- Klíčová slova
- COVID‐19, Czech Republic, adverse events, batches, vaccine,
- Publikační typ
- časopisecké články MeSH
- MeSH
- chřipka lidská * MeSH
- COVID-19 * prevence a kontrola MeSH
- lidé MeSH
- účinost vakcíny MeSH
- vakcíny proti COVID-19 MeSH
- zdravotní stav MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
- komentáře MeSH
- Názvy látek
- vakcíny proti COVID-19 MeSH
Cellular immunity against SARS-CoV-2 is an important component of the immune response to the virus. At present, two such tests based on interferon-gamma release (interferon-γ release assays, IGRAs) are available-Quan-T-Cell SARS-CoV-2 by EUROIMMUN and T-SPOT.COVID by Oxford Immunotec. In this paper, we compared the results of these two tests in 90 subjects employed at the Public Health Institute Ostrava who had previously undergone COVID-19 infection or were vaccinated against that disease. To the best of our knowledge, this is the first head-to-head comparison of these two tests evaluating T-cell-mediated immunity against SARS-CoV-2. In addition, we also evaluated humoral immunity in the same individuals using the in-house virus neutralization test and IgG ELISA assay. The evaluation yielded similar results for both IGRAs, with Quan-T-Cell appearing to be insignificantly (p = 0.08) more sensitive (all 90 individuals were at least borderline positive) than T-SPOT.COVID (negative results found in five patients). The overall qualitative (presence/absence of immune response) agreement of both tests with virus neutralization test and anti-S IgG was also excellent (close or equal to 100% in all subgroups, with the exception of unvaccinated Omicron convalescents, a large proportion of whom, i.e., four out of six subjects, were IgG negative while at least borderline positive for T-cell-mediated immunity measured by Quan-T). This implies that the evaluation of T-cell-mediated immunity is a more sensitive indicator of immune response than the evaluation of IgG seropositivity. This is true at least for unvaccinated patients with a history of being infected only by the Omicron variant, but also likely for other groups of patients.
- Klíčová slova
- COVID-19, IGRA, SARS-CoV-2, T-cells, cellular immunity, humoral immunity, interferon-gamma release assay,
- Publikační typ
- časopisecké články MeSH
BACKGROUND AND AIMS: Elderly nursing home residents are especially prone to a severe course of SARS-CoV-2 infection. In this study, we aimed to investigate the complex immune response after vaccination depending on the convalescence status and vaccine. METHODS: Sampling took place in September-October 2021. IgG antibodies against spike protein and nucleocapsid protein, the titer of virus neutralization antibodies against delta and (on a subset of patients) omicron, and cellular immunity (interferon-gamma release assay) were tested in nursing home residents vaccinated with Pfizer, Moderna (both 30-31 weeks after the completion of vaccination), or AstraZeneca (23 weeks) vaccines. The prevalence with 95% confidence intervals (CI) was evaluated in Stata version 17. RESULTS: 95.2% (95% CI: 92.5-97.1%) of the 375 participants had positive results of anti-S IgG, 92.8% (95% CI: 89.7-95.2%) were positive in virus neutralization assay against delta, and 89.0% (95% CI: 84.5-92.5%) in the interferon-gamma-releasing assay detecting cellular immunity. Results of the virus neutralization assay against omicron correlated with those against delta but the neutralization capacity was reduced by about half. As expected, the worst results were found for the AstraZeneca vaccine, although the vaccination-to-test period was the shortest for this vaccine. All immune parameters were significantly higher in convalescent residents than in naive residents after vaccination. No case of COVID-19 occurred during the vaccination-to-test period. CONCLUSIONS: A high immune response, especially among vaccinated convalescents (i.e., residents with hybrid immunity), was found in elderly nursing home residents 5-7 months after vaccination against SARS-CoV-2. In view of this, it appears that such residents are much better protected from COVID-19 than those who are only vaccinated and the matter of individual approach to the booster dose in such individuals should be further discussed.
- Klíčová slova
- COVID-19, cellular immunity, elderly nursing home residents, humoral immunity,
- MeSH
- COVID-19 * epidemiologie prevence a kontrola MeSH
- imunita MeSH
- imunoglobulin G MeSH
- lidé MeSH
- pečovatelské domovy MeSH
- SARS-CoV-2 MeSH
- senioři MeSH
- vakcinace MeSH
- vakcíny * MeSH
- Check Tag
- lidé MeSH
- senioři MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH
- Geografické názvy
- Česká republika epidemiologie MeSH
- Názvy látek
- imunoglobulin G MeSH
- vakcíny * MeSH
Data on the effectiveness of arthroscopic arthrolysis and extraction of osteosynthetic material after osteosynthesis of the proximal humerus in patients with persisting problems are rare and insufficient. In this study, we performed arthroscopic arthrolysis and extraction of fixation screws, and, where protruding, extraction of the nail in 34 patients with problems persisting 12 months after osteosynthesis of the proximal humerus using an intramedullary nail. The effectiveness of the treatment was assessed using the Constant-Murley shoulder score and forward flexion difference between the treated arm and the contralateral one. A median increase of 16 points in CMS score and 30 degrees reduction in the arm forward flexion difference was recorded 12 months after the arthroscopy. The improvement was significantly higher in the patient group with intramedullary nail extraction (however, this group had worse pre-operative values and the screw was only extracted where likely to cause problems). The median time to heal was 11 weeks; no serious peri- or post-procedural complications occurred. Mini-invasive arthroscopic arthrolysis combined with extraction of osteosynthetic material proved to be a safe and effective method for treatment of patients after osteosynthesis of the proximal humerus using an intramedullary nail with persisting pain and/or mobility limitation.
- Klíčová slova
- Constant–Murley shoulder score, arthrolysis, arthroscopy, extraction, intramedullary nail, post-operative dysfunction, proximal humerus fracture, screw, shoulder,
- Publikační typ
- časopisecké články MeSH
Background and Objectives: In patients with orbital floor blowout fracture (OFBF), accurate diagnosis of ocular motility disorder is important for decisions about conservative or surgical therapy. However, the accuracy of the traditional test for detecting binocular diplopia/ocular motility disorder using a moving pencil or finger (hereinafter, "finger test") has been generally accepted as correct and has not been subject to scrutiny so far. Hence, its accuracy relative to full orthoptic examination is unknown. Materials and Methods: In this paper, the results of the "finger test" were compared with those derived from a complex examination by orthoptic tests (considered "true" value in patients with OFBF). Results: "Finger test" detected ocular motility disorder in 23% of patients while the full orthoptic examination proved much more efficient, detecting ocular motility disorder in 65% of patients. Lancaster screen test and test with color filters were the most important tests in the battery of the orthoptic tests, capable of identifying 97.7% and 95.3% of patients with ocular motility disorder, respectively. Still, none of the tests were able to correctly detect all patients with ocular motility disorder in itself. Conclusions: As the presence of ocular motility disorder/binocular diplopia is an important indication criterion for the surgical solution of the orbital floor blowout fracture, we conclude that a complex orthoptic evaluation should be always performed in these patients.
- Klíčová slova
- diplopia, maxillofacial surgery, ocular motility disorder, orbit, orbital blowout fractures, orthoptic examination,
- MeSH
- diplopie diagnóza etiologie MeSH
- fraktury očnice * komplikace diagnóza MeSH
- lidé MeSH
- ortoptika MeSH
- poruchy hybnosti oka * MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
BACKGROUND: Antigen testing for SARS-CoV-2 is considered to be less sensitive than the standard reference method - real-time PCR (RT-PCR). It has been suggested that many patients with positive RT-PCR 'missed' by antigen testing might be non-infectious. METHODS: In a real-world high-throughput setting for asymptomatic or mildly symptomatic patients, 494 patients were tested using RT-PCR as well as a single lateral flow antigen test (Ecotest, AssureTech, China). Where the results differed, virus viability was evaluated by cell culture. The test parameters were calculated with RT-PCR and RT-PCR adjusted on viability as reference standards. RESULTS: The overall sensitivity of the used antigen test related to the RT-PCR only was 76.2%, specificity was 97.3%. However, 36 out of 39 patients 'missed' by the antigen test contained no viable virus. After adjusting on that, the sensitivity grew to 97.7% and, more importantly for disease control purposes, the negative predictive value reached 99.2%. CONCLUSIONS: We propose that viability testing should be always performed when evaluating a new antigen test. A well-chosen and validated antigen test provides excellent results in identifying patients who are shedding viable virus (although some caveats still remain) in the real-world high-throughput setting of asymptomatic or mildly symptomatic individuals.
- Klíčová slova
- Covid-19, SARS-CoV-2, antigen testing, sensitivity, virus shedding, virus viability,
- MeSH
- antigeny virové MeSH
- COVID-19 * MeSH
- lidé MeSH
- SARS-CoV-2 MeSH
- senzitivita a specificita MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH
- Geografické názvy
- Čína MeSH
- Názvy látek
- antigeny virové MeSH
Many studies reported good performance of nasopharyngeal swab-based antigen tests for detecting SARS-CoV-2-positive individuals; however, studies independently evaluating the quality of antigen tests utilizing anterior nasal swabs or saliva swabs are still rare, although such tests are widely used for mass testing. In our study, sensitivities, specificities and predictive values of seven antigen tests for detection of SARS-CoV-2 (one using nasopharyngeal swabs, two using anterior nasal swabs and four using saliva) were evaluated. In a setting of a high-capacity testing center, nasopharyngeal swabs for quantitative PCR (qPCR) were taken and, at the same time, antigen testing was performed in accordance with manufacturers' instructions for the respective tests. In samples where qPCR and antigen tests yielded different results, virus culture was performed to evaluate the presence of the viable virus. Sensitivities and specificities of individual tests were calculated using both qPCR and qPCR corrected for viability as the reference. In addition, calculations were also performed for data categorized according to the cycle threshold and symptomatic status. The test using nasopharyngeal swabs yielded the best results (sensitivity of 80.6% relative to PCR and 91.2% when corrected for viability) while none of the remaining tests (anterior nasal swab or saliva-based tests) came even close to the WHO criteria for overall sensitivity. Hence, we advise caution when using antigen tests with alternative sampling methods without independent validation.
- Klíčová slova
- COVID-19, SARS-CoV-2, anterior nasal swab, evaluation, qPCR, rapid antigen tests, saliva, virus culture,
- Publikační typ
- časopisecké články MeSH
Antigen testing for SARS-CoV-2 (AGT) is generally considered inferior to RT-PCR testing in terms of sensitivity. However, little is known about the infectiousness of RT-PCR positive patients who pass undetected by AGT. In a screening setting for mildly symptomatic or asymptomatic patients with high COVID-19 prevalence (30-40%), 1141 patients were tested using one of five AGTs and RT-PCR. Where the results differed, virus viability in the samples was tested on cell culture (CV-1 cells). The test battery included AGTs by JOYSBIO, Assure Tech, SD Biosensor, VivaChek Biotech and NDFOS. Sensitivities of the ATGs compared to RT-PCR ranged from 42% to 76%. The best test yielded a 76% sensitivity, 97% specificity, 92% positive, and 89% negative predictive values, respectively. However, in the best performing ATG tests, almost 90% of samples with "false negative" AGT results contained no viable virus. Corrected on the virus viability, sensitivities grew to 81-97% and, with one exception, the tests yielded high specificities >96%. Performance characteristics of the best test after adjustment were 96% sensitivity, 97% specificity, 92% positive, and 99% negative predictive values (high prevalence population). We, therefore, believe that virus viability should be considered when assessing the AGT performance. Also, our results indicate that a well-performing antigen test could in a high-prevalence setting serve as an excellent tool for identifying patients shedding viable virus. We also propose that the high proportion of RT-PCR-positive samples containing no viable virus in the group of "false negatives" of the antigen test should be further investigated with the aim of possibly preventing needless isolation of such patients.
- Klíčová slova
- COVID-19, RT-PCR, SARS-CoV-2, antigen testing, infectiousness, viability,
- MeSH
- antigeny virové analýza MeSH
- COVID-19 diagnóza imunologie MeSH
- dospělí MeSH
- falešně negativní reakce MeSH
- lidé středního věku MeSH
- lidé MeSH
- mikrobiální viabilita * MeSH
- plošný screening MeSH
- SARS-CoV-2 imunologie MeSH
- senzitivita a specificita MeSH
- sérologické testy metody MeSH
- testování na COVID-19 průkazem nukleové kyseliny MeSH
- testování na COVID-19 metody MeSH
- Check Tag
- dospělí MeSH
- lidé středního věku MeSH
- lidé MeSH
- mužské pohlaví MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- Názvy látek
- antigeny virové MeSH