Invasive bilirubin measurements remain the gold standard for the diagnosis and treatment of infants with severe neonatal hyperbilirubinemia. The present paper describes different methods currently available to assess hyperbilirubinemia in newborn infants. Novel point-of-care bilirubin measurement methods, such as the BiliSpec and the Bilistick, would benefit many newborn infants, especially in low-income and middle-income countries where the access to costly multi-analyzer in vitro diagnostic instruments is limited. Total serum bilirubin test results should be accurate within permissible limits of measurement uncertainty to be fit for clinical purposes. This implies correct implementation of internationally endorsed reference measurement systems as well as participation in external quality assessment programs. Novel analytic methods may, apart from bilirubin, include the determination of bilirubin photoisomers and bilirubin oxidation products in blood and even in other biological matrices. IMPACT: Key message: Bilirubin measurements in blood remain the gold standard for diagnosis and treatment of severe neonatal hyperbilirubinemia (SNH). External quality assessment (EQA) plays an important role in revealing inaccuracies in diagnostic bilirubin measurements. What does this article add to the existing literature? We provide analytic performance data on total serum bilirubin (TSB) as measured during recent EQA surveys. We review novel diagnostic point-of-care (POC) bilirubin measurement methods and analytic methods for determining bilirubin levels in biological matrices other than blood. Impact: Manufacturers should make TSB test results traceable to the internationally endorsed total bilirubin reference measurement system and should ensure permissible limits of measurement uncertainty.
- MeSH
- bilirubin krev MeSH
- biologické markery krev MeSH
- lidé MeSH
- novorozenec MeSH
- novorozenecká hyperbilirubinemie krev diagnóza terapie MeSH
- novorozenecká žloutenka krev diagnóza terapie MeSH
- novorozenecký screening * MeSH
- point of care testing * MeSH
- prediktivní hodnota testů MeSH
- prognóza MeSH
- reprodukovatelnost výsledků MeSH
- stupeň závažnosti nemoci MeSH
- upregulace MeSH
- Check Tag
- lidé MeSH
- novorozenec MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH
- přehledy MeSH
- Názvy látek
- bilirubin MeSH
- biologické markery MeSH
Severe neonatal hyperbilirubinemia (SNH) is a serious condition that occurs worldwide. Timely recognition with bilirubin determination is key in the management of SNH. Visual assessment of jaundice is unreliable. Fortunately, transcutaneous bilirubin measurement for screening newborn infants is routinely available in many hospitals and outpatient settings. Despite a few limitations, the use of transcutaneous devices facilitates early recognition and appropriate management of neonatal jaundice. Unfortunately, however, advanced and often costly screening modalities are not accessible to everyone, while there is an urgent need for inexpensive yet accurate instruments to assess total serum bilirubin (TSB). In the near future, novel icterometers, and in particular optical bilirubin estimates obtained with a smartphone camera and processed with a smartphone application (app), seem promising methods for screening for SNH. If proven reliable, these methods may empower outpatient health workers as well as parents at home to detect jaundice using a simple portable device. Successful implementation of ubiquitous bilirubin screening may contribute substantially to the reduction of the worldwide burden of SNH. The benefits of non-invasive bilirubin screening notwithstanding, any bilirubin determination obtained through non-invasive screening must be confirmed by a diagnostic method before treatment. IMPACT: Key message: Screening methods for neonatal hyperbilirubinemia facilitate early recognition and timely treatment of severe neonatal hyperbilirubinemia (SNH). Any bilirubin screening result obtained must be confirmed by a diagnostic method. What does this article add to the existing literature? Data on optical bilirubin estimation are summarized. Niche research strategies for prevention of SNH are presented. Impact: Transcutaneous screening for neonatal hyperbilirubinemia contributes to the prevention of SNH. A smartphone application with optical bilirubin estimation seems a promising low-cost screening method, especially in low-resource settings or at home.
- MeSH
- bilirubin krev MeSH
- biologické markery krev MeSH
- časná diagnóza MeSH
- chytrý telefon MeSH
- lidé MeSH
- mobilní aplikace MeSH
- novorozenec MeSH
- novorozenecká hyperbilirubinemie krev diagnóza terapie MeSH
- novorozenecká žloutenka krev diagnóza terapie MeSH
- novorozenecký screening * přístrojové vybavení MeSH
- prediktivní hodnota testů MeSH
- prognóza MeSH
- reprodukovatelnost výsledků MeSH
- stupeň závažnosti nemoci MeSH
- upregulace MeSH
- Check Tag
- lidé MeSH
- novorozenec MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH
- přehledy MeSH
- Názvy látek
- bilirubin MeSH
- biologické markery MeSH
Neonatal hyperbilirubinemia or jaundice is associated with kernicterus, resulting in permanent neurological damage or even death. Conventional phototherapy does not prevent hyperbilirubinemia or eliminate the need for exchange transfusion. Here we investigated the potential of therapeutic bile acids ursodeoxycholic acid (UDCA) and obeticholic acid (OCA, 6-α-ethyl-CDCA), a farnesoid-X-receptor (FXR) agonist, as preventive treatment options for neonatal hyperbilirubinemia using the hUGT1*1 humanized mice and Ugt1a-deficient Gunn rats. Treatment of hUGT1*1 mice with UDCA or OCA at postnatal days 10-14 effectively decreased bilirubin in plasma (by 82% and 62%) and brain (by 72% and 69%), respectively. Mechanistically, our findings indicate that these effects are mediated through induction of protein levels of hUGT1A1 in the intestine, but not in liver. We further demonstrate that in Ugt1a-deficient Gunn rats, UDCA but not OCA significantly decreases plasma bilirubin, indicating that at least some of the hypobilirubinemic effects of UDCA are independent of UGT1A1. Finally, using the synthetic, non-bile acid, FXR-agonist GW4064, we show that some of these effects are mediated through direct or indirect activation of FXR. Together, our study shows that therapeutic bile acids UDCA and OCA effectively reduce both plasma and brain bilirubin, highlighting their potential in the treatment of neonatal hyperbilirubinemia.
- MeSH
- bilirubin krev MeSH
- ileum účinky léků metabolismus MeSH
- isoxazoly farmakologie MeSH
- játra účinky léků metabolismus MeSH
- krysa rodu Rattus MeSH
- kyselina chenodeoxycholová analogy a deriváty terapeutické užití MeSH
- kyselina ursodeoxycholová terapeutické užití MeSH
- myši MeSH
- novorozenecká hyperbilirubinemie krev farmakoterapie MeSH
- potkani Gunn MeSH
- receptory cytoplazmatické a nukleární agonisté metabolismus MeSH
- výsledek terapie MeSH
- žlučové kyseliny a soli terapeutické užití MeSH
- zvířata MeSH
- Check Tag
- krysa rodu Rattus MeSH
- myši MeSH
- zvířata MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH
- Názvy látek
- bilirubin MeSH
- farnesoid X-activated receptor MeSH Prohlížeč
- GW 4064 MeSH Prohlížeč
- isoxazoly MeSH
- kyselina chenodeoxycholová MeSH
- kyselina ursodeoxycholová MeSH
- obeticholic acid MeSH Prohlížeč
- receptory cytoplazmatické a nukleární MeSH
- žlučové kyseliny a soli MeSH
BACKGROUND: The action spectrum for bilirubin photodegradation has been intensively studied. However, questions still remain regarding which light wavelength most efficiently photodegrades bilirubin. In this study, we determined the in vitro effects of different irradiation wavelength ranges on bilirubin photodegradation. METHODS: In our in vitro method, normalized absolute irradiance levels of 4.2 × 1015 photons/cm2/s from light-emitting diodes (ranging from 390-530 nm) and 10-nm band-pass filters were used to irradiate bilirubin solutions (25 mg/dL in 4% human serum albumin). Bilirubin and its major photoisomer concentrations were determined; the half-life time of bilirubin (t1/2) was calculated for each wavelength range, and the spectral characteristics for bilirubin photodegradation products were obtained for key wavelengths. RESULTS: The in vitro photodegradation of bilirubin at 37 °C decreased linearly as the wavelength was increased from 390 to 500 nm with t1/2 decreasing from 63 to 17 min, respectively. At 460 ± 10 nm, a significantly lower rate of photodegradation and thus higher t1/2 (31 min) than that at 500 nm (17 min) was demonstrated. CONCLUSION: In our system, the optimum bilirubin photodegradation and lumirubin production rates occurred between 490 and 500 nm. Spectra shapes were remarkably similar, suggesting that lumirubin production was the major process of bilirubin photodegradation.
- MeSH
- bilirubin analogy a deriváty krev chemie účinky záření MeSH
- fotolýza účinky záření MeSH
- fototerapie metody MeSH
- isomerie MeSH
- lidé MeSH
- lidský sérový albumin chemie účinky záření MeSH
- novorozenec MeSH
- novorozenecká hyperbilirubinemie krev terapie MeSH
- spektrofotometrie MeSH
- světlo * MeSH
- techniky in vitro MeSH
- Check Tag
- lidé MeSH
- novorozenec MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH
- Názvy látek
- bilirubin MeSH
- lidský sérový albumin MeSH
- lumirubin MeSH Prohlížeč
Therapies to prevent severe neonatal unconjugated hyperbilirubinemia and kernicterus are phototherapy and, in unresponsive cases, exchange transfusion, which has significant morbidity and mortality risks. Neurotoxicity is caused by the fraction of unconjugated bilirubin not bound to albumin (free bilirubin, Bf). Human serum albumin (HSA) administration was suggested to increase plasma bilirubin-binding capacity. However, its clinical use is infrequent due to difficulties to address its potential preventive and curative benefits, and to the absence of reliable markers to monitor bilirubin neurotoxicity risk. We used a genetic mouse model of unconjugated hyperbilirubinemia showing severe neurological impairment and neonatal lethality. We treated mutant pups with repeated HSA administration since birth, without phototherapy application. Daily intraperitoneal HSA administration completely rescued neurological damage and lethality, depending on dosage and administration frequency. Albumin infusion increased plasma bilirubin-binding capacity, mobilizing bilirubin from tissues to plasma. This resulted in reduced plasma Bf, forebrain and cerebellum bilirubin levels. We showed that, in our experimental model, Bf is the best marker to determine the risk of developing neurological damage. These results support the potential use of albumin administration in severe acute hyperbilirubinemia conditions to prevent or treat bilirubin neurotoxicity in situations in which exchange transfusion may be required.
- MeSH
- bilirubin krev MeSH
- fototerapie metody MeSH
- lidé MeSH
- modely nemocí na zvířatech MeSH
- mozeček účinky léků MeSH
- myši MeSH
- nemoci nervového systému etiologie prevence a kontrola MeSH
- novorozenecká hyperbilirubinemie krev komplikace MeSH
- novorozenecká žloutenka krev komplikace MeSH
- sérový albumin aplikace a dávkování MeSH
- zvířata MeSH
- Check Tag
- lidé MeSH
- myši MeSH
- zvířata MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH
- Názvy látek
- bilirubin MeSH
- sérový albumin MeSH