis 2023, 44, 675-88) that in open-system IEF, a single process, transient, bidirectional isotachophoresis (tbdITP) operates from the moment current is turned on. In this paper, we demonstrate some of the operational features of the tbdITP model using the new ITP/IEF version of Simul 6.
Nonaqueous capillary electrophoresis (NACE) using methanol (MeOH) as a solvent of the BGEs and quantum mechanical density functional theory (DFT) have been applied to determine the thermodynamic acidity (ionization) constants (pKa ) of mono- and diaza[5]helicenes, mono- and diaza[6]helicenes, and their dibenzo derivatives in MeOH and water. First, the mixed acidity constants, pKa,MeOHmix${\rm{p}}K_{{\rm{a,MeOH}}}^{{\rm{mix}}}$ , of ionogenic pyridinium groups of azahelicenes and their derivatives in MeOH were obtained by nonlinear regression analysis of pH dependence of their effective electrophoretic mobilities. The effective mobilities were measured by NACE in a large series of methanolic BGEs within a wide conventional pH range (pHMeOH 1.6-12.0) and at ambient temperature (21-26°C) in a home-made CE device. Prior to mixed acidity constant calculation, the effective mobilities were corrected to reference temperature (25°C) and constant ionic strength (25 mM). Then, the mixed acidity constants were recalculated to the thermodynamic acidity constants pKa,MeOH by the Debye-Hückel theory of nonideality of electrolyte solutions. Finally, from the methanolic thermodynamic pKa,MeOH values, the aqueous thermodynamic pKa,H2O${\rm{p}}{K_{{\rm{a,}}{{\rm{H}}_{\rm{2}}}{\rm{O}}}}$ constants were estimated using the empirical relations between methanolic and aqueous acidity constants derived for structurally related pyridine derivatives. Depending on the number and position of the nitrogen atoms in their molecules, the analyzed azahelicenes were found to be weak to moderate bases with methanolic pKa,MeOH in the range 2.01-8.75 and with aqueous pKa,H2O${\rm{p}}{K_{{\rm{a,}}{{\rm{H}}_{\rm{2}}}{\rm{O}}}}$ in the range 1.67-8.28. The thermodynamic pKa,MeOH obtained by the DFT calculations were in a good agreement with those determined experimentally by NACE.
Monitoring metabolite uptake and excretion in the culture medium is a noninvasive technique that is used for the metabolic study of cleaving embryos after in vitro fertilization. Low sample consumption, the versatility of the detection, and optimal sensitivity and selectivity are essential elements for extracellular metabolome analyses, and can be conveniently achieved by combining CE with mass spectrometric detection. This paper reports a method for amino acid determination in a limited volume sample (8 μL) of spent culture media collected after the cultivation of in vitro fertilized embryos. Special attention was focused on the sample preparation procedure. The sample was processed with acetonitrile, which facilitates online sample preconcentration via field-amplified sample stacking, and undesired sample evaporation was significantly reduced by the simultaneous addition of dimethyl sulfoxide. Key parameters that affected electrophoretic separation and mass spectrometric detection were investigated, including the type of buffers and organic solvent, optimization of their concentrations, and finally the settings for their ionization. The separation and quantification of 19 amino acids were achieved using 15% acetic acid as the background electrolyte with a sheath liquid consisting of an equimolar mixture of methanol and water. The applicability of the optimized system was demonstrated by determining the amino acid profile in 40 samples of spent cultivation medium in this pilot study. This developed method also has great potential for amino acid analyses in minute sample volumes of other biological matrices.
CE method for the baseline separation of structurally similar flavonolignans silybin A, silybin B, isosilybin A, isosilybin B, silychristin, silydianin, and their precursor taxifolin in silymarin complex has been developed and validated. The optimized background electrolyte was 100 mmol/L boric acid (pH 9.0) containing 5 mmol/L heptakis(2,3,6-tri-O-methyl)-β-CD and 10% (v/v) of methanol. The separation was carried out in an 80.5/72 cm (50 μm id) fused silica capillary at +25 kV with UV detection at 200 nm. Genistein (10 μg/mL) was used as internal standard. The resolution between the diastereomers of silybin and isosilybin was 1.73 and 2.59, respectively. The method was validated for each analyte in a concentration range of 2.5-50 μg/mL. The calibration curves were rectilinear with correlation coefficients ≥0.9972. The method was applied to determine flavonolignans in two dietary supplements containing Silybum marianum extract. The accuracy was evaluated by comparing the results of the CE analyses of the dietary supplements with those of the reference United States Pharmacopeial HPLC method. The unpaired t-test did not show a statistically significant difference between the results of both the proposed CE and the reference method (p > 0.05, n = 3).
There is an increasing interest in acoustics for microfluidic applications. This field, commonly known as acoustofluidics involves the interaction of ultrasonic standing waves with fluids and dispersed microparticles. The combination of microfluidics and the so-called acoustic standing waves (ASWs) led to the development of integrated systems for contact-less on-chip cell and particle manipulation where it is possible to move and spatially localize these particles based on the different acoustophysical properties. While it was initially suggested that the acoustic forces could be harmful to the cells and could impact cell viability, proliferation, or function via phenotypic or even genotypic changes, further studies disproved such claims. This review is summarizing some interesting applications of acoustofluidics in the manipulations of biomaterials, such as cells or subcellular vesicles, in works published mainly within the last 5 years.
We present a method for finely adjustable electroosmotic flow (EOF) velocity in cathodic direction for the optimization of separations in capillary electrophoresis. To this end, we use surface modification of the separation fused silica capillary by the covalently attached copolymer of acrylamide (AM) and 2-acrylamido-2-methyl-1-propanesulfonate (AMPS), that is, poly(AM-co-AMPS) or PAMAMPS. Coatings were formed by the in-capillary polymerization of a mixture of the neutral AM and anionic AMPS monomers premixed in various ratios in order to control the charge density of the copolymer. EOF mobility varies in the 0 to ∼40 × 10-9 m2 V-1 s-1 interval for PAMAMPS coatings ranging from 0 to 60 mol.% of charged AMPS monomer. For EOF in PAMAMPS-treated capillaries, we observed (i) a negligible dependence on pH in the 2-10 interval, (ii) a minor variance among background electrolytes (BGEs) in function of their components and (iii) its standard decrease with increasing ionic strength of the BGE. Interest in variable cathodic EOF was demonstrated by the amelioration of separation of two kinds of isomeric anionic analytes, that is, monosaccharides phosphates and helquat enantiomers, in counter-EOF mode.
Saccharides form one of the major constituents of biological macromolecules in living organisms. Many biological processes including protein folding, stability, immune response and receptor activation are regulated by glycosylation. In this work, we optimized a capillary electrophoresis method with capacitively coupled contactless conductivity detection for the separation of eight monosaccharides commonly found in glycoproteins, namely D-glucose, D-galactose, D-mannose, N-acetyl-D-glucosamine, N-acetyl-D-galactosamine, D-fucose, N-acetylneuraminic acid, and D-xylose. A highly alkaline solution of 50 mM sodium hydroxide, 22.5 mM disodium phosphate, and 0.2 mM CTAB (pH 12.4) was used as a background electrolyte in a 10 μm id capillary. To achieve baseline separation of all analytes, a counter-directional pressure of -270 kPa was applied during the separation. The limits of detection of our method were below 7 μg/ml (i.e., 1.5 pg or 1 mg/g protein) and the limits of quantification were below 22 μg/ml (i.e., 5 pg or 3 mg/g protein). As a proof of concept of our methodology, we performed an analysis of monosaccharides released from fetuin glycoprotein by acid hydrolysis. The results show that, when combined with an appropriate pre-concentration technique, the developed method can be used as a monosaccharide profiling tool in glycoproteomics and complement the routinely used LC-MS/MS analysis.
- MeSH
- acetylgalaktosamin MeSH
- acetylglukosamin MeSH
- cetrimonium MeSH
- chromatografie kapalinová MeSH
- elektroforéza kapilární metody MeSH
- elektrolyty chemie MeSH
- fetuiny MeSH
- fosfáty MeSH
- fukosa MeSH
- galaktosa MeSH
- glukosa MeSH
- glykoproteiny chemie MeSH
- hydroxid sodný MeSH
- kyselina N-acetylneuraminová * MeSH
- mannosa MeSH
- monosacharidy * analýza MeSH
- tandemová hmotnostní spektrometrie MeSH
- xylosa MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH